Narutoshi Hibino

Dr. Narutoshi Hibino


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
COChin Siang Ong
Chin Siang Ong
TFTakuma Fukunishi
Takuma Fukunishi
HZHuaitao Zhang
Huaitao Zhang
CHChen Yu Huang
Chen Yu Huang
ANAndrew Nashed
Andrew Nashed
NHNarutoshi Hibino
Narutoshi Hibino
We have developed a novel method to deliver stem cells using 3D bioprinted cardiac patches, free of biomaterials. Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), fibroblasts (FB) and endothelial cells (EC) were aggregated to create mixed cell spheroids. Cardiac patches were created from spheroids (CM:FB:EC = 70:15:15, 70:0:30, 45:40:15) using a 3D bioprinter. Cardiac patches were analyzed with light and video microscopy, immunohistochemistry, immunofluorescence, cell viability assays and optical electrical mapping. Cardiac tissue patches of all cell ratios beat spontaneously after 3D bioprinting. Patches exhibited ventricular-like action potential waveforms and uniform electrical conduction throughout the patch. Conduction velocities were higher and action potential durations were significantly longer in patches containing a lower percentage of FBs. Immunohistochemistry revealed staining for CM, FB and EC markers, with rudimentary CD31+ blood vessel formation. Immunofluorescence revealed the presence of Cx43, the main cardiac gap junction protein, localized to cell-cell borders. In vivo implantation suggests vascularization of 3D bioprinted cardiac patches with engraftment into native rat myocardium. This constitutes a significant step towards a new generation of stem cell-based treatment for heart failure.

28 July 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TFTakuma Fukunishi
Takuma Fukunishi
CBCameron A Best
Cameron A Best
TSTadahisa Sugiura
Tadahisa Sugiura
TSToshihiro Shoji
Toshihiro Shoji
TYTai Yi
Tai Yi
NHNarutoshi Hibino
Narutoshi Hibino
Tissue engineered vascular grafts (TEVGs) have the potential to overcome the issues faced by existing small diameter prosthetic grafts by providing a biodegradable scaffold where the patient’s own cells can engraft and form functional neotissue. However, applying classical approaches to create arterial TEVGs using slow degrading materials with supraphysiological mechanical properties, typically results in limited host cell infiltration, poor remodeling, stenosis, and calcification. The purpose of this study is to evaluate the feasibility of novel small diameter arterial TEVGs created using fast degrading material. A 1.0mm and 5.0mm diameter TEVGs were fabricated with electrospun polycaprolactone (PCL) and chitosan (CS) blend nanofibers. The 1.0mm TEVGs were implanted in mice (n = 3) as an unseeded infrarenal abdominal aorta interposition conduit., The 5.0mm TEVGs were implanted in sheep (n = 6) as an unseeded carotid artery (CA) interposition conduit. Mice were followed with ultrasound and sacrificed at 6 months. All 1.0mm TEVGs remained patent without evidence of thrombosis or aneurysm formation. Based on small animal outcomes, sheep were followed with ultrasound and sacrificed at 6 months for histological and mechanical analysis. There was no aneurysm formation or calcification in the TEVGs. 4 out of 6 grafts (67%) were patent. After 6 months in vivo, 9.1 ± 5.4% remained of the original scaffold. Histological analysis of patent grafts demonstrated deposition of extracellular matrix constituents including elastin and collagen production, as well as endothelialization and organized contractile smooth muscle cells, similar to that of native CA. The mechanical properties of TEVGs were comparable to native CA. There was a significant positive correlation between TEVG wall thickness and CD68+ macrophage infiltration into the scaffold (R2 = 0.95, p = 0.001). The fast degradation of CS in our novel TEVG promoted excellent cellular infiltration and neotissue formation without calcification or aneurysm. Modulating host macrophage infiltration into the scaffold is a key to reducing excessive neotissue formation and stenosis.

1 April 2020 in Science Translational Medicine
Verified
Journal Article
Closed access
JDJoseph D. Drews
Joseph D. Drews
VPVictoria K. Pepper
Victoria K. Pepper
CBCameron A. Best
Cameron A. Best
JSJason M. Szafron
Jason M. Szafron
JCJohn P. Cheatham
John P. Cheatham
CBChristopher K. Breuer
Christopher K. Breuer
Computational modeling and ovine data reveal spontaneous reversal of early tissue-engineered vascular graft stenosis, with clinical implications.

1 April 2017 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
TFTakuma Fukunishi
Takuma Fukunishi
CBCameron A. Best
Cameron A. Best
TSTadahisa Sugiura
Tadahisa Sugiura
JOJustin Opfermann
Justin Opfermann
COChin Siang Ong
Chin Siang Ong
NHNarutoshi Hibino
Narutoshi Hibino

21 February 2024 in Nature
Verified
Journal Article
Closed access
PDF file
PLPengju Li
Pengju Li
JZJing Zhang
Jing Zhang
HHHidenori Hayashi
Hidenori Hayashi
JYJiping Yue
Jiping Yue
WLWen Li
Wen Li
BTBozhi Tian
Bozhi Tian

3 September 2019 in Journal of Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Closed access
PDF file
EYEnoch Yeung
Enoch Yeung
TFTakuma Fukunishi
Takuma Fukunishi
YBYang Bai
Yang Bai
DBDjahida Bedja
Djahida Bedja
IPIsaree Pitaktong
Isaree Pitaktong
NHNarutoshi Hibino
Narutoshi Hibino