Introduction: It is well known that etomidate may cause adrenal insufficiency. However, the clinical relevance of adrenal suppression after a single dose of etomidate remains vague. The aim of this study was to investigate the association between the administration of a single dose of etomidate or an alternative induction regime ahead of major cardiac surgery and clinical outcome parameters associated with adrenal suppression and onset of sepsis. Methods: The anesthesia and intensive care unit (ICU) records from patients undergoing cardiac surgery over five consecutive years (2008 to 2012) were retrospectively analyzed. The focus of the analysis was on clinical parameters like mortality, ventilation hours, renal failure, and sepsis-linked serum parameters. Multivariate analysis and Cox regression were applied to derive the results. Results: In total, 3,054 patient records were analyzed. A group of 1,775 (58%) patients received a single dose of etomidate; 1,279 (42%) patients did not receive etomidate at any time. There was no difference in distribution of age, American Society of Anesthesiologists physical score, duration of surgery, and Acute Physiology and Chronic Health Evaluation II score. Postoperative data showed no significant differences between the two groups in regard to mortality (6.8% versus 6.4%), mean of mechanical ventilation hours (21.2 versus 19.7), days in the ICU (2.6 versus 2.5), hospital days (18.7 versus 17.4), sepsis-associated parameters, Sequential Organ Failure Assessment score, and incidence of renal failure. Administration of etomidate showed no significant influence (P = 0.6) on hospital mortality in the multivariate Cox analysis. Conclusions: This study found no evidence for differences in key clinical outcome parameters based on anesthesia induction with or without administration of a single dose of etomidate. In consequence, etomidate might remain an acceptable option for single-dose anesthesia induction.
4 March 2017 in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Prehospital intravenous access provides the opportunity to sample blood from an emergency patient at the earliest possible moment in the course of acute illness and in a state prior to therapeutic interventions. Our study investigates the pre-analytical stability of biomarkers in prehospital emergency medicine and will answer the question whether an approach of blood sampling out in the field will deliver valid laboratory results. We prepared pairs of blood samples from healthy volunteers and volunteering patients post cardio-thoracic surgery. While one sample set was analysed immediately, the other one was subjected to a worse-than-reality treatment of 60 min time-lapse and standardized mechanical forces outside of the hospital through actual ambulance transport. We investigated 21 parameters comprising blood cells, coagulation tests, electrolytes, markers of haemolysis and markers of cardiac ischemia. Bland-Altman analysis was used to investigate differences between test groups. Differences between test groups were set against the official margins of test accuracy as given by the German Requirements for Quality Assurance of Medical Laboratory Examinations. Agreement between immediate analysis and our prehospital treatment is high as demonstrated by Bland-Altman plotting. Mechanical stress and time delay do not produce a systematic bias but only random inaccuracy. The limits of agreement for the tested parameters are generally within clinically acceptable ranges of variation and within the official margins as set by the German Requirements for Quality Assurance of Medical Laboratory Examinations. We subjected blood samples to a standardized treatment marking a worse-than-reality scenario of prehospital time delay and transport. Biomarkers including indicators of myocardial ischemia showed high pre-analytical stability. We conclude the validity of blood samples from a prehospital environment.
Background: After sternotomy, the spectrum for sternal osteosynthesis comprises standard wiring and more complex techniques, like titanium plating. The aim of this study is to develop a predictive risk score that evaluates the risk of sternum instability individually. The surgeon may then choose an appropriate sternal osteosynthesis technique that is risk- adjusted as well as cost-effective. Methods: Data from 7.173 patients operated via sternotomy for all cardiovascular indications from 2008 until 2017 were retrospectively analyzed. Sternal dehiscence occurred in 2.5% of patients (n = 176). A multivariable analysis model examined pre- and intraoperative factors. A multivariable logistic regression model and a backward elimination based on the Akaike Information Criterion (AIC) a logistic model were selected. Results: The model showed good sensitivity and specificity (area under the receiver-operating characteristic curve, AUC: 0.76) and several predictors of sternal instability could be evaluated. Multivariable logistic regression showed the highest Odds Ratios (OR) for reexploration (OR 6.6, confidence interval, CI [4.5–9.5], p < 0.001), obesity (body mass index, BMI > 35 kg/m2) (OR 4.23, [CI 2.4–7.3], p < 0.001), insulin-dependent diabetes mellitus (IDDM) (OR 2.2, CI [1.5–3.2], p = 0.01), smoking (OR 2.03, [CI 1.3–3.08], p = 0.001). After weighting the probability of sternum dehiscence with each factor, a risk score model was proposed scaling from − 1 to 5 points. This resulted in a risk score ranging up to 18 points, with an estimated risk for sternum complication up to 74%. Conclusions: A weighted scoring system based on individual risk factors was specifically created to predict sternal dehiscence. High-scoring patients should receive additive closure techniques.
