Summary: Objective: To evaluate the effectiveness of circular external skeletal fixation (CESF) in treating fractures of the distal radius and ulna in toy breed dogs, and to document the type and frequency of complications associated with this technique.Methods: The medical records of small breed dogs with fractures of the distal radius and ulna admitted to the University of Turin and to the Clinica Ferretti between 2002 and 2009 were retrospectively reviewed. The criteria for inclusion of cases in the study were: body weight of 5 kg or less, transverse or short oblique fracture of the distal third of the radius and ulna, no previous repair attempts, and treatment with CESF as the sole method of fixation.Results: Twenty fractures in 16 dogs satisfied the criteria for inclusion into this study. No signs of infection or failure of fixation were detected in any case. Mean frontal plane alignment was 4.7° ± 2.7° and mean sagittal plane alignment was 12.7° ± 7.2°. Postoperative complications occurred in one patient. All fractures achieved union. Mean time until radiographic evidence of a bridging callus and subsequent implant removal was 71 days (range: 30–120).Conclusions: The results of this study support the use of CESF for treatment of fractures of the distal radius and ulna in toy breed dogs as an alternative to other methods of fracture fixation. However, this technique requires a series of follow-up examinations to evaluate the stability of the apparatus, the soundness of the wires and to determine the appropriate time for implant removal.
21 January 2020 in Journal of Materials Science: Materials in Medicine
Summary: Objectives: To quantify the effect of antebrachial torsion on the miscalculation of radial valgus measured radiographically and to assess a radiographic positioning method used to mitigate torsion-associated artifactual miscalculation of concurrent frontal plane angulation.Methods: A canine cadaveric forelimb was used to model different combinations of valgus and external torsion. Valgus was induced in the limb in increments of five degrees, radiographic images were taken at each increment, and the observed radiographic valgus was measured. Various angles of torsion were then induced and the process was repeated for a range of torsional angles at 15° increments. For the second objective, the study was repeated with the forelimb rotationally re-positioned to mirror the degree of the induced torsion of the deformity at each valgus and torsion iteration.Results: Both zero degrees and 15° torsional iterations possessed mean artifactual valgus (AV) values between zero and five degrees for every valgus increment. With torsion of 30° and higher, mean AV values varied widely and did not fall within the zero to five degree accepted range. Rotationally re-positioning the limb in an attempt to alleviate the AV discrepancies resulted in the 30° torsional group having acceptable AV values for valgus values between zero and 20°.Clinical significance: Increasing antebrachial torsion interferes with accurate radiographic measurement of frontal plane deformities. Radiographically repositioning the limb allows the accurate calculation of more valgus and torsion combinations, but still results in miscalculations of more complex deformities.
1 September 2012 in Veterinary Clinics of North America: Small Animal Practice