Leonhard Gruber

Dr. Leonhard Gruber


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2022 in Radiology
Verified
Journal Article
Closed access
ALAnna Katharina Luger
Anna Katharina Luger
TSThomas Sonnweber
Thomas Sonnweber
LGLeonhard Gruber
Leonhard Gruber
CSChristoph Schwabl
Christoph Schwabl
KCKatharina Cima
Katharina Cima
GWGerlig Widmann
Gerlig Widmann
One year after the onset of COVID-19 pneumonia, chest CT demonstrated abnormalities, such as subtle subpleural reticulations, ground-glass opacities, or both, in 54% of participants. Background The long-term pulmonary sequelae of COVID-19 is not well known. Purpose To characterize patterns and rates of improvement of chest CT abnormalities 1 year after COVID-19 pneumonia. Mater...

15 April 2023 in European Journal of Radiology
Verified
Journal Article
Open access
MDMartin Daniaux
Martin Daniaux
LGLeonhard Gruber
Leonhard Gruber
TZTobias De Zordo
Tobias De Zordo
SGSabine Geiger-Gritsch
Sabine Geiger-Gritsch
BABirgit Amort
Birgit Amort
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
To compare contrast-enhanced spectral mammography (CESM) with mammography (Mx), ultrasound (US), and magnetic resonance imaging (MRI) regarding breast cancer detection rate and preoperative local staging. This prospective observational, single-centre study included 128 female patients (mean age 55.8 ± 11.5 years) with a newly diagnosed malignant breast tumour during routine US and Mx were prospectively enrolled. CESM and MRI examinations were performed within the study. Analysis included interreader agreement, tumour type and grade distribution, detection rates (DR), imaging morphology, contrast-enhancement and was performed by two independent readers blinded to patient history and histopathological diagnosis. Assessment of local disease extent was compared between modalities via Bland-Altman plots. One-hundred-and-ten tumours were classified as NST (85.9%), 4 as ILC (3.1%) and 10 as DCIS (7.8%). DR was highest for MRI (128/128, 100.0%), followed by US (124/128, 96.9%) and CESM (123/128, 96.1%) and lowest for conventional Mx (106/128, 82.8%) (p = 0.0002). Higher breast density did not negatively affect DR of US, CESM or MRI. Local tumour extent measurements based on CESM (Bland-Altman bias 6.6, standard deviation 30.2) showed comparable estimation results to MRI, surpassing Mx (23.4/43.7) and US (35.4/40.5). Even though detection of multifocality and multicentricity was highest for CESM and MRI (p < 0.0001), second-look rates, i.e., targeted US examinations after MRI or CESM, were significantly lower for CESM (10.2% of cases) compared to MRI (16.2%) with a significantly higher true positive rate for CESM (72.0%) vs. MRI (42.5%). CESM is a viable alternative to MRI for lesion detection and local staging in newly diagnosed malignant breast cancer and provides higher specificity in regard to second-look examinations.

24 February 2021 in CardioVascular and Interventional Radiology
Verified
Journal Article
Open access
PDF file
Alexander LoizidesAlexander Loizides
Alexander Loizides
SHSarah Honold
Sarah Honold
ESElisabeth Skalla-Oberherber
Elisabeth Skalla-Oberherber
LGLeonhard Gruber
Leonhard Gruber
WLWolfgang Löscher
Wolfgang Löscher
Hannes GruberHannes Gruber
Hannes Gruber
Purpose: To present a safety-optimized ultrasound-guided minimal invasive carpal tunnel release (CTR) procedure. Materials and Methods: 104 patients (67 female, 37 male; mean age 60.6 ± 14.3 years, 95% CI 57.9 to 63.4 years) with clinical and electrophysiological verified typical carpal tunnel syndrome were referred for a high-resolution ultrasound of the median nerve and were then consecutively assigned for an ultrasound-guided CTR after exclusion of possible secondary causes of carpal tunnel syndrome such as tumors, tendovaginitis, ganglia and possible contraindications (e.g., crossing collateral vessels, nerve variations). Applying a newly adapted and optimized algorithm, basing on the work proposed by Petrover et al. CTR was performed using a button tip cannula which has several safety advantages: On the one hand, the button tip cannula acts as a blunt and atraumatic guiding splint for the subsequent insertion of the hook-knife, and on the other hands, it serves as a “hydro-inflation”-tool, i.e., a fluid-based expansion of the working-space is warranted during the whole procedure whenever needed. Results: In all patients, successful releases were confirmed by the depiction of a completely transected transverse carpal ligament during and in the postoperative ultrasound-controls two weeks after intervention. All patients reported markedly reduction of symptoms promptly after this safety-optimized ultrasound-guided minimal invasive CTR and at the follow-up examination. No complications were evident. Conclusion: The here proposed optimized algorithm assures a reliable and safe ultrasound-guided CTR and thus should be taken into account for this minimal invasive interventional procedure.

