Polyurethane-based materials, which are widely used in exterior cladding, pose a great risk for buildings because they can easily catch fire at temperatures as low as 50–65 °C. Thus, different materials are needed to ensure that structures exposed to high temperatures do not have any stability problems. In this study, expanded perlite aggregate plaster (EPAP) was produced to eliminate the negative effects that may occur in buildings exposed to high temperatures. High temperature tests were carried out on test plates of different thicknesses to determine the effect of plaster thickness under high temperatures. In order to compare the effects of high temperatures, a test sample of normal aggregate plaster (NAP), which is widely used in buildings, was prepared. In the high temperature test, the temperature values on the back surfaces of the EPAP (≈115 °C) test plates were approximately 3 times lower than the temperature values of the NAP (≈350 °C) test plate. It can be said that structural stability loss and durability problems may occur in structures covered with NAP in a high-temperature environment, and that no negative effect will occur in terms of structural stability and durability problems in structures covered with EPAP in high temperature environments.
4 August 2026 in Uludağ University Journal of The Faculty of Engineering
A study was carried out on the production of structural lightweight concrete using raw perlite aggregate with a maximum aggregate particle diameter of 12.5 mm and granulometry conforming to the Fuller equation. For this, Concrete samples with five different cement dosages such as 150, 200, 250, 300 and 350 kg/m3 and two different slump values were prepared, to regulate the workability of fresh concrete, 1% of cement weight plasticizer was added to all mixes. The physical and mechanical properties of fresh and hardened concrete were determined according to the relevant standards of ASTM. According to the research results, it has been seen that it is possible to produce structural lightweight concrete with a unit weight of between 1600 and 1900 kg/m3 using perlite aggregate. The highest compressive strength of 35 MPa was reached after 90 days with a binder amount of 350 kg/m3 . According to the results of the research, one of the most effective parameters on the mechanical and physical properties of concrete is the slump value and the other is the amount of binder. The split tensile strength of the produced concrete was 11% of the compressive strength and the water absorption rate was 8%.
The main causes of damage include poor site selection, such as building on fault lines or on fill soil, as well as deficiencies in design, materials, and workmanship. Damage levels are also linked to the economic conditions of the region. In the 1939 earthquake, there were high casualties due to the magnitude of the earthquake, lack of engineering design in traditional structures and unsuitable soil conditions. Similarly, in the 1992 earthquake, unexpected damage occurred due to faulty designs created by inexperienced engineers who lacked sufficient knowledge of the seismic behavior of structures, errors in craftsmanship and workmanship, and unsuitable residential area selection for construction. These problems continue today and put most of the building stock at risk in case of a major earthquake. Seismic steel isolators are used in two new buildings in the city; if they are effective, they should be made mandatory in new construction. Otherwise, consideration should be given to relocating the city to the more stable southern rocky areas, which were unaffected in both 1939 and 1992.
This study investigates the feasibility of producing high-strength lightweight concrete using regional volcanic aggregate (RVA) and examines the performance of the produced concrete. Various mix designs conforming to ASTM and TS EN standards were applied to achieve the targeted strength and density. The study also investigated the effect of water/cement ratio (W/C) and cement content on the mechanical and physical properties of high-strength lightweight concrete. Experimental tests such as compressive strength, tensile strength, density, water absorption, and elastic modulus were conducted to determine the effect of cement content and lightweight aggregate on the overall behavior of the concrete. To ensure adequate workability, superplasticizer was added to all mixes at a rate of 1.5% of the cement weight. The slump values of fresh concrete met modern requirements for good workability, pumpability, and high strength. The results showed that, provided a superplasticizer is used, high-strength concrete with a density range of 1830 to 1915 kg/m³ can be produced using 450 kg/m³ of cement. The results show that the porous structure and pozzolanic properties of RVA significantly increase the mechanical strength of concrete and, thanks to its porous structure, reduce its unit weight by 20–25%. The highest compressive strength recorded within 90 days for a mixture containing 650 kg/m³ of cement was 87 MPa. It was concluded that the W/C ratio and cement content have a significant effect on the mechanical and physical properties of these concretes.
Reliable estimation of the in situ compressive strength of concrete is an essential component of the assessment of existing reinforced concrete structures, particularly in earthquake-prone regions. This study investigates the regional calibration and applicability of relationships based on the Schmidt rebound hammer, ultrasonic pulse velocity, and core tests for concrete used in the Erzincan region of Türkiye. Field investigations were carried out in reinforced concrete buildings constructed before and after the regulatory requirement to use ready-mixed concrete; the former were generally built with traditionally produced site-mixed concrete and the latter with ready-mixed concrete. Laboratory specimens produced from locally used ready-mixed concrete and core samples obtained from existing buildings were investigated. Linear regression models relating the rebound number and the ultrasonic pulse velocity to compressive strength were developed, and a combined rebound–ultrasonic (SonReb) model was also established. Model performance was evaluated using goodness-of-fit and error metrics, predictive performance was assessed by repeated k-fold cross-validation, and the relationships were independently validated against core samples from additional buildings. The rebound-based models showed strong relationships with compressive strength for laboratory specimens and for cores from both ready-mixed and traditionally produced concrete, and the combined SonReb model predicted strength more accurately than either single-parameter model. In the independent validation, the rebound-based relationships produced deviations from core strength that are acceptable in view of the material safety factor for ready-mixed concrete, but considerably larger deviations for traditionally produced concrete, while the ultrasonic-only relationship was too imprecise to be used on its own. These results indicate that locally calibrated non-destructive relationships can provide useful estimates of in situ concrete strength when applied to concrete with characteristics comparable to those represented in the calibration dataset. However, the proposed relationships should not be transferred directly to other regions or to substantially different materials and construction practices without additional calibration and validation. The principal contribution of this study is the regional calibration and validation of non-destructive concrete strength relationships and the quantitative evaluation of the combined rebound–ultrasonic approach for ready-mixed concrete in the Erzincan region.