Majo Carrasco-Tenezaca

Dr. Majo Carrasco-Tenezaca

CISeAL - FADA, Pontificia Universidad Católica del Ecuador, Quito, Pichincha, Ecuador
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2020 in Philosophical Transactions of the Royal Society B: Biological Sciences
Verified
Journal Article
Open access
SLSteven W. Lindsay
Steven W. Lindsay
MDMichael Davies
Michael Davies
GAGraham Alabaster
Graham Alabaster
HAHector Altamirano
Hector Altamirano
EJEbrima Jatta
Ebrima Jatta
JKJakob Knudsen
Jakob Knudsen
In sub-Saharan Africa, most transmission of mosquito-transmitted diseases, such as malaria or dengue, occurs within or around houses. Preventing mosquito house entry and reducing mosquito production around the home would help reduce the transmission of these diseases. Based on recent research, we make key recommendations for reducing the threat of mosquito-transmitted diseases through changes to the built environment. The mnemonic, DELIVER , recommends the following best practices: (i) D oors should be screened, self-closing and without surrounding gaps; (ii) E aves, the space between the wall and roof, should be closed or screened; (iii) houses should be L ifted above the ground; (iv) I nsecticide-treated nets should be used when sleeping in houses at night; (v) houses should be V entilated, with at least two large-screened windows to facilitate airflow; (vi) E nvironmental management should be conducted regularly inside and around the home; and (vii) R oofs should be solid, rather than thatch. DELIVER is a package of interventions to be used in combination for maximum impact. Simple changes to the built environment will reduce exposure to mosquito-transmitted diseases and help keep regions free from these diseases after elimination. This article is part of the theme issue ‘Novel control strategies for mosquito-borne diseases'.

1 May 2021 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
EJEbrima Jatta
Ebrima Jatta
Majo Carrasco-TenezacaMajo Carrasco-Tenezaca
Majo Carrasco-Tenezaca
MJMusa Jawara
Musa Jawara
JBJohn Bradley
John Bradley
SCSainey Ceesay
Sainey Ceesay
SLSteve W. Lindsay
Steve W. Lindsay
In sub-Saharan Africa, cooler houses would increase the coverage of insecticide-treated bednets, the primary malaria control tool. We examined whether improved ventilation, using windows screened with netting, cools houses at night and reduces malaria mosquito house entry in The Gambia. Identical houses were constructed, with badly fitting doors the only mosquito entry points. Two men slept in each house and mosquitoes captured using light traps. First, temperature and mosquito density were compared in four houses with 0, 1, 2 and 3 screened windows. Second, carbon dioxide (CO2), a major mosquito attractant, was measured in houses with (i) no windows, (ii) screened windows and (iii) screened windows and screened doors. Computational fluid dynamic modelling captured the spatial movement of CO2. Increasing ventilation made houses cooler, more comfortable and reduced malaria mosquito house entry; with three windows reducing mosquito densities by 95% (95%CI = 90–98%). Screened windows and doors reduced the indoor temperature by 0.6°C (95%CI = 0.5–0.7°C), indoor CO2 concentrations by 31% between 21.00 and 00.00 h and malaria mosquito entry by 76% (95%CI = 69–82%). Modelling shows screening reduces CO2 plumes from houses. Under our experimental conditions, cross-ventilation not only reduced indoor temperature, but reduced the density of house-entering malaria mosquitoes, by weakening CO2 plumes emanating from houses.

22 April 2022 in International Journal for Equity in Health
Verified
Journal Article
Open access
PDF file
ABAnthony Brusnahan
Anthony Brusnahan
Majo Carrasco-TenezacaMajo Carrasco-Tenezaca
Majo Carrasco-Tenezaca
BBBenjamin R. Bates
Benjamin R. Bates
RRRosellen Roche
Rosellen Roche
MGMario Grijalva
Mario Grijalva
Background: Access to professional health care providers in Loja Province, Ecuador can be difficult for many citizens. The Health Care Access Barrier Model (HCAB) was established to provide a framework for classification, analysis, and reporting of modifiable health care access barriers. This study uses the HCAB Model to identify barriers and themes impacting access to health care access in southern rural Ecuador. Methods: The research team interviewed 22 participants and completed 15 participant observation studies in the study area. Interviews and a single focus group session of artisans were recorded and transcribed from Spanish to English, and thematic analysis was performed. Results: The thematic analysis found financial, structural, and cognitive health care access barriers. Cost of medications, transportation, missed responsibilities at work and home, difficulty scheduling appointments, and misconceptions in health literacy were the predominant themes contributing to health care access. These pressure points provide insight on where actions may be taken to alleviate access barriers. Conclusion: Modifiable health care access barriers outlined in the HCAB are evident in the study area. Further research and implementation of programs to resolve these barriers, such as the creation of health care subcenters and/or mobile clinic, insurance coverage of specialized care, increasing availability and accessibility to affordable transportation, improving roadways, introduction of a 24/7 call center to schedule medical visits, monetary incentive for primary care physicians to practice in rural and underserved areas, provision of affordable work equipment, and emphasizing the improvement of health care literacy through education, may diminish current barriers, identify additional barriers, and improve overall health in the rural area of Loja, Ecuador and similar rural regions around the world.

