15 February 2008 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Rafael Gonzalez-LandaetaRafael Gonzalez-Landaeta
Rafael Gonzalez-Landaeta
OCOscar Casas
Oscar Casas
RPRamon Pallas-Areny
Ramon Pallas-Areny
In this paper, a novel technique for heart rate measurement on a standing subject is proposed that relies on electrical impedance variations detected by a plantar interface with booth feet, such as those in some bathroom weighting scales for body composition analysis. Heart-related impedance variations in the legs come from arterial blood circulation and are below 500 mOmega. To detect them, we have implemented a system with a gain in excess of 600, and whose fully differential AC input amplifier has a gain of 4.5 and a common-mode rejection ratio (CMRR) higher than 90 dB at 10 kHz. Differential coherent demodulation based on synchronous sampling yields a signal-to-noise ratio (SNR) of about 54 dB. The system sensitivity is 610 mV/Omega. The technique has been demonstrated on 18 volunteers, whose bioimpedance signal and ECG were simultaneously recorded. A Bland-Altman plot shows a mean bias of -0.2 ms between the RR time intervals obtained from these two signals, which is negligible. The technique is simple and user friendly and does not require any additional sensors or electrodes attached to the body, hence no conductive gel or skin preparation.

18 July 2008 in Physiological Measurement
Verified
Journal Article
Closed access
Rafael Gonzalez-LandaetaRafael Gonzalez-Landaeta
Rafael Gonzalez-Landaeta
OCO Casas
O Casas
RPR Pallàs-Areny
R Pallàs-Areny
We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V(-1) N(-1) to 1670 nV V(-1) N(-1). The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland-Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was +/-21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate.

17 March 2016 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JCJuan Cota-Ruiz
Juan Cota-Ruiz
Pablo RivasPablo Rivas
Pablo Rivas
Ernesto SifuentesErnesto Sifuentes
Ernesto Sifuentes
Rafael Gonzalez-LandaetaRafael Gonzalez-Landaeta
Rafael Gonzalez-Landaeta
In this paper, we present a routing algorithm useful in the realm of centralized range-based localization schemes. The proposed method is capable of estimating the distance between two non-neighboring sensors in multi-hop wireless sensor networks. Our method employs a global table search of sensor edges and recursive functions to find all possible paths between a source sensor and a destination sensor with the minimum number of hops. Using a distance matrix, the algorithm evaluates and averages all paths to estimate a measure of distance between both sensors. Our algorithm is then analyzed and compared with classical and novel approaches, and the results indicate that the proposed approach outperforms the other methods in distance estimate accuracy when used in random and uniform placement of nodes for large-scale wireless networks. Furthermore, the proposed methodology is suitable for the implementation in centralized localization schemes, such as multi-dimensional scaling, least squares, and maximum likelihood to mention a few.

8 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Ernesto SifuentesErnesto Sifuentes
Ernesto Sifuentes
Rafael Gonzalez-LandaetaRafael Gonzalez-Landaeta
Rafael Gonzalez-Landaeta
Cota RuizCota Ruiz
Cota Ruiz
Ferran ReverterFerran Reverter
Ferran Reverter
This paper proposes a microcontroller-based measurement system to detect and confirm the presence of a subject in a chair. The system relies on a single Force Sensing Resistor (FSR), which is arranged in the seat of the chair, that undergoes a sudden resistance change when a subject/object is seated/placed over the chair. In order to distinguish between a subject and an inanimate object, the system also monitors small-signal variations of the FSR resistance caused by respiration. These resistance variations are then directly measured by a low-cost general-purpose microcontroller unit (MCU) without using either an analogue processing stage or an analogue-to-digital converter. Two versions of such a MCU-based circuit are presented: one to prove the concept of the measurement, and another with a smart wake-up (generated by the sudden resistance change) intended to reduce the energy consumption. The feasibility of the proposed measurement system is experimentally demonstrated with subjects of different weight sitting at different postures, and also with objects of different weight. The MCU-based circuit with a smart wake-up shows a standby current consumption of 800 nA, and requires an energy of 125 µJ to carry out the measurement after the wake-up.

18 May 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Ernesto SifuentesErnesto Sifuentes
Ernesto Sifuentes
Rafael Gonzalez-LandaetaRafael Gonzalez-Landaeta
Rafael Gonzalez-Landaeta
Cota RuizCota Ruiz
Cota Ruiz
Ferran ReverterFerran Reverter
Ferran Reverter
This paper evaluates the performance of direct interface circuits (DIC), where the sensor is directly connected to a microcontroller, when a resistive sensor subjected to dynamic changes is measured. The theoretical analysis provides guidelines for the selection of the components taking into account both the desired resolution and the bandwidth of the input signal. Such an analysis reveals that there is a trade-off between the sampling frequency and the resolution of the measurement, and this depends on the selected value of the capacitor that forms the RC circuit together with the sensor resistance. This performance is then experimentally proved with a DIC measuring a magnetoresistive sensor exposed to a magnetic field of different frequencies, amplitudes, and waveforms. A sinusoidal magnetic field up to 1 kHz can be monitored with a resolution of eight bits and a sampling frequency of around 10 kSa/s. If a higher resolution is desired, the sampling frequency has to be lower, thus limiting the bandwidth of the dynamic signal under measurement. The DIC is also applied to measure an electrocardiogram-type signal and its QRS complex is well identified, which enables the estimation, for instance, of the heart rate.

13 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Rafael Gonzalez-LandaetaRafael Gonzalez-Landaeta
Rafael Gonzalez-Landaeta
BRBrenda Ramirez
Brenda Ramirez
JMJose Mejia
Jose Mejia
Cuffless blood pressure measurement enables unobtrusive and continuous monitoring that can be integrated with wearable devices to extend healthcare to non-hospital settings. Most of the current research has focused on the estimation of blood pressure based on pulse transit time or pulse arrival time using ECG or peripheral cardiac pulse signals as proximal time references. This study proposed the use of a phonocardiogram (PCG) and ballistocardiogram (BCG), two signals detected noninvasively, to estimate systolic blood pressure (SBP). For this, the PCG and the BCG were simultaneously measured in 21 volunteers in the rest, activity, and post-activity conditions. Different features were considered based on the relationships between these signals. The intervals between S1 and S2 of the PCG and the I, J, and K waves of the BCG were statistically analyzed. The IJ and JK slopes were also estimated as additional features to train the machine-learning algorithm. The intervals S1-J, S1-K, S1-I, J-S2, and I-S2 were negatively correlated with changes in SBP (p-val < 0.01). The features were used as explanatory variables for a regressor based on the Random Forest. It was possible to estimate the systolic blood pressure with a mean error of 3.3 mmHg with a standard deviation of ± 5 mmHg. Therefore, we foresee that this proposal has potential applications for wearable devices that use low-cost embedded systems.