Fraser Young

Dr. Fraser Young


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2022 in Sports Medicine
Verified
Journal Article
Open access
PDF file
RMRachel Mason
Rachel Mason
LPLiam T. Pearson-Noseworthy
Liam T. Pearson-Noseworthy
GBGillian Barry
Gillian Barry
FYFraser Young
Fraser Young
OLOisin Lennon
Oisin Lennon
SSSamuel Stuart
Samuel Stuart
Background: Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analysis of running mechanics in any environment. Objective measurement of running gait is an important (clinical) tool for injury assessment and provides measures that can be used to enhance performance.Objectives: We aimed to systematically review the available literature investigating how wearable technology is being used for running gait analysis in adults.Methods: A systematic search of the literature was conducted in the following scientific databases: PubMed, Scopus, Web of Science and SPORTDiscus. Information was extracted from each included article regarding the type of study, participants, protocol, wearable device(s), main outcomes/measures, analysis and key findings.Results: A total of 131 articles were reviewed: 56 investigated the validity of wearable technology, 22 examined the reliability and 77 focused on applied use. Most studies used inertial measurement units (n = 62) [i.e. a combination of accelerometers, gyroscopes and magnetometers in a single unit] or solely accelerometers (n = 40), with one using gyroscopes alone and 31 using pressure sensors. On average, studies used one wearable device to examine running gait. Wearable locations were distributed among the shank, shoe and waist. The mean number of participants was 26 (± 27), with an average age of 28.3 (± 7.0) years. Most studies took place indoors (n = 93), using a treadmill (n = 62), with the main aims seeking to identify running gait outcomes or investigate the effects of injury, fatigue, intrinsic factors (e.g. age, sex, morphology) or footwear on running gait outcomes. Generally, wearables were found to be valid and reliable tools for assessing running gait compared to reference standards.Conclusions: This comprehensive review highlighted that most studies that have examined running gait using wearable sensors have done so with young adult recreational runners, using one inertial measurement unit sensor, with participants running on a treadmill and reporting outcomes of ground contact time, stride length, stride frequency and tibial acceleration. Future studies are required to obtain consensus regarding terminology, protocols for testing validity and the reliability of devices and suitability of gait outcomes.Clinical Trial Registration: CRD42021235527.

19 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
FYFraser Young
Fraser Young
RMRachel Mason
Rachel Mason
RMRosie Morris
Rosie Morris
SSSamuel Stuart
Samuel Stuart
Alan GodfreyAlan Godfrey
Alan Godfrey
Walking/gait quality is a useful clinical tool to assess general health and is now broadly described as the sixth vital sign. This has been mediated by advances in sensing technology, including instrumented walkways and three-dimensional motion capture. However, it is wearable technology innovation that has spawned the highest growth in instrumented gait assessment due to the capabilities for monitoring within and beyond the laboratory. Specifically, instrumented gait assessment with wearable inertial measurement units (IMUs) has provided more readily deployable devices for use in any environment. Contemporary IMU-based gait assessment research has shown evidence of the robust quantifying of important clinical gait outcomes in, e.g., neurological disorders to gather more insightful habitual data in the home and community, given the relatively low cost and portability of IMUs. The aim of this narrative review is to describe the ongoing research regarding the need to move gait assessment out of bespoke settings into habitual environments and to consider the shortcomings and inefficiencies that are common within the field. Accordingly, we broadly explore how the Internet of Things (IoT) could better enable routine gait assessment beyond bespoke settings. As IMU-based wearables and algorithms mature in their corroboration with alternate technologies, such as computer vision, edge computing, and pose estimation, the role of IoT communication will enable new opportunities for remote gait assessment.

6 September 2022 in Frontiers in Sports and Active Living
Verified
Journal Article
Open access
FYFraser Young
Fraser Young
RMRachel Mason
Rachel Mason
CWConor Wall
Conor Wall
RMRosie Morris
Rosie Morris
SSSamuel Stuart
Samuel Stuart
Alan GodfreyAlan Godfrey
Alan Godfrey
Gait assessment is essential to understand injury prevention mechanisms during running, where high-impact forces can lead to a range of injuries in the lower extremities. Information regarding the running style to increase efficiency and/or selection of the correct running equipment, such as shoe type, can minimize the risk of injury, e.g., matching a runner's gait to a particular set of cushioning technologies found in modern shoes (neutral/support cushioning). Awareness of training or selection of the correct equipment requires an understanding of a runner's biomechanics, such as determining foot orientation when it strikes the ground. Previous work involved a low-cost approach with a foot-mounted inertial measurement unit (IMU) and an associated zero-crossing-based methodology to objectively understand a runner's biomechanics (in any setting) to learn about shoe selection. Here, an investigation of the previously presented ZC-based methodology is presented only to determine general validity for running gait assessment in a range of running abilities from novice (8 km/h) to experienced (16 km/h+). In comparison to Vicon 3D motion tracking data, the presented approach can extract pronation, foot strike location, and ground contact time with good [ICC(2,1) > 0.750] to excellent [ICC(2,1) > 0.900] agreement between 8–12 km/h runs. However, at higher speeds (14 km/h+), the ZC-based approach begins to deteriorate in performance, suggesting that other features and approaches may be more suitable for faster running and sprinting tasks.

