Giovanni Nicoletti

Prof. Dr. Giovanni Nicoletti

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2004 in Plastic and Reconstructive Surgery
Verified
Journal Article
Closed access
GNGiovanni Nicoletti
Giovanni Nicoletti
DSDavid S. Soutar
David S. Soutar
MJMary S. Jackson
Mary S. Jackson
AWAlan A. Wrench
Alan A. Wrench
GRGerry Robertson
Gerry Robertson
One hundred ninety-six patients treated for oral cancer between 1992 and 1999 self-scored their speech, chewing, and swallowing using a new self-questionnaire (Functional Intraoral Glasgow Scale) developed at Canniesburn Hospital, Glasgow, to assess the functional efficiency of patients treated for intraoral cancer. The patients were distributed into 12 homogeneous groups, according to the site and size of surgical resection, carefully mapped out on standard diagrams of the oral cavity. The functional outcome for chewing and swallowing was correlated to the site and size of resected tissue, to the reconstruction modality, and to radiotherapy and compared with the speech quality. The general trend is very similar for both chewing and swallowing; the smaller the resections, the better the functional outcome. Chewing was mostly affected by resections of the floor of the mouth, whereas swallowing was mostly affected by demolition of the base of the tongue and of the retromolar trigone. Speech showed a better postoperative recovery than chewing and swallowing. The reconstruction modality did not influence the eventual outcome for either function. Radiotherapy in combination with surgery is a negative functional prognostic factor. A correlation between site and size of excision and functional outcome is presented using color multiple-view diagrams for immediate appreciation to identify positive and negative prognostic factors.

1 January 2004 in Plastic and Reconstructive Surgery
Verified
Journal Article
Closed access
GNGiovanni Nicoletti
Giovanni Nicoletti
DSDavid S. Ch.M. Soutar
David S. Ch.M. Soutar
MJMary S. L.C.S.T. Jackson
Mary S. L.C.S.T. Jackson
AWAlan A. B.Sc.(Hons.) Wrench
Alan A. B.Sc.(Hons.) Wrench
GRGerry Ph.D. Robertson
Gerry Ph.D. Robertson
CRChris B.Sc. Robertson
Chris B.Sc. Robertson
In 1992, a personal computer–based workstation for speech-digitized analysis was developed in conjunction with Canniesburn Hospital and Edinburgh University to measure all dispersion in speech after surgery for oral cancer. The voices of 196 patients with tumor of the oral cavity were recorded preoperatively and postoperatively. Surgical resection was carefully mapped out on standard diagrams of the oral cavity. Patients’ recordings were assessed for conversational understandability by two referees. Patients also self-scored their speech using the Functional Intraoral Glasgow Scale self-questionnaire. Many patients had similar if not identical resections; therefore, 12 homogeneous groups were identified. Functional outcome for speech was correlated with the site and size of resected tissue and with the reconstruction modalities. The original association of an objective, computer-based tool and two subjective assessment tools proved to be the most suitable investigation method for speech. The general pattern was for consistently better speech quality with smaller excisions. The reconstruction modalities did not seem to influence the overall speech quality, as it was related mainly to the extent of surgical demolition. The authors present a detailed correlation between site and size of excision and functional outcome using color multiple-view diagrams for immediate appreciation. Positive and negative prognostic factors were identified in surgery for oral cancer.

24 June 2014 in Journal of Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Open access
PDF file
GNGiovanni Nicoletti
Giovanni Nicoletti
FBFederica Brenta
Federica Brenta
MBMariella Bleve
Mariella Bleve
TPTommaso Pellegatta
Tommaso Pellegatta
AMAlberto Malovini
Alberto Malovini
PPPaola Perugini
Paola Perugini
The aim of the study was an objective in vivo assessment of skin properties after reconstruction with two artificial dermal substitutes, Integra® and Hyalomatrix®. Twenty‐seven patients underwent reconstruction of 36 skin‐loss sites with full‐thickness skin graft, split‐thickness skin graft, Hyalomatrix® bioengineered skin substitute and sequential split‐thickness skin graft and Integra® bioengineered skin substitute and sequential split‐thickness skin graft. Objective assessments were carried out using three instrumental devices: Multi Probe Adapter System MPA; 22 MHz ultrasound skin scan; and Primos Pico for a three‐dimensional (3D) skin scan. The skin parameters under study in our sample were: corneometry, transepidermal water loss, elastometry, colorimetry, skin thickness and 3D skin surface pattern. A skin reconstruction with Hyalomatrix seemed to most closely approach the hydration, transepidermal water loss and skin surface 3D pattern of normal skin. A skin reconstruction with Integra seemed to demonstrate the best skin colour feature and elastic properties. Although no statistically significant differences were observed, the descriptive analysis of the outcomes might suggest a better cell regulation, regenerated extracellular matrix and neoangiogenesis with the use of Hyalomatrix, and the formation of a more elastic regenerated dermis, with overall better physical, mechanical and optical properties, with the use of Integra. © 2014 The Authors. Journal of Tissue Engineering and Regenerative Medicine published by John Wiley & Sons Ltd.

20 May 2010 in International Wound Journal
Verified
Journal Article
Closed access
PDF file
SSSilvia Scevola
Silvia Scevola
GNGiovanni Nicoletti
Giovanni Nicoletti
FBFederica Brenta
Federica Brenta
PIPaola Isernia
Paola Isernia
MMmarcello maestri
marcello maestri
AFAngela Faga
Angela Faga

24 December 2015 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
FFFlavia Fontana
Flavia Fontana
MMMichela Mori
Michela Mori
FRFederica Riva
Federica Riva
EMErmei Mäkilä
Ermei Mäkilä
DLDongfei Liu
Dongfei Liu
Hélder SantosHélder Santos
Hélder Santos

1 January 2018 in Indian Journal of Plastic Surgery
Verified
Journal Article
Open access
PDF file
GNGiovanni Nicoletti
Giovanni Nicoletti
MTMarco Mario Tresoldi
Marco Mario Tresoldi
AMAlberto Malovini
Alberto Malovini
MVMarco Visaggio
Marco Visaggio
AFAngela Faga
Angela Faga
SSSilvia Scevola
Silvia Scevola
Background: Dermal substitutes are currently largely used for the treatment of huge skin loss in patients in critical general health conditions, for the treatment of severe burns and to promote the healing process in chronic wounds. Aims: The authors performed a retrospective assessment of their experience with bioengineered skin to possibly identify the most appropriate clinical indication and management for each substitute. Materials and Methods: The study involved 109 patients with 127 skin defects repaired with dermal substitutes over a 9 years period, from 2007 to 2016. Hyalomatrix® was used in 63 defects, whereas Integra® and Nevelia® were used in 56 and 8 defects, respectively. Results: The statistical analysis failed to reveal a correlation between the choice of a specific dermal substitute and any possible clinical variable except in the soft-tissue defects of the scalp where Hyalomatrix® was electively used. Conclusions: In the authors’ experience, the scalp defects followed a radical excision of skin tumours that included the periosteum. Here, the preliminary cover with a hyaluronan three-dimensional scaffold constantly allowed for the regeneration of a derma-like layer with a rich vascular network fit for supporting a split-thickness skin graft. Nevertheless, the authors still prefer Integra® when the goal is a better cosmetic outcome and Hyalomatrix® when a faster wound healing is required, especially in the management of deep wounds where the priority is a fast obliteration with a newly formed tissue with a rich blood supply. However, these clinical indications still are anecdotally based.