1 August 2017 in Clinical Neurophysiology
Verified
Journal Article
Closed access
LGLeonhard Gruber
Leonhard Gruber
ALAlexander Loizides
Alexander Loizides
WLWolfgang Löscher
Wolfgang Löscher
BGBernhard Glodny
Bernhard Glodny
HGHannes Gruber
Hannes Gruber

Verified
Journal Article
Open access
PDF file
PLPietro G. Lacaita
Pietro G. Lacaita
MGMalik Galijasevic
Malik Galijasevic
MSMichael Swoboda
Michael Swoboda
LGLeonhard Gruber
Leonhard Gruber
YSYannick Scharll
Yannick Scharll
GFGudrun Feuchtner
Gudrun Feuchtner
Background/Objectives: Large language models (LLMs), such as ChatGPT, have emerged as potential clinical support tools to enhance precision in personalized patient care, but their reliability in radiological image interpretation remains uncertain. The primary aim of our study was to evaluate the diagnostic accuracy of ChatGPT-4o in interpreting chest X-rays (CXRs) and abdominal X-rays (AXRs) by comparing its performance to expert radiology findings, whilst secondary aims were diagnostic confidence and patient safety. Methods: A total of 500 X-rays, including 257 CXR (51.4%) and 243 AXR (48.5%), were analyzed. Diagnoses made by ChatGPT-4o were compared to expert interpretations. Confidence scores (1–4) were assigned and responses were evaluated for patient safety. Results: ChatGPT-4o correctly identified 345 of 500 (69%) pathologies (95% CI: 64.81–72.9). For AXRs 175 of 243 (72.02%) pathologies were correctly diagnosed (95% CI: 66.06–77.28), while for CXRs 170 of 257 (66.15%) were accurate (95% CI: 60.16–71.66). The highest detection rates among CXRs were observed for pulmonary edema, tumor, pneumonia, pleural effusion, cardiomegaly, and emphysema, and lower rates were observed for pneumothorax, rib fractures, and enlarged mediastinum. AXR performance was highest for intestinal obstruction and foreign bodies, and weaker for pneumoperitoneum, renal calculi, and diverticulitis. Confidence scores were higher for AXRs (mean 3.45 ± 1.1) than CXRs (mean 2.48 ± 1.45). All responses (100%) were considered to be safe for the patient. Interobserver agreement was high (kappa = 0.920), and reliability (second prompt) was moderate (kappa = 0.750). Conclusions: ChatGPT-4o demonstrated moderate accuracy for the interpretation of X-rays, being higher for AXRs compared to CXRs. Improvements are required for its use as efficient clinical support tool.

11 November 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
LGLeonhard Gruber
Leonhard Gruber
Clemens DecristoforoClemens Decristoforo
Clemens Decristoforo
CUChristian Uprimny
Christian Uprimny
Peter HohenbergerPeter Hohenberger
Peter Hohenberger
SSStefan O. Schoenberg
Stefan O. Schoenberg
IVIrene Johanna Virgolini
Irene Johanna Virgolini
Background: Gastrin-releasing peptide receptors (GRPRs) are molecular imaging targets in multiple malignancies. Recently, NeoBOMB1, a 68Ga-labelled antagonist to GRPRs, was developed for PET. Here we report the outcome of a Phase I/IIa clinical trial (EudraCT 2016-002053-38) describing diagnostic properties and covariates influencing uptake of 68Ga-NeoBOMB1 in oligometastatic gastrointestinal stromal tumor (GIST) patients. Methods: Nine patients with advanced GIST using PET/CT (computed tomography) were included. After kit-based 68Ga-NeoBOMB1 preparation with a licensed 68Ge/68Ga generator, 3 MBq/kg body weight were injected intravenously. PET/CT included dynamic and static PET scans 5, 12 and 18 min and 1, 2, and 3–4 h post injection (first six patients) and static PET scans 2 and 3–4 h post injection (last three participants). Tumor targeting was assessed on a per-lesion and per-patient basis. Results: Six patients showed visible radiotracer uptake in at least one tumor lesion. Seventeen out of 37 tumor lesions exhibited significant 68Ga-NeoBOMB1 uptake (median SUVmax 11.8 [range 2.8–51.1] 2 h p.i. and 13.2 [range 2.5–53.8] 3–4 h p.i) and improved lesion-to-background contrast over time. Five lesions (13.5%) were identified only by 68Ga-NeoBOMB1-PET, with no correlation on contrast-enhanced CT. Three patients showed no radiotracer accumulation in any lesions. Tracer uptake correlated with male sex (p < 0.0001), higher body mass index (p = 0.007), and non-necrotic lesion appearance (p = 0.018). There was no association with whole-lesion contrast enhancement, hepatic localization, mutational status, or disease duration. Conclusions: 68Ga-NeoBOMB1-PET exhibits variable tumor uptake in advanced-stage GIST patients, correlating with lesion vitality based on CT contrast uptake, opening the possibility of a theragnostic approach in selected cases.