Jiahui Wu

Jiahui Wu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
HLHui Liang
Hui Liang
JWJiahui Wu
Jiahui Wu
HZHua Zhang
Hua Zhang
JYJian Yang
Jian Yang
To solve the problem of feature selection and error correction after mode decomposition and improve the ability of power load forecasting models to capture complex time series information, a two-stage short-term power load forecasting method based on recursive feature elimination with a cross validation (RFECV) algorithm and time convolution network–efficient channel attention mechanism–long short-term memory network (TCN–ECA–LSTM) is presented. First, the load sequence is decomposed into a relatively stable set of modal components using variational mode decomposition. Then, the RFECV-based method filters the feature set of each modal component to construct the best feature set. Finally, a two-stage prediction model based on TCN–ECA–LSTM is established. The first stage predicts each modal component and the second stage reconstructs the load forecast based on the predicted value of the previous stage. This paper takes actual data from New South Wales, Australia, as an example, and the results show that the method proposed in this paper can build the feature set reliably and efficiently and has a higher accuracy than the conventional prediction model.

11 February 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LQLiu Qi
Liu Qi
JWJiahui Wu
Jiahui Wu
WHWang Haiyun
Wang Haiyun
ZHZhang Hua
Zhang Hua
YJYang Jian
Yang Jian
The doubly-fed induction generator (DFIG) with virtual inertia control and reactive damping control gives a renewable energy generation system inertia and damping characteristics similar to those of a thermal power plant, and the parameters of the control strategy have a direct impact on the small-signal stability of the system. This paper firstly introduces the operating characteristics and control strategies of DFIG-based damping control and virtual inertia control, establishes a small-signal model of the control-based DFIG integrated interconnected system, and investigates the effects of virtual inertia and reactive damping values on the small-signal stability of the system; then, the maximum damping ratio of the interval oscillation mode in small disturbance analysis is taken as the optimization objective, and the control parameters are the optimization variables. An optimization method of inertia and damping parameters is established for improving the small disturbance stability of the system. The results show that the optimization procedure could improve the damping ratio of the interval oscillation mode while ensuring the system frequency. The effects of virtual inertia and reactive damping values on the small signal stability of the system are investigated, and an optimal allocation model and method for virtual inertia used to improve the small disturbance stability of the system is proposed.

4 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MYMingzhu Yan
Mingzhu Yan
JWJiahui Wu
Jiahui Wu
HJHuan Jiang
Huan Jiang
YKYang Kou
Yang Kou
WZWei Zhao
Wei Zhao
The increasing scale of wind power access to the grid makes it important to identify weak links in the system to prevent major outages. In order to analyze the vulnerability of grid nodes, this paper proposes a dynamic comprehensive evaluation method considering system uniformity, and establishes a comprehensive assessment model of node vulnerability based on wind power grid-connectedness, based on which the vulnerability of wind power-containing power systems is studied. Firstly, the improved weighted power entropy index is selected for the phenomena of system current instability and line overloading, and the comprehensive index set of node vulnerability is constructed by considering the structural and state characteristics, and the subjective and objective weights are calculated by using the hierarchical analysis method and the CRITIC method. Subsequently, the Dagum-Gini coefficient method is utilized to reflect the homogeneity of the system, and a comprehensive evaluation method based on the VIKOR method is used to confirm the ordering of critical nodes that have the greatest impact on the system and have a high failure rate. Finally, the proposed method is applied to the study of node vulnerability of wind-containing power systems. The feasibility of the above methodology is verified by a modified IEEE-118 test system with test simulations.

13 September 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ZRZhibo Rao
Zhibo Rao
JWJiahui Wu
Jiahui Wu
GLGuodong Li
Guodong Li
HWHaiyun Wang
Haiyun Wang
Accurately detecting voltage faults is essential for ensuring the safe and stable operation of energy storage power station systems. To swiftly identify operational faults in energy storage batteries, this study introduces a voltage anomaly prediction method based on a Bayesian optimized (BO)-Informer neural network. Firstly, the temporal characteristics and actual data collected by the battery management system (BMS) are considered to establish a long-term operational dataset for the energy storage station. The Pearson correlation coefficient (PCC) is used to quantify the correlations between these data. Secondly, an Informer neural network with BO hyperparameters is used to build the voltage prediction model. The performance of the proposed model is assessed by comparing it with several state-of-the-art models. With a 1 min sampling interval and one-step prediction, trained on 70% of the available data, the proposed model reduces the root mean square error (RMSE), mean square error (MSE), and mean absolute error (MAE) of the predictions to 9.18 mV, 0.0831 mV, and 6.708 mV, respectively. Furthermore, the influence of different sampling intervals and training set ratios on prediction results is analyzed using actual grid operation data, leading to a dataset that balances efficiency and accuracy. The proposed BO-based method achieves more precise voltage abnormity prediction than the existing methods.

13 June 2024 in Electronics
Verified
Journal Article
Open access
PDF file
JWJiahui Wu
Jiahui Wu
JLJiangyong Li
Jiangyong Li
HWHaiyun Wang
Haiyun Wang
GLGuodong Li
Guodong Li
YRYalun Ru
Yalun Ru
In the conventional dual-loop vector control strategy of Voltage Source Converter-based High Voltage Direct Current (VSC-HVDC) systems employed in offshore wind farms, challenges such as complex PI parameter-tuning and slow response speed exist. Furthermore, a single-phase bridge-arm fault in the converter station can lead to a change in system parameters, resulting in the failure of the original control strategy. Hence, this paper proposes a fault-tolerant control strategy for grid-connected offshore wind farms, based on model predictive control (MPC). Firstly, the predictive models for both normal and fault-tolerant states of the grid-side converter station are established based on the system structure of the grid-side converter station and a super-local model. Subsequently, a cost function is constructed using the power error, with the optimization objective set as the value function. This approach allows for accurate prediction of the future switching states of the grid-tied inverter to track the reference power. Finally, a simulation model of the offshore wind power grid system is established in the MATLAB/Simulink (2022a) environment. The results demonstrate that the grid-side converter station can effectively operate in a fault-tolerant manner under the proposed control strategy, thereby enhancing the disturbance resistance and fault-recovery capabilities of the offshore wind VSC-HVDC system.

26 February 2024 in Electronics
Verified
Journal Article
Open access
PDF file
MLMingyang Liu
Mingyang Liu
JWJiahui Wu
Jiahui Wu
QZQiang Zhang
Qiang Zhang
HZHongjuan Zheng
Hongjuan Zheng
In this paper, a fault recovery strategy for a distribution network based on a pigeon-inspired optimization (PIO) algorithm is proposed to improve the recoverability of the network considering the increased proportion of distributed energy resources. First, an improved Kruskal algorithm-based island partitioning scheme is proposed considering the electrical distance and important load level during the island partitioning process. Secondly, a mathematical model of fault recovery is established with the objectives of reducing active power losses and minimizing the number of switching actions. The conventional PIO algorithm is improved using chaos, reverse strategy, and Cauchy perturbation strategy, and the improved pigeon-inspired optimization (IPIO) algorithm is applied to solve the problem of fault recovery of the distribution network. Finally, simulation analysis is carried out to verify the effectiveness of the proposed PIO algorithm considering a network restauration problem after fault. The results show that compared with traditional algorithms, the proposed PIO algorithm has stronger global search capability, effectively improving the node voltage after restauration and reducing circuit loss.