Scott C. E. Brandon

Dr. Scott C. E. Brandon

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2019 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
EBErica Beaucage-Gauvreau
Erica Beaucage-Gauvreau
WRWilliam S. P. Robertson
William S. P. Robertson
SBScott C. E. Brandon
Scott C. E. Brandon
RFRobert Fraser
Robert Fraser
BFBrian J. C. Freeman
Brian J. C. Freeman
CJClaire F. Jones
Claire F. Jones
There is currently no validated full-body lifting model publicly available on the OpenSim modelling platform to estimate spinal loads during lifting. In this study, the existing full-body-lumbar-spine model was adapted and validated for lifting motions to produce the lifting full-body model. Back muscle activations predicted by the model closely matched the measured erector spinae activation patterns. Model estimates of intradiscal pressures and in vivo measurements were strongly correlated. The same spine loading trends were observed for model estimates and reported vertebral body implant measurements. These results demonstrate the suitability of this model to evaluate changes in lumbar loading during lifting.


1 June 2019 in The Knee
Verified
Journal Article
Closed access
SBScott C. E. Brandon
Scott C. E. Brandon
MBMarcus J. Brown
Marcus J. Brown
ACAllison L. Clouthier
Allison L. Clouthier
ACAaron Campbell
Aaron Campbell
Jim RichardsJim Richards
Jim Richards
KDKevin J. Deluzio
Kevin J. Deluzio

20 September 2022 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
VBValerie V. Bauman
Valerie V. Bauman
SBScott C. E. Brandon
Scott C. E. Brandon
Machine learning-based activity and gait phase recognition algorithms are used in powered motion assistive devices to inform control of motorized components. The objective of this study was to develop a supervised multiclass classifier to simultaneously detect activity and gait phase (stance, swing) in real-world walking, stair ascent, and stair descent using inertial measurement data from the thigh and shank. The intended use of this algorithm was for control of a motion assistive device local to the knee. Using data from 80 participants, two decision trees and five long short-term memory (LSTM) models that each used different feature sets were initially tested and evaluated using a novel performance metric: proportion of perfectly classified strides (PPCS). Based on the PPCS of these initial models, five additional posthoc LSTM models were tested. Separate models were developed to classify (i) both activity and gait phase simultaneously (one model predicting six states), and (ii) activity-specific models (three individual binary classifiers predicting stance/swing phases). The superior activity-specific model had an accuracy of 98.0% and PPCS of 55.7%. The superior six-phase model used filtered inertial measurement data as its features and a median filter on its predictions and had an accuracy of 92.1% and PPCS of 22.9%. Pooling stance and swing phases from all activities and treating this model as a binary classifier, this model had an accuracy of 97.1%, which may be acceptable for real-world lower limb exoskeleton control if only stance and swing gait phases must be detected. Keywords: machine learning, deep learning, inertial measurement unit, activity recognition, gait.

6 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JLJesse Lozinski
Jesse Lozinski
HHHamidreza Heidary
Hamidreza Heidary
SBScott C. E. Brandon
Scott C. E. Brandon
Amin KomeiliAmin Komeili
Amin Komeili
Dynamic loads have short and long-term effects in the rehabilitation of lower limb joints. However, an effective exercise program for lower limb rehabilitation has been debated for a long time. Cycling ergometers were instrumented and used as a tool to mechanically load the lower limbs and track the joint mechano-physiological response in rehabilitation programs. Current cycling ergometers apply symmetrical loading to the limbs, which may not reflect the actual load-bearing capacity of each limb, as in Parkinson’s and Multiple Sclerosis diseases. Therefore, the present study aimed to develop a new cycling ergometer capable of applying asymmetric loads to the limbs and validate its function using human tests. The instrumented force sensor and crank position sensing system recorded the kinetics and kinematics of pedaling. This information was used to apply an asymmetric assistive torque only to the target leg using an electric motor. The performance of the proposed cycling ergometer was studied during a cycling task at three different intensities. It was shown that the proposed device reduced the pedaling force of the target leg by 19% to 40%, depending on the exercise intensity. This reduction in pedal force caused a significant reduction in the muscle activity of the target leg (p < 0.001), without affecting the muscle activity of the non-target leg. These results demonstrated that the proposed cycling ergometer device is capable of applying asymmetric loading to lower limbs, and thus has the potential to improve the outcome of exercise interventions in patients with asymmetric function in lower limbs.

1 February 2020 in Journal of Biomechanics
Verified
Journal Article
Closed access
EBErica Beaucage-Gauvreau
Erica Beaucage-Gauvreau
SBScott C. E. Brandon
Scott C. E. Brandon
WRWilliam S.P. Robertson
William S.P. Robertson
RFRobert Fraser
Robert Fraser
BFBrian J.C. Freeman
Brian J.C. Freeman
CJClaire F. Jones
Claire F. Jones