7 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
FYFraser Young
Fraser Young
RMRachel Mason
Rachel Mason
RMRosie Morris
Rosie Morris
SSSamuel Stuart
Samuel Stuart
Alan GodfreyAlan Godfrey
Alan Godfrey
Running gait assessment is essential for the development of technical optimization strategies as well as to inform injury prevention and rehabilitation. Currently, running gait assessment relies on (i) visual assessment, exhibiting subjectivity and limited reliability, or (ii) use of instrumented approaches, which often carry high costs and can be intrusive due to the attachment of equipment to the body. Here, the use of an IoT-enabled markerless computer vision smartphone application based upon Google’s pose estimation model BlazePose was evaluated for running gait assessment for use in low-resource settings. That human pose estimation architecture was used to extract contact time, swing time, step time, knee flexion angle, and foot strike location from a large cohort of runners. The gold-standard Vicon 3D motion capture system was used as a reference. The proposed approach performs robustly, demonstrating good (ICC(2,1) > 0.75) to excellent (ICC(2,1) > 0.90) agreement in all running gait outcomes. Additionally, temporal outcomes exhibit low mean error (0.01–0.014 s) in left foot outcomes. However, there are some discrepancies in right foot outcomes, due to occlusion. This study demonstrates that the proposed low-cost and markerless system provides accurate running gait assessment outcomes. The approach may help routine running gait assessment in low-resource environments.

27 September 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CWConor Wall
Conor Wall
DPDylan Powell
Dylan Powell
FYFraser Young
Fraser Young
AZAaron J. Zynda
Aaron J. Zynda
SSSam Stuart
Sam Stuart
Alan GodfreyAlan Godfrey
Alan Godfrey
Mild traumatic brain injury (mTBI or concussion) is receiving increased attention due to the incidence in contact sports and limitations with subjective (pen and paper) diagnostic approaches. If an mTBI is undiagnosed and the athlete prematurely returns to play, it can result in serious short-term and/or long-term health complications. This demonstrates the importance of providing more reliable mTBI diagnostic tools to mitigate misdiagnosis. Accordingly, there is a need to develop reliable and efficient objective approaches with computationally robust diagnostic methods. Here in this pilot study, we propose the extraction of Mel Frequency Cepstral Coefficient (MFCC) features from audio recordings of speech that were collected from athletes engaging in rugby union who were diagnosed with an mTBI or not. These features were trained on our novel particle swarm optimised (PSO) bidirectional long short-term memory attention (Bi-LSTM-A) deep learning model. Little-to-no overfitting occurred during the training process, indicating strong reliability of the approach regarding the current test dataset classification results and future test data. Sensitivity and specificity to distinguish those with an mTBI were 94.7% and 86.2%, respectively, with an AUROC score of 0.904. This indicates a strong potential for the deep learning approach, with future improvements in classification results relying on more participant data and further innovations to the Bi-LSTM-A model to fully establish this approach as a pragmatic mTBI diagnostic tool.

11 July 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
FYFraser Young
Fraser Young
SSSamuel Stuart
Samuel Stuart
RMRobert McNicol
Robert McNicol
RMRosie Morris
Rosie Morris
CDCraig Downs
Craig Downs
Alan GodfreyAlan Godfrey
Alan Godfrey
Running gait assessment and running shoe recommendation is important for the injury prevention of runners who exhibit different skill-levels and running styles. Traditionally, running gait assessment for shoe recommendation relies upon a combination of trained professionals (e.g., sports-therapists, physiotherapists) and complex equipment such as motion or pressure sensors, often incurring a high-cost to the consumer. Despite this, assessments are still prone to subjectivity, and may differ between assessors. Alternatively, methods to provide low-cost, reproduceable gait assessment has become a necessity, especially within a habitual (low-resource) context, with many traditional methods generally unavailable due to the need of professional assistance and more recently the COVID-19 pandemic. Fuzzy logic has shown to be an effective tool in the assessment and identification of gait by providing the potential for a high-accuracy methodology, while retaining a low computational cost; ideal for applications within embedded systems. Here, we present a novel shoe recommendation fuzzy inference system from the classification of two key running gait parameters, foot strike and pronation from a single foot mounted internet of thing (IoT) enabled wearable inertial measurement unit. The fuzzy approach provides excellent (ICC > 0.9) accuracy, while significantly increasing the resolution of the gait assessment technique, providing a more detailed running gait analysis.