Objective: Although lung cancer screening trials have showed the efficacy of computed tomography to decrease mortality compared with chest radiography, the two are widely taken as different kinds of clinical practices. Artificial intelligence can improve outcomes by detecting lung tumors in chest radiographs. Currently, artificial intelligence is used as an aid for physicians to interpret radiograms, but with the future evolution of artificial intelligence, it may become a modality that replaces physicians. Therefore, in this study, we investigated the current situation of lung cancer diagnosis by artificial intelligence. Methods: In total, we recruited 174 consecutive patients with malignant pulmonary tumors who underwent surgery after chest radiography that was checked by artificial intelligence before surgery. Artificial intelligence diagnoses were performed using the medical image analysis software EIRL X-ray Lung Nodule version 1.12, (LPIXEL Inc., Tokyo, Japan). Results: The artificial intelligence determined pulmonary tumors in 90 cases (51.7% for all patients and 57.7% excluding 18 patients with adenocarcinoma in situ). There was no significant difference in the detection rate by the artificial intelligence among histological types. All eighteen cases of adenocarcinoma in situ were not detected by either the artificial intelligence or the physicians. In a univariate analysis, the artificial intelligence could detect cases with larger histopathological tumor size (p < 0.0001), larger histopathological invasion size (p < 0.0001), and higher maximum standardized uptake values of positron emission tomography-computed tomography (p < 0.0001). In a multivariate analysis, detection by AI was significantly higher in cases with a large histopathological invasive size (p = 0.006). In 156 cases excluding adenocarcinoma in situ, we examined the rate of artificial intelligence detection based on the tumor site. Tumors in the lower lung field area were less frequently detected (p = 0.019) and tumors in the middle lung field area were more frequently detected (p = 0.014) compared with tumors in the upper lung field area. Conclusions: Our study showed that using artificial intelligence, the diagnosis of tumor-associated findings and the diagnosis of areas that overlap with anatomical structures is not satisfactory. While the current standing of artificial intelligence diagnostics is to assist physicians in making diagnoses, there is the possibility that artificial intelligence can substitute for humans in the future. However, artificial intelligence should be used in the future as an enhancement, to aid physicians in the role of a radiologist in the workflow.
Introduction of the robotic stapler has allowed robotic lobectomy to be performed from a surgical console in complete autonomy. The robotic stapler fits a 12-mm port, which is larger than the standard 8-mm port and increases the risk of postoperative pain. However, in many cases, to cover all possible angles of approach, two 12-mm ports are preferably used. However, limiting instrument inventory and simplifying surgical procedures are also desirable to reduce costs. In a multicenter study, we assessed the feasibility of robotic lobectomy with a single type of robotic stapler [SureForm45 Curved-Tip (SF45C); Intuitive Surgical Inc.] inserted through one 12-mm port placed at the anterior tip of the lower intercostal space. We also investigated the potential cost savings of using an additional 60-mm stapler for interlobar division. A total of 135 lobectomy cases were enrolled. In all cases, all stapling procedures were completed using the SF45C inserted from the designated 12-mm port. We found that it was potentially less expensive to use the SureForm60 stapler if more than six SF45C reloads were needed for interlobar division. However, in our series, only 1 case (0.7%) met this requirement. The use of a single type of stapler from one 12-mm port in a robotic lobectomy is technically feasible. This approach may be expected to allow for surgical simplification, minimize the risk of postoperative pain, and reduce inventory costs.
Objectives: The introduction of the robotic stapler has made it possible to perform a robotic lobectomy from the console in complete autonomy. The robotic stapler fits a 12-mm port, which is larger than the standard 8-mm port and increases the risk of postoperative neuralgia. However, in many cases, to cover all possible angles of approach, two 12-mm ports are preferably placed. Meanwhile, limiting instruments and simplifying surgical procedures are also required to reduce costs. Methods: We assessed the feasibility of robotic lobectomy with a single type of robotic stapler inserted through one 12-mm port placed at the anterior tip of the lower intercostal space, and applied a SureForm45 Curved-Tip (Intuitive Surgical Inc., Sunnyvale, CA, USA) in a multicenter setting. We also investigated the potential cost-saving of using an additional 60-mm stapler for interlobar division. Results: A total of 135 lobectomy cases were enrolled. In all the cases, all stapling procedures were completed using a SureForm45 Curved-Tip inserted from the designated 12-mm port. We found that it was less expensive to use the SureForm60 if more than six SureForm45 Curved-Tips were needed for interlobar division. Nevertheless, in our series, only one case (0.7%) met this requirement. Conclusion: The use of a single type of stapler from one 12-mm port in a robotic lobectomy is a technically feasible approach, which expected to allow for surgical simplification, minimize the risk of neuralgia, and reduce inventory costs.