Heba Lakany

Dr. Heba Lakany

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
RMRadhika Menon
Radhika Menon
GCGaetano Di Caterina
Gaetano Di Caterina
HLHeba Lakany
Heba Lakany
LPLykourgos Petropoulakis
Lykourgos Petropoulakis
BCBernard A. Conway
Bernard A. Conway
JSJohn J. Soraghan
John J. Soraghan
Advanced forearm prosthetic devices employ classifiers to recognize different electromyography (EMG) signal patterns, in order to identify the user's intended motion gesture. The classification accuracy is one of the main determinants of real-time controllability of a prosthetic limb and hence the necessity to achieve as high an accuracy as possible. In this paper, we study the effects of the temporal and spatial information provided to the classifier on its off-line performance and analyze their inter-dependencies. EMG data associated with seven practical hand gestures were recorded from partial-hand and trans-radial amputee volunteers as well as able-bodied volunteers. An extensive investigation was conducted to study the effect of analysis window length, window overlap, and the number of electrode channels on the classification accuracy as well as their interactions. Our main discoveries are that the effect of analysis window length on classification accuracy is practically independent of the number of electrodes for all participant groups; window overlap has no direct influence on classifier performance, irrespective of the window length, number of channels, or limb condition; the type of limb deficiency and the existing channel count influence the reduction in classification error achieved by adding more number of channels; partial-hand amputees outperform trans-radial amputees, with classification accuracies of only 11.3% below values achieved by able-bodied volunteers.

1 April 2011 in Brain and Language
Verified
Journal Article
Closed access
BMBrian Murphy
Brian Murphy
MPMassimo Poesio
Massimo Poesio
Francesca BovoloFrancesca Bovolo
Francesca Bovolo
LBLorenzo Bruzzone
Lorenzo Bruzzone
MDMichele Dalponte
Michele Dalponte
HLHeba Lakany
Heba Lakany

1 May 2008 in Pattern Recognition
Verified
Journal Article
Closed access
HLHeba Lakany
Heba Lakany

1 September 2014 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
PMPaul McCool
Paul McCool
NCNavin Chatlani
Navin Chatlani
LPLykourgos Petropoulakis
Lykourgos Petropoulakis
JSJohn J. Soraghan
John J. Soraghan
RMRadhika Menon
Radhika Menon
HLHeba Lakany
Heba Lakany
This paper presents a new electromyography activity detection technique in which 1-D local binary pattern histograms are used to distinguish between periods of activity and inactivity in myoelectric signals. The algorithm is tested on forearm surface myoelectric signals occurring due to hand gestures. The novel features of the presented method are that: 1) activity detection is performed across multiple channels using few parameters and without the need for majority vote mechanisms, 2) there are no per-channel thresholds to be tuned, which makes the process of activity detection easier and simpler to implement and less prone to errors, 3) it is not necessary to measure the properties of the signal during a quiescent period before using the algorithm. The algorithm is compared to other offline single- and double-threshold activity detection methods and, for the data sets tested, it is shown to have a better overall performance with greater tolerance to the noise in the real data set used.

16 January 2025 in BMC Geriatrics
Verified
Journal Article
Open access
PDF file
PTPing-Chen Tsai
Ping-Chen Tsai
AAAsangaedem Akpan
Asangaedem Akpan
KTKea-Tiong Tang
Kea-Tiong Tang
HLHeba Lakany
Heba Lakany
Background: Brain-computer interface (BCI) offers promising solutions to cognitive enhancement in older people. Despite the clear progress received, there is limited evidence of BCI implementation for rehabilitation. This systematic review addresses BCI applications and challenges in the standard practice of EEG-based neurofeedback (NF) training in healthy older people or older people with mild cognitive impairment (MCI). Methods: Articles were searched via MEDLINE, PubMed, SCOPUS, SpringerLink, and Web of Science. 16 studies between 1st January 2010 to 1st November 2024 are included after screening using PRISMA. The risk of bias, system design, and neurofeedback protocols are reviewed. Results: The successful BCI applications in NF trials in older people were biased by the randomisation process and outcome measurement. Although the studies demonstrate promising results in effectiveness of research-grade BCI for cognitive enhancement in older people, it is premature to make definitive claims about widespread BCI usability and applicability. Significance: This review highlights the common issues in the field of EEG-based BCI for older people. Future BCI research could focus on trial design and BCI performance gaps between the old and the young to develop a robust BCI system that compensates for age-related declines in cognitive and motor functions.

1 October 2013
Verified
Conference Paper
Closed access
CWChi-Hsu Wu
Chi-Hsu Wu
HLHeba Lakany
Heba Lakany
Most visual stimulators used in steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) to elicit SSVEP response are set close to the BCI system limiting the portability and the applications of the system. Our aim is to develop a portable SSVEP based BCI adaptable to the change of the viewing distance of the stimulator which will allow users to operate the BCI without being restricted to a particular area. This study (1) investigates the impact of the distance between the user and the visual stimulator on the SSVEP response and (2) develops a portable visual stimulator that would adapt to change of distance. The finding suggests that a distance adaptable SSVEP based BCI is achievable by changing the intensity of visual stimulator to correspond to the change of the viewing distance. It is hoped that this work can help SSVEP BCI design and broaden its potential applications and users.