29 October 2021 in Malaria Journal
Verified
Journal Article
Open access
PDF file
Majo Carrasco-TenezacaMajo Carrasco-Tenezaca
Majo Carrasco-Tenezaca
EJEbrima Jatta
Ebrima Jatta
MJMusa Jawara
Musa Jawara
JBJohn Bradley
John Bradley
MPMargaret Pinder
Margaret Pinder
SLSteve W. Lindsay
Steve W. Lindsay
Background: In rural sub-Saharan Africa, thatch roofs are being replaced by metal roofs. Metal roofing, however, increases indoor temperatures above human comfort levels, and thus makes it more likely that residents will not use an insecticide-treated bed net (ITN) at night. Whether the colour of a metal roof affects indoor temperature and human comfort was assessed. Methods: Two identical, experimental houses were constructed with metal roofs in rural Gambia. Roof types were: (1) original bare-metal, (2) painted with red oxide primer or (3) white gloss, to reflect solar radiation. Pairwise comparisons were run in six, five-night blocks during the malaria season 2018. Indoor climate was measured in each house and multivariate analysis used to compare indoor temperatures during the day and night. Results: From 21.00 to 23.59 h, when most residents decide whether to use an ITN or not, the indoor temperature of a house with a bare metal roof was 31.5 °C (95% CI 31.2–31.8 °C), a red roof, 30.3 °C (95% CI 30.0–30.6) and a white roof, 29.8 °C (95% CI 29.4–30.1). During the same period, red-roofed houses were 1.23 °C cooler (95% CI 1.22–1.23) and white roofs 1.74 °C cooler (95% CI 1.70–1.79) than bare-metal roofed houses (p < 0.001). Similar results were found from 00.00 to 06.00 h. Maximum daily temperatures were 0.93 °C lower in a white-roofed house (95% CI 0.10–0.30, p < 0.001), but not a red roof (mean maximum temperature difference = 0.44 °C warmer, 95% CI 0.43–0.45, p = 0.081), compared with the bare-metal roofed houses. Human comfort analysis showed that from 21.00 to 23.59 h houses with white roofs (comfortable for 87% time) were more comfortable than bare-metal roofed houses (comfortable for 13% time; odds ratio = 43.7, 95% CI 27.5–69.5, p < 0.001). The cost of painting a metal roof white is approximately 31–68 USD. Conclusions: Houses with a white roof were consistently cooler and more comfortable than those with a bare metal roof. Painting the roofs of houses white is a cheap way of making a dwelling more comfortable for the occupants and could potentially increase bed net use in hot humid countries.

1 May 2021 in Journal of The Royal Society Interface
Verified
Journal Article
Open access
Majo Carrasco-TenezacaMajo Carrasco-Tenezaca
Majo Carrasco-Tenezaca
MJMusa Jawara
Musa Jawara
MAMahamed Y. Abdi
Mahamed Y. Abdi
JBJohn Bradley
John Bradley
OBOtis Sloan Brittain
Otis Sloan Brittain
SLSteve W. Lindsay
Steve W. Lindsay
Most malaria infections in sub-Saharan Africa are acquired indoors, thus finding effective ways of preventing mosquito house entry should reduce transmission. Since most malaria mosquitoes fly less than 1 m from the ground, we tested whether raising buildings off the ground would prevent the entry of Anopheles gambiae, the principal African malaria vector, in rural Gambia. Nightly collections of mosquitoes were made using light traps from four inhabited experimental huts, each of which could be moved up or down. Mosquito house entry declined with increasing height, with a hut at 3 m reducing An. gambiae house entry by 84% when compared with huts on the ground. A propensity for malaria vectors to fly close to the ground and reduced levels of carbon dioxide, a major mosquito attractant, in elevated huts, may explain our findings. Raised buildings may help reduce malaria transmission in Africa.

23 February 2022 in Malaria Journal
Verified
Journal Article
Open access
PDF file
FSFiona C. Shenton
Fiona C. Shenton
MJMusa Jawara
Musa Jawara
Majo Carrasco-TenezacaMajo Carrasco-Tenezaca
Majo Carrasco-Tenezaca
JKJakob Knudsen
Jakob Knudsen
UDUmberto D’aLessandro
Umberto D’aLessandro
SLSteve W. Lindsay
Steve W. Lindsay
Background: The World Health Organization recommends house screening as a tool for malaria control, yet evidence of the long-term durability, functionality and acceptability of this intervention is lacking. In this study, the sustainability and use of novel types of screened doors and windows was examined 4 years after installation in a Gambian village. Methods: A survey of 31 houses, each with two screened doors and two screened windows, was conducted in the rainy season. There were four types of screened door and two types of screened window. Trained staff carried out the survey and interviews of room owners were conducted in the local language before translation into English. Results: Structurally, the manufactured doors and windows were highly durable and in excellent condition. Most doors shut smoothly 50/61 (82%), although only 25/61 (41%) shut fully automatically with the latch slotting into the hole on the frame and holding fast. Door locks were less robust, with only (24/61) 39% present and working. Blinds proved especially flimsy, with only 4/109 (4%) of door blinds and 10/56 (18%) of window blinds present and in working order. Householders hung curtains inside most doors 50/61 (82%) and in 26/61 (43%) of the windows. Front doors were commonly found propped open 21/31 (68%) and 23/27 (85%) of those with a front door curtain, put their curtains down at night. Doors and windows were well liked, 19/31 (61%) of respondents were happy with them because they kept mosquitoes out 14/31 (45%) and provided security 12/31 (39%). The main reason given for the use of curtains was to provide privacy 26/28 (93% of those with curtains), especially while the door was open or had ‘see-through’ panels. Conclusions: Overall, the screened doors and windows were in full-working order and undamaged after 4 years of use. The doors and windows were well liked, especially for their ability to reduce the entry of mosquitoes and for the security they afforded. Improvements to the lock design are needed before scale-up. Most householders hung curtains behind their doors for privacy. Installation of screening in buildings should be accompanied with recommendations that at night, when doors and windows are closed, curtains be lifted or drawn to one side—to improve ventilation and keep the house cool.