Nizam Ahamed

Dr. Nizam Ahamed

Neuromuscular Research Laboratory, Department of Sports Medicine and Nutrition, University of Pittsburgh, Pittsburgh, PA 15203, USA
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
RPRajkumar Palaniappan
Rajkumar Palaniappan
KSKenneth Sundaraj
Kenneth Sundaraj
NANizam Ahamed
Nizam Ahamed

11 March 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MIMd. Anamul Islam
Md. Anamul Islam
KSKenneth Sundaraj
Kenneth Sundaraj
RAR Badlishah Ahmad
R Badlishah Ahmad
NANizam Ahamed
Nizam Ahamed
Mechanomyography (MMG) has been extensively applied in clinical and experimental practice to examine muscle characteristics including muscle function (MF), prosthesis and/or switch control, signal processing, physiological exercise, and medical rehabilitation. Despite several existing MMG studies of MF, there has not yet been a review of these. This study aimed to determine the current status on the use of MMG in measuring the conditions of MFs. Five electronic databases were extensively searched for potentially eligible studies published between 2003 and 2012. Two authors independently assessed selected articles using an MS-Word based form created for this review. Several domains (name of muscle, study type, sensor type, subject's types, muscle contraction, measured parameters, frequency range, hardware and software, signal processing and statistical analysis, results, applications, authors' conclusions and recommendations for future work) were extracted for further analysis. From a total of 2184 citations 119 were selected for full-text evaluation and 36 studies of MFs were identified. The systematic results find sufficient evidence that MMG may be used for assessing muscle fatigue, strength, and balance. This review also provides reason to believe that MMG may be used to examine muscle actions during movements and for monitoring muscle activities under various types of exercise paradigms. Overall judging from the increasing number of articles in recent years, this review reports sufficient evidence that MMG is increasingly being used in different aspects of MF. Thus, MMG may be applied as a useful tool to examine diverse conditions of muscle activity. However, the existing studies which examined MMG for MFs were confined to a small sample size of healthy population. Therefore, future work is needed to investigate MMG, in examining MFs between a sufficient number of healthy subjects and neuromuscular patients.

29 March 2013 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MIMd. Anamul Islam
Md. Anamul Islam
KSKenneth Sundaraj
Kenneth Sundaraj
RAR. Badlishah Ahmad
R. Badlishah Ahmad
NANizam Ahamed
Nizam Ahamed
AAAsraf Ali
Asraf Ali
Mechanomyography (MMG) is extensively used in the research of sensor development, signal processing, characterization of muscle activity, development of prosthesis and/or switch control, diagnosis of neuromuscular disorders, and as a medical rehabilitation tool. Despite much existing MMG research, there has been no systematic review of these. This paper aims to determine the current status of MMG in sensor development, related signal processing, and applications. Six electronic databases were extensively searched for potentially eligible studies published between 2003 and 2012. From a total of 175 citations, 119 were selected for full-text evaluation and 86 potential studies were identified for further analysis. This systematic review initially reveals that the development of accelerometers for MMG is still in the initial stage. Another important finding of this paper is that sensor placement location on muscles may influence the MMG signal. In addition, we observe that the majority of research processes MMG signals using wavelet transform. Time/frequency domain analysis of MMG signals provides useful information to examine muscle. In addition, we find that MMG may be applied to diagnose muscle conditions, to control prosthesis and/or switch devices, to assess muscle activities during exercises, to study motor unit activity, and to identify the type of muscle fiber. Finally, we find that the majority of the studies use accelerometers as sensors for MMG measurements. We also observe that currently MMG-based rehabilitation is still in a nascent stage. In conclusion, we recommend further improvements of MMG in the areas of sensor development, particularly on accelerometers, and signal processing aspects, as well as increasing future applications of the technique in prosthesis and/or switch control, clinical practices, and rehabilitation.

18 September 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NANizam Ahamed
Nizam Ahamed
DKDylan Kobsar
Dylan Kobsar
LBLauren C Benson
Lauren C Benson
CCChristian Clermont
Christian Clermont
RKRussell Kohrs
Russell Kohrs
RFReed Ferber
Reed Ferber
Running-related overuse injuries can result from a combination of various intrinsic (e.g., gait biomechanics) and extrinsic (e.g., running surface) risk factors. However, it is unknown how changes in environmental weather conditions affect running gait biomechanical patterns since these data cannot be collected in a laboratory setting. Therefore, the purpose of this study was to develop a classification model based on subject-specific changes in biomechanical running patterns across two different environmental weather conditions using data obtained from wearable sensors in real-world environments. Running gait data were recorded during winter and spring sessions, with recorded average air temperatures of -10° C and +6° C, respectively. Classification was performed based on measurements of pelvic drop, ground contact time, braking, vertical oscillation of pelvis, pelvic rotation, and cadence obtained from 66,370 strides (~11,000/runner) from a group of recreational runners. A non-linear and ensemble machine learning algorithm, random forest (RF), was used to classify and compute a heuristic for determining the importance of each variable in the prediction model. To validate the developed subject-specific model, two cross-validation methods (one-against-another and partitioning datasets) were used to obtain experimental mean classification accuracies of 87.18% and 95.42%, respectively, indicating an excellent discriminatory ability of the RF-based model. Additionally, the ranked order of variable importance differed across the individual runners. The results from the RF-based machine-learning algorithm demonstrates that processing gait biomechanical signals from a single wearable sensor can successfully detect changes to an individual’s running patterns based on data obtained in real-world environments.

1 February 2019 in Journal of Biomechanics
Verified
Journal Article
Closed access
NANizam Ahamed
Nizam Ahamed
DKDylan Kobsar
Dylan Kobsar
LBLauren C Benson
Lauren C Benson
CCChristian Clermont
Christian Clermont
SOSean T. Osis
Sean T. Osis
Reed FerberReed Ferber
Reed Ferber

20 August 2012 in Bosnian Journal of Basic Medical Sciences
Verified
Journal Article
Open access
PDF file
AAAsraf Ali
Asraf Ali
KSKenneth Sundaraj
Kenneth Sundaraj
BABadlishah Ahmad
Badlishah Ahmad
NANizam Ahamed
Nizam Ahamed
MIMd. Anamul Islam
Md. Anamul Islam
Even though the amount of rehabilitation guidelines has never been greater, uncertainty continues to arise regarding the efficiency and effectiveness of the rehabilitation of gait disorders. This question has been hindered by the lack of information on accurate measurements of gait disorders. Thus, this article reviews the rehabilitation systems for gait disorder using vision and non-vision sensor technologies, as well as the combination of these. All papers published in the English language between 1990 and June, 2012 that had the phrases “gait disorder” “rehabilitation”, “vision sensor”, or “non vision sensor” in the title, abstract, or keywords were identified from the SpringerLink, ELSEVIER, PubMed, and IEEE databases. Some synonyms of these phrases and the logical words “and” “or” and “not” were also used in the article searching procedure. Out of the 91 published articles found, this review identified 84 articles that described the rehabilitation of gait disorders using different types of sensor technologies. This literature set presented strong evidence for the development of rehabilitation systems using a markerless vision-based sensor technology. We therefore believe that the information contained in this review paper will assist the progress of the development of rehabilitation systems for human gait disorders.