High-speed camera examination of heart valves is an established technique to examine heart valve prosthesis. The aim of this study was to examine the possibility to transmit new tools for high-speed camera examination of heart valve behavior under near-physiological conditions in a porcine ex vivo beating heart model. After explantation of the piglet heart, main coronary arteries were cannulated and the heart was reperfused with the previously collected donor blood. When the heart started beating in sinus rhythm again, the motion of the aortic and mitral valve was recorded using a digital high-speed camera system (recording rate 2,000 frames/sec). The image sequences of the mitral valve were analyzed, and digital kymograms were calculated at different angles for the exact analysis of the different closure phases. The image sequence of the aortic valve was analyzed, and several snakes were performed to analyze the effective orifice area over the time. Both processing tools were successfully applied to examine heart valves in this ex vivo beating heart model. We were able to investigate the exact open and closure time of the mitral valve, as well as the projected effective orifice area of the aortic valve over the time. The high-speed camera investigation in an ex vivo beating heart model of heart valve behavior is feasible and also reasonable because of using processing feature such as kymography for exact analysis. These analytical techniques might help to optimize reconstructive surgery of the mitral valve and the development of heart valve prostheses in future.
Introduction: Starting a minimally invasive cardiac surgery (MICS) for mitral valve repair (MVR) program is challenging as it requires a new learning curve, but compromising surgical results at the same time is not acceptable. Here, we describe our surgical educational experience of starting a new MICS program at a university heart center in Germany. Methods: A dedicated team for the new MICS program including 2 cardiac surgeons, 1 cardiac anesthetist, 1 perfusionist, and 1 scrub nurse was chosen. The use of long shafted instruments was trained in a low-cost self-assembled MICS simulator, and the EACTS endoscopic dry lab course was visited. Thereafter, 1 MICS center was visited for direct observation and peer-to-peer education for 6 weeks. The mentor observed the first 10 cases performed by the mentee. The surgical mitral valve expertise of 1 single cardiac surgeon was retrospectively analyzed between April 2016 and April 2021. Results: Before the implementation of the MICS-MVR program, 18 mitral valve operations have been performed through sternotomy between April 2016 and October 2018 including 12 replacements and 6 ring annuloplasties. After starting the MICS-MVR program, 73 mitral operations have been performed by the same surgeon of which 53 video-assisted through minithoracotomy (72.6%). 83.1% of the MICS procedures included complex repair (n = 38) and ring annuloplasty (n = 6). Open heart MV surgery was necessary in 20 patients due to concomitant procedures (n = 8), redo procedures (n = 2), severe endocarditis (n = 4), or contraindication for MICS such as PAD (n = 6). There have been no deaths, 1 stroke, and 1 cardiac vascular (RCX) complication. Two patients required conversion to sternotomy and one pericardiocentesis in the long term. Conclusion: Typically, excellent exposure and high repair rates of the MV has led us offer MICS approach to a majority of patients with isolated MV disease. Careful planning and a strict mentor-mentee concept facilitated a safe startup of an MICS program in a busy university heart center.
24 August 2022 in The Thoracic and Cardiovascular Surgeon Reports
An 83-year-old woman presented with a new onset of dyspnea and dysphonia. Physical examination revealed no abnormalities. Computerized tomography, bidimensional echocardiography, and cardiac magnetic resonance confirmed the presence of a cardiac mass in the left atrium. Surgical resection was uneventful and showed the origin of the mass in the ostium of the left inferior pulmonary vein. Histological evaluation revealed undifferentiated pleomorphic sarcoma with myxoid features. This case highlights the importance of considering cardiac neoplasms as a rare differential diagnosis, including rare and misleading clinical presentations.