With the proposed goal of “Carbon Neutrality”, photovoltaic energy is gradually gaining the leading role in energy transformation. At present, crystalline silicon cells are still the mainstream technology in the photovoltaic industry, but due to the similarity of defect characteristics and the small scale of the defects, automatic defect detection of photovoltaic cells (PV) by electroluminescence (EL) imaging is a challenging task. In order to better meet the growing demand for high-quality photovoltaic cell products in intelligent manufacturing and use, and ensure the safe and efficient operation of photovoltaic power stations, this paper proposes an improved abnormal detection method based on Faster R-CNN for the surface defect EL imaging of photovoltaic cells, which integrates a lightweight channel and spatial convolution attention module. It can analyze the crack defects in complex scenes more efficiently. The clustering algorithm was used to obtain a more targeted anchor frame for photovoltaic cells, which made the model converge faster and enhanced the detection ability. The normalized distance between the prediction box and the target box is minimized by considering the DIoU loss function for the overlapping area of the boundary box and the distance between the center points. The experiment shows that the average accuracy of surface defect detection for EL images of photovoltaic cells is improved by 14.87% compared with the original algorithm, which significantly improves the accuracy of defect detection. The model can better detect small target defects, meet the requirements of surface defect detection of photovoltaic cells, and proves that it has good application prospects in the field of photovoltaic cell defect detection.
Image-to-image steganography refers to the practice of hiding secret image within a cover image, serving as a crucial technique for secure communication and data protection. Existing image-to-image generative adversarial network-based steganographic methods for image hiding demonstrate a high embedding capacity. However, there is still significant room for improvement in terms of the quality of the stego images and the extracted secret images. In this study, we propose an architecture for inconspicuously hiding an image within the Y channel of another image, leveraging a U-Net network and a multi-scale fusion ExtractionBlock. The network is jointly trained using a loss function combining Perceptual Path Length (PPL) and Mean Square Error (MSE). The proposed network is trained and tested on two datasets, Labeled Faces in the Wild and Pascal visual object classes. Experimental results demonstrate that the model not only achieves high invisibility and significant hiding capacity (8 bits per pixel) without altering the color information of the cover image but also exhibits strong generalization ability. Additionally, we introduce the Modified Multi-Image Similarity Metric (MMISM), which integrates the Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index Metric (SSIM) values of images, to comprehensively evaluate the network’s hiding and extraction capabilities.
Green and low-carbon has become the main theme of global energy development. Data centers are the core of the digital age, carrying huge arithmetic demand. Data centers must implement green low-carbon energy efficiency management to improve energy efficiency, reduce energy waste and carbon emissions, and achieve sustainable development. As a result, an intelligent management strategy for dynamic energy efficiency of data center networks with Artificial Intelligence (AI) fitting control is proposed. Firstly, a Long Short-Term Memory (LSTM) network is used for long sequence trend prediction to predict the temperature of the data center in the next sequence using the temperature of the past 15 sequences and the power consumption of the equipment as parameters. Then, based on the prediction results, the intelligent air conditioning controller based on Deep Q-Network (DQN) is designed to update the parameters by using the gradient of double-Q network and error backpropagation, and the optimal control action is selected by using the ε-greedy strategy to ensure that the prediction of the hotspot does not occur. Experiments show that the average absolute errors of temperature prediction for supply air, return air, cold aisle as well as hot aisle are 0.32 °C, 0.21 °C, 0.36 °C and 0.19 °C, respectively. The Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) decreased by an average of 2.6% and 2.5%, respectively. The method achieves the purpose of predicting future temperatures and intelligently controlling the output so that the data center can satisfy the premise of normal operation and thus achieve more efficient energy use.
20 April 2024 in Peer-to-Peer Networking and Applications