Coded aperture 3D imaging techniques have been rapidly evolving in recent years. The two main directions of evolution are in aperture engineering to generate the optimal optical field and in the development of a computational reconstruction method to reconstruct the object’s image from the intensity distribution with minimal noise. The goal is to find the ideal aperture–reconstruction method pair, and if not that, to optimize one to match the other for designing an imaging system with the required 3D imaging characteristics. The Lucy–Richardson–Rosen algorithm (LR2A), a recently developed computational reconstruction method, was found to perform better than its predecessors, such as matched filter, inverse filter, phase-only filter, Lucy–Richardson algorithm, and non-linear reconstruction (NLR), for certain apertures when the point spread function (PSF) is a real and symmetric function. For other cases of PSF, NLR performed better than the rest of the methods. In this tutorial, LR2A has been presented as a generalized approach for any optical field when the PSF is known along with MATLAB codes for reconstruction. The common problems and pitfalls in using LR2A have been discussed. Simulation and experimental studies for common optical fields such as spherical, Bessel, vortex beams, and exotic optical fields such as Airy, scattered, and self-rotating beams have been presented. From this study, it can be seen that it is possible to transfer the 3D imaging characteristics from non-imaging-type exotic fields to indirect imaging systems faithfully using LR2A. The application of LR2A to medical images such as colonoscopy images and cone beam computed tomography images with synthetic PSF has been demonstrated. We believe that the tutorial will provide a deeper understanding of computational reconstruction using LR2A.
The current study concentrated on the green synthesis of Zinc-titanium dioxide nano-composite (Zn-TiO2 NC) through the use of lemon extract, optimizing the different experimental factors required for the formation and stability of nanocomposite. The preparation of nanocomposite was confirmed by the observation of the colour change and the surface plasmon resonance band was found at 380 nm, utilizing UV-Visible analysis. The TEM analysis, the morphological features of the prepared nanocomposite was identified to be spherical shape with mean particle size of 25 nm. In addition, the antibacterial, antioxidant, and anti-inflammatory activity of this nano-composite were also investigated. The biosynthesized nanocomposite showed excellent antibacterial activity against S. mitis and S. mutans. The obtained results indicate that the antioxidant and anti-inflammatory activity of this nanocomposite is significant. This bioactive nanocomposite can be used as an effective antibacterial, antioxidant and anti-inflammatory agent in biomedical and pharmacological fields for future applications.
16 April 2024 in Journal of Pharmacy and Bioallied Sciences
To compare the patient acceptance between fixed orthodontic appliances and clear aligners. An electronic search was completed in PubMed, Cochrane Database, Web of Science, Scopus, Lilacs, Google Scholar, and Open Grey databases without any restrictions until August 23. All comparative study types contrasting patient perception between clear aligners and fixed appliances were included. After removal of duplicates, exclusion by title and abstract, and reading the full text, only eight articles were included. The studies used an observational questionnaire study design. Of the observational studies, one was retrospective and three prospective, one online survey, and the other three cross sectional. Though the response varied in terms of patient preference and acceptance, it was found that clear aligners have a positive impact with respect to quality of life, tolerance, and improved confidence. However, there is not enough evidence to make a final conclusion about treatment outcomes.
1 January 2025 in Indian Journal of Dental Research
Background: Bisphenol A (BPA) monomer is used during the production of a wide variety of orthodontic materials such as composites, aesthetic brackets, and thermoplastic aligners; its release from incomplete polymerisation and resin degradation poses serious health risks. Hence, this study aims to assess BPA release from different aligners at various time intervals of its usage in an in vitro model. Aim and Objectives: To qualitatively and quantitatively determine BPA released from five different orthodontic aligners, at different time intervals. Materials and Methods: Five different orthodontic aligners, namely Dentcare aligner, Invisalign aligner, SD align, Smile aligner, and TAC aligners, were evaluated for BPA release by subjecting the aligners to surface abrasion, immersing in artificial saliva, and subjecting to thermal shock treatment to simulate oral environment at various time intervals (24 hours, 7 days, and 10 days) using gas-phase chromatography. Statistical Analysis Used: Descriptive statistics (frequency and percentages) were employed to describe the study results. Result: BPA was not detected and thus could not be analysed in the present study at different time points. The other elements were identified, which were totally different from one another at each time points. Conclusion: It is concluded that BPA was not released from the various aligners at any time intervals. The presence of other components such as diethyl phthalate (DEP), which is more or less similar to BPA in terms of inducing toxicity to the liver and other tissues, is a matter of concern and needs further research.
Coded aperture 3D imaging techniques have been rapidly evolving in the recent years. The two main directions of evolution are in aperture engineering to generate the optimal optical field and in development of computational reconstruction to reconstruct the object’s image from the intensity distribution with a minimal noise. The goal is to find the ideal aperture-reconstruction method pair and if not, to optimize one to match the other for designing an imaging system with required 3D imaging characteristics. Lucy-Richardson-Rosen algorithm (LR2A), a recently developed computational reconstruction method was found to perform better than its predecessors such as matched filter, Weiner filter, phase-only filter, Lucy-Richardson algorithm and non-linear reconstruction (NLR) for certain apertures when the point spread function (PSF) is a real and symmetric function. For other cases of PSF, NLR performed better than the rest of the methods. In this tutorial, LR2A has been presented as a generalized approach for any optical field along with MATLAB codes for reconstruction of any image when the PSF is known. The common problems and pitfalls in using LR2A has been discussed. Simulation and experimental studies for common optical fields such as spherical, Bessel, vortex beams and exotic optical fields such as Airy, scattered and self-rotating beams have been presented. From this study, it can be seen that it is possible to transfer the 3D imaging characteristics from non-imaging type exotic fields to indirect imaging systems faithfully using LR2A. The application of LR2A to medical images such as colonoscopy images and cone beam computed tomography images with synthetic PSF has been demonstrated. We believe that the tutorial will provide a deeper understanding of computational reconstruction using LR2A.
1 January 2019 in International Journal of Orthodontic Rehabilitation
Stem cell (SC) therapy has become a buzz word in several debilitating diseases in medicine. This rapidly evolving cutting-edge technology has slowly extended its tentacles in dentistry without sparing orthodontics. There are several conditions in orthodontics which are only being partly answered by human-engineered techniques. With the hope of getting a complete solution to several such problems, research in SC therapy has gained momentum in orthodontics for the past few decades. Electronic databases were searched for the material collection; language restriction was not followed. The following keywords were used: stem cell and orthodontics. The search was not limited to any particular type of study design. This review article describes various possible areas in orthodontia where SC therapy will and can be applied in future based on the evidence from a collection of several such studies conducted in those areas.