Flávio Henrique Baggio Aguiar

Prof. Flávio Henrique Baggio Aguiar

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2005 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
CLCarolina Rodrigues Lazzari
Carolina Rodrigues Lazzari
DLDébora Alves Nunes Leite Lima
Débora Alves Nunes Leite Lima
GAGlaucia Maria Bovi Ambrosano
Glaucia Maria Bovi Ambrosano
JLJosé Roberto Lovadino
José Roberto Lovadino
Resin composite shades and resin composite polymerization performed with a distanced light tip are factors that can affect polymerization effectiveness. Thisin vitro study aimed to evaluate the influence of curing tip distance and resin shade on the microhardness of a hybrid resin composite (Z250 - 3M ESPE). Forty-five resin composite specimens were randomly prepared and divided into nine experimental groups (n = 5): three curing tip distances (2 mm, 4 mm, and 8 mm) and three resin shades (A1, A3.5, and C2). All samples were polymerized with a continuous output at 550 mW/cm². After 24 hours, Knoop microhardness measurements were obtained on the top and bottom surfaces of the sample, with a load of 25 grams for 10 seconds. Five indentations were performed on each surface of each sample. Results showed that bottom surface samples light-cured at 2 mm and 4 mm presented significantly higher hardness values than samples light-cured at 8 mm. The resin shade A1 presented higher hardness values and was statistically different from C2. The resin shade A3.5 did not present statistical differences from A1 and C2. For the top surface, there were no statistical differences among the curing tip distances. For all experimental conditions, the top surface showed higher hardness values than the bottom surface. It was concluded that light curing tip distance and resin shade are important factors to be considered for obtaining adequate polymerization.

1 June 2015 in Dental Materials
Verified
Journal Article
Closed access
TSThiago Henrique Scarabello Stape
Thiago Henrique Scarabello Stape
LTLeo Tjäderhane
Leo Tjäderhane
MMMarcelo Rocha Marques
Marcelo Rocha Marques
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
LMLuís Roberto Marcondes Martins
Luís Roberto Marcondes Martins

1 April 2011 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
DMDiogo de Azevedo Miranda
Diogo de Azevedo Miranda
CBCarlos Eduardo dos Santos Bertoldo
Carlos Eduardo dos Santos Bertoldo
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
DLDébora Alves Nunes Leite Lima
Débora Alves Nunes Leite Lima
JLJosé Roberto Lovadino
José Roberto Lovadino
The aim of this in vitro study was to evaluate the effect of different mouthwashes on superficial roughness and Knoop hardness of two resin composites. Eighty specimens (6 mm Ø and 2 mm height) were prepared and divided into eight experimental groups (n = 10) according to the resin composites (4 Seasons and Esthet X), and storage solutions (G1 - Distilled water; G2 - Colgate Plax Overnight; G3 - Colgate Plax Alcohol Free; and G4 - Colgate Plax Whitening). The initial hardness and roughness readings (T1) were measured and then the specimens were stored in 2 mL of mouthwash for 12 h (T2) and 24 h (T3). The data were analyzed with repeat-measures two-way ANOVA and Tukey's test (α = 5%). Regardless of the type of solution and time of exposure, there was no statistical difference for roughness between the resins (p = 0.44). G4 and G8 presented higher roughness means than G1, G3, G5 and G7, after 12 and 24 hours of immersion. For Knoop microhardness analysis, there was a significant reduction for all groups after 12 hours and 24 hours. We conclude that the mouthwashes containing hydrogen peroxide and/or alcohol decrease the microhardness of the resins tested; however, the mouthwash containing hydrogen peroxide had a higher deleterious effect on roughness.

6 April 2009 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
DLDébora Alves Nunes Leite Lima
Débora Alves Nunes Leite Lima
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
PLPriscila Christiane Suzy Liporoni
Priscila Christiane Suzy Liporoni
EMEgberto Munin
Egberto Munin
GAGláucia Maria Bovi Ambrosano
Gláucia Maria Bovi Ambrosano
JLJosé Roberto Lovadino
José Roberto Lovadino

1 December 2005 in Dental Materials
Verified
Journal Article
Closed access
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
ABAline T.B. Braceiro
Aline T.B. Braceiro
GAGláucia M.B. Ambrosano
Gláucia M.B. Ambrosano
JLJosé R. Lovadino
José R. Lovadino

1 February 2012 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
RPRenata Corrêa Pascotto
Renata Corrêa Pascotto
NPNúbia Pini
Núbia Pini
FAFlávio Henrique Baggio Aguiar
Flávio Henrique Baggio Aguiar
DLDébora Alves Nunes Leite Lima
Débora Alves Nunes Leite Lima
JLJosé Roberto Lovadino
José Roberto Lovadino
RTRaquel Sano Suga Terada
Raquel Sano Suga Terada
Peer reviewed article authored by (Pini NP, Aguiar FHB, Lima DAN, Lovadino JR, Terada RS, Pascotto RC). Read article or submit your manuscript for publishing.