Textile-reinforced concrete (TRC) is highly anticipated as an alternative to reinforced concrete due to its ability to enable lightweight design, free formability, and improved ductility. In this study, TRC panel test specimens were fabricated and four-point loading flexural tests were performed to examine the flexural characteristics of TRC panels reinforced with carbon fabric, and to investigate the effect of the fabric reinforcement ratio, anchorage length, and surface treatment of fabric. Furthermore, the flexural behavior of the test specimens was numerically analyzed using the general section analysis concept of reinforced concrete and compared with the experimental results. Due to bond failure between the carbon fabric and the concrete matrix, the TRC panel showed a large decrease in flexural performance in terms of flexural stiffness, flexural strength, cracking behavior, and deflection. This low performance was improved by increasing the fabric reinforcement ratio, anchoring length, and sand–epoxy surface treatment of the anchorage. Comparing the numerical calculation results with the experimental results, the deflection of the experimental results was approximately 50% larger than the numerical calculation results. This is because the perfect bond between the carbon fabric and the concrete matrix failed, and slip occurred.
Bridges are key social overhead capital facilities with a direct impact on citizen safety and the socioeconomic development of a country. Many bridges in South Korea were completed during the nation’s period of rapid economic growth in the 1970s and 1980s, meaning that bridge aging is now accelerating and should be of real concern. Based on records of other highly developed countries not having adequate maintenance systems for old bridges and consequently experiencing a number of tragic bridge collapses, Korea is at risk of following suit. Being able to measure the efficiency of bridge management considering economic and social values is therefore critical. In this work, a qualitative bridge maintenance priority evaluation model using open-source bridge information was developed. The model was evaluated by applying it to eight actual bridges located in Daegu Metropolitan City, Korea. It is concluded that aging bridge maintenance and management can be performed more efficiently and reliably if the model proposed in this work is used.
Bridges are a key component of transportation infrastructure, playing a critical role in socioeconomic development and public safety. In South Korea, many bridges were constructed during the nation’s economic boom in the 1970s and 1980s, meaning that the number of aging bridges with a service life of over 30 years now accounts for approximately 17% of all bridges in the country. Unfortunately, there have been instances of bridge collapses due to the lack of a proper maintenance system for these aging structures. To address this issue, a priority evaluation model called the Bridge Health Index (BHI) was developed to assess maintenance prioritization. In this study, nine actual bridges were evaluated using the proposed model, with the aim of ensuring that the maintenance and management of bridges at risk can be conducted efficiently and reliably.
Carbon-fiber-reinforced polymer (CFRP) cables have emerged as promising alternatives to conventional prestressing tendons because of their high tensile strength, excellent corrosion resistance, and low self-weight. Their use is particularly advantageous in infrastructure exposed to aggressive environments, such as chloride-induced corrosion, where improved durability and reduced maintenance are critically required. In this study, a 10 mm diameter round-bar-type CFRP cable was developed using a pultrusion process, and its applicability to structural systems was comprehensively evaluated through material testing and field implementation. Mechanical performance was assessed through tensile, relaxation, and fatigue tests. The developed CFRP cable exhibited an average tensile strength of 3019 MPa and an elastic modulus of 176.9 GPa, demonstrating mechanical properties comparable to or better than those of conventional prestressing tendons. The final relaxation ratio was measured as 2.25%, satisfying the low-relaxation criterion specified in KS D 7002. In the fatigue test, the cable sustained 2,000,000 loading cycles under a stress range corresponding to 60–66% of the ultimate tensile strength without fracture or significant stiffness degradation, confirming its excellent fatigue durability. In addition, the developed CFRP cable was implemented in a cable-net structure to verify its constructability and structural applicability in practice. The field application confirmed that the lightweight CFRP cable enabled convenient transportation and installation, while stable prestress introduction was achieved using the same tensioning procedure as that for conventional steel cable systems. The results demonstrate the integrated feasibility of the developed CFRP cable in terms of both material performance and practical structural application. This study provides experimental evidence supporting the structural use of CFRP tendons and offers a technical basis for the future development of design provisions and broader infrastructure applications.
Carbon-fiber reinforced polymer (CFRP) tendons have attracted increasing attention as corrosion-resistant prestressing elements for prestressed concrete and cable-supported structures; however, their practical implementation requires reliable verification of long-term mechanical performance and anchorage reliability. In this study, a 9.5 mm pultruded CFRP tendon and compression-type anchorage system were developed and experimentally evaluated through relaxation, creep rupture, and fatigue tests. The tendon exhibited a tensile strength of 2501 MPa and an elastic modulus of 132.5 GPa. Relaxation tests were conducted at an initial load corresponding to 70% of the ultimate tensile capacity, and the measured relaxation loss after 1000 h was 1.02%. Based on logarithmic regression of the measured data, the relaxation loss at 1,000,000 h was estimated to be 2.11%; however, this value should be interpreted as an extrapolated long-term estimate rather than a directly verified result. Creep rupture tests performed at load ratios of 82.4–100.0% yielded an estimated 1,000,000 h creep rupture load ratio of approximately 80%, although the prediction is subject to uncertainty because of the limited number of specimens and scatter in rupture times. Fatigue tests indicated that the CFRP tendon–anchorage assembly maintained stable performance up to 2,000,000 cycles without measurable degradation in elastic stiffness under the adopted loading conditions. These results suggest that the developed CFRP tendon–anchorage system has promising potential for prestressing applications, while further long-term tests with a larger number of specimens are required to improve the statistical reliability of the extrapolated relaxation and creep rupture predictions.