Introduction: Laboratory-acquired infections (LAIs) from exposure to infectious biological pathogens during laboratory operations present ongoing challenges despite modern biosafety measures. Notably, LAIs attributed to inhaling infectious aerosols continue to occur. Objective: This review aims to enhance understanding of the risks of LAIs associated with infectious aerosols. The first objective of this review is to summarize studies that have characterized the potential for accidental aerosol generation in biological laboratories and to synthesize these findings. The second objective is to examine past LAI incidents involving infectious aerosol exposure to identify knowledge gaps. Methods: A literature review using PubMed and Google Scholar databases with relevant keywords was performed. The results were screened to identify studies that reported LAIs related to aerosol exposures. Thirty-eight articles pertaining to LAIs involving infectious aerosol exposures from an initial pool of 63 articles were identified. Discussion and Conclusions: This review underscores the need for comprehensive safety protocols to mitigate risks associated with LAIs due to aerosol generation. It identifies critical gaps in understanding aerosol dynamics, such as particle size distribution and the influence of laboratory automation. The review also highlights the inadequacy of current LAI reporting practices, advocating for improved documentation and standardized methods to enhance biosafety in laboratory settings.
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and resulting COVID-19 (coronavirus disease 2019) pandemic have required mass diagnostic testing, often taking place in testing sites within hospitals, clinics, or at satellite locations. To establish the potential of SARS-CoV-2 aerosol transmission and to identify junctures during testing that result in increased viral exposure, aerosol and surface samples were examined for the presence of SARS-CoV-2 RNA from locations within Nebraska Medicine COVID-19 testing and vaccine clinics. Aerosols containing SARS-CoV-2 RNA detected within clinics suggest viral shedding from infected individuals. SARS-CoV-2 RNA detection in aerosol samples was shown to correlate with clinic operation and patient infection, as well as with community infection findings. Additionally, SARS-CoV-2 RNA was detected in surface samples collected from clinics. The presence of SARS-CoV-2 RNA in aerosols in these clinics supports the continued use of respiratory protection and sanitization practices for healthcare workers, and other workers with public facing occupations.
Sin Nombre virus (SNV) is the main causative agent of hantavirus cardiopulmonary syndrome (HCPS) in North America. SNV is transmitted via environmental biological aerosols (bioaerosols) produced by infected deer mice (Peromyscus maniculatus). It is similar to other viruses that have environmental transmission routes rather than a person-to-person transmission route, such as avian influenza (e.g., H5N1) and Lassa fever. Despite the lack of person-to-person transmission, these viruses cause a significant public health and economic burden. However, due to the lack of targeted pharmaceutical preventatives and therapeutics, the recommended approach to prevent SNV infections is to avoid locations that have a combination of low foot traffic, receive minimal natural sunlight, and where P. maniculatus may be found nesting. Consequently, gaining insight into the SNV bioaerosol decay profile is fundamental to the prevention of SNV infections. The Biological Aerosol Reaction Chamber (Bio-ARC) is a flow-through system designed to rapidly expose bioaerosols to environmental conditions (ozone, simulated solar radiation (SSR), humidity, and other gas phase species at stable temperatures) and determine the sensitivity of those particles to simulated ambient conditions. Using this system, we examined the bioaerosol stability of SNV. The virus was found to be susceptible to both simulated solar radiation and ozone under the tested conditions. Comparisons of decay between the virus aerosolized in residual media and in a mouse bedding matrix showed similar results. This study indicates that SNV aerosol particles are susceptible to inactivation by solar radiation and ozone, both of which could be implemented as effective control measures to prevent disease in locations where SNV is endemic.
Inhalation RNA therapy offers to transform treatment of pulmonary diseases, yet mucus trapping, immune clearance, and navigation of heterogeneous lung tissue architecture still prevents RNA from reaching its target cells. Here, we develop perfluorocarbon (PFC) RNA nanocapsules that show negligible immune clearance, minimal inflammatory response, and efficient mucus transport, while passively homing to lung epithelial and tumor cells. After a single aerosolized dose in orthotopic lung metastasis model, more than 60% of tumor cells and most type II alveolar and bronchial epithelial cells internalized the nanocapsules, with observed pulmonary retention exceeding 48 h. The nanocapsule provoke negligible cytokine release, enabling repeated dosing. Treatment with therapeutic miR34-a suppresses metastatic outgrowth, potentiates anti-tumor immunity, and almost doubles median survival relative to control paclitaxel chemotherapy. By combining unique PFC disposition with RNA versatility, the delivery platform overcomes the main biological barriers for inhalable RNA medicines and opens a translatable path for treating diverse pulmonary diseases.
During the COVID-19 pandemic, meatpacking workers were disproportionately affected by disease. Large outbreaks at meatpacking facilities resulted in loss of life and threatened the well-being of workers across the globe. Much work was done throughout the pandemic to understand and prevent these outbreaks. This study combined ventilation system evaluation and measurement of human-generated respiratory aerosol to investigate and identify areas of highest risk for disease transmission. These findings confirm that improved ventilation reduces exposure to human-generated aerosols in meatpacking facilities, including those that may contain infectious agents, such as SARS-CoV-2. This study suggests areas of greatest risk are likely areas where workers break from work, such as cafeterias and locker rooms, where ventilation is poorer, use of face masks is reduced, and people congregate. Furthermore, these findings also suggest that ventilation of production areas of the plant, which have been designed for food safety, is sufficient to reduce exposures and likely contributes to reduced transmission in those spaces. Based on these findings, two controls should be prioritized to minimize the likelihood of exposure to potentially infectious aerosols: (1) improving mechanical ventilation and/or adding mitigation strategies such as media filters, germicidal ultraviolet, and other air cleaning technology and (2) applying administrative practices that minimize large congregations of people in poorly ventilated spaces. Importantly, this work demonstrates a method for in situ measurements of human-generated particles that can be used more broadly to understand exposure and risk in various occupied spaces.
21 July 2026 in Applied and Environmental Microbiology
Infectious viral aerosols outside primary containment represent a profound yet undercharacterized occupational biohazard in microbiological environments. While the role of viral aerosols in laboratory-acquired infections is widely acknowledged, quantitative data on the concentration and size distribution of viral aerosols generated during common laboratory workflows remain limited. This study addresses these gaps by using a controlled chamber to characterize the generation of aerosols containing either a physical tracer, sodium fluorescein, or a viral pathogen surrogate, bacteriophage MS2. By integrating aerodynamic particle sizing with cascade impaction and filtered collection, we quantified the mass, number, and infectivity of aerosols emitted during both routine laboratory procedures and simulated accidental releases. These results reveal that every evaluated action generated measurable aerosols spanning multiple particle sizes. Importantly, all MS2-based actions produced infectious aerosols within the respirable size fraction, confirming that routine benchtop pipetting actions yield viral aerosols. These data provide an empirical foundation for evidence-based risk assessments. IMPORTANCE: Laboratory-acquired viral infections have occurred following routine laboratory procedures in which no distinct accident is recorded, suggesting unrecognized release and inhalation of infectious virus. This research provides a quantitative analysis of these aerosols using a non-pathogenic viral surrogate, MS2, to model viral pathogens. We demonstrate that common laboratory tasks, such as pipetting or handling culture plates, generate respirable infectious aerosols that can bypass standard precautions when outside primary containment. By defining the size and infectious load of these aerosols, this work enables biosafety professionals to transition from qualitative assumptions to data-driven safety protocols, ultimately protecting the personnel responsible for viral pathogen research.