Shi Yan

Dr. Shi Yan

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 July 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NQNan Qin
Nan Qin
MSMin Shen
Min Shen
PXPing Xiang
Ping Xiang
DWDi Wen
Di Wen
BSBaohua Shen
Baohua Shen
SYShi Yan
Shi Yan
The recent emergence of new fentanyl analogues and synthetic opioids on the drug market poses a global public health threat. However, these compounds cannot typically be identified using existing analytical methods. In this study, we aimed to develop and validate a rapid and sensitive method based on ultra-high-performance liquid chromatography–tandem mass spectrometry (UHPLC-MS/MS) for the simultaneous determination of 37 fentanyl analogues and novel synthetic opioids in hair samples. Hair samples (20 mg) were extracted by cryogenic grinding in an extraction medium of methanol, acetonitrile, and 2 mmol/L ammonium acetate (pH 5.3). Following centrifugation of the samples, the analytes were separated using a WATERS Acquity UPLC HSS T3 column. The limits of detection (LODs) and limits of quantification (LOQs) ranged from 0.5 to 2.5 pg/mg and from 2 to 5 pg/mg, respectively. The intraday and interday precisions were within 13.32% at LOQ, low, medium, and high levels. The accuracies were within the range of 85.63–116.1%. The extraction recoveries were in the range of 89.42–119.68%, and the matrix effects were within the range of 44.81–119.77%. Furthermore, the method was successfully applied to the detection and quantification of fentanyl and sufentanil in hair samples from two authentic cases. Thus, this method has great potential for detecting fentanyl analogues and novel synthetic opioids in forensic work.

1 August 2019 in Journal of Chromatography B
Verified
Journal Article
Closed access
NQNan Qin
Nan Qin
PXPing Xiang
Ping Xiang
BSBaohua Shen
Baohua Shen
XZXianyi Zhuo
Xianyi Zhuo
SYShi Yan
Shi Yan
FSFenyun Song
Fenyun Song

1 February 2022 in Forensic Science International
Verified
Journal Article
Closed access
ZLZhou Liying
Zhou Liying
SMShen Min
Shen Min
SBShen Baohua
Shen Baohua
CHChen Hang
Chen Hang
WXWang Xin
Wang Xin
SYShi Yan
Shi Yan

17 November 2020 in Journal of Analytical Toxicology
Verified
Journal Article
Closed access
YWYang Wang
Yang Wang
SYShi Yan
Shi Yan
YYYingjia Yu
Yingjia Yu
LCLizhu Chen
Lizhu Chen
JJJiebing Jiang
Jiebing Jiang
GDGengli Duan
Gengli Duan
After its use for decades in clinical screening, dried blood spots (DBS) have recently received considerable attention for their application in various novel psychoactive substances. The goal of this study was to develop and apply a DBS-based assay for 37 synthetic cathinones and their metabolites. Thirty microliters of whole blood sample after administration was spotted onto Whatman FTA classical cards, dried and extracted, and then analyzed by ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS-MS). The samples were chromatographed on a Waters Acquity UPLC®HSS T3 column (1.8 μm, 2.1 × 100 mm) and then identically packed defender guard cartridges of a Waters Acquity UPLC®HSS T3 column (1.8 μm, 2.1 × 5 mm, 3/pk). The separation was achieved via solvents of 20 mM ammonium acetate/formic acid 0.1% (A) and acetonitrile (B) at a flow rate of 0.25 mL/min. A tandem MS equipped with positive electrospray ionization mode source was used as the detector. Multiple reaction monitoring with the precursor/product ion combinations was used to quantify each analyte. The linear range of synthetic cathinones in the DBS was 2.0–200 ng/mL, and the lowest limit of quantification was 2.0 ng/mL for some synthetic cathinones and 10 ng/mL for others. The precision and accuracy of the results for the validation samples of the synthetic cathinones were within acceptable criteria. DBS sampling offers the advantages of reduced sample volume and convenient sample storage and shipment. This method can be successfully applied to the quantification of synthetic cathinones.

31 January 2025 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
GGGuoqing Gao
Guoqing Gao
SYShuo Yang
Shuo Yang
XWXin Wang
Xin Wang
PXPing Xiang
Ping Xiang
LMLiting Ma
Liting Ma
SYShi Yan
Shi Yan

28 September 2024 in Journal of Analytical Toxicology
Verified
Journal Article
Closed access
PDF file
ZLZhou Liying
Zhou Liying
ZJZhao Junbo
Zhao Junbo
XWXie Wanting
Xie Wanting
PXPING XIANG
PING XIANG
SYShi Yan
Shi Yan
YHYan Hui
Yan Hui
Recently, etomidate has been widely used as an alternative in illicit drug market. It is usually added to regular cigarette tobacco (commonly known as “cigarette powder”) or mixed in e-cigarette oil sold through the Internet, retail stores, or entertainment outlets and other channels. An ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed to quantify etomidate and etomidate acid in human blood and urine. The limit of detection (LOD) of etomidate and etomidate acid in blood are 0.5 ng/mL and 2 ng/mL, respectively, and the lower limit of quantification (LLOQ) are 1 ng/mL and 5 ng/mL, respectively. The LOD of etomidate and etomidate acid in urine are1 ng/mL and 2 ng/mL, respectively, and the LLOQ are 2 ng/mL and 5 ng/mL, respectively. The precision, accuracy, recoveries and matrix effects of etomidate and etomidate acid determinations in blood and urine met the requirements for methodological validation. The method was successfully applied to the identification and quantification of etomidate and etomidate acid in blood and urine of 62 forensic cases. The concentration of etomidate ranged from 1.52 to 8.41 ng/mL (positive cases, n=5) and the concentration of etomidate acid ranged from 2.76 to 112 ng/mL (positive cases, n=5) in blood. The concentrations of etomidate and etomidate acid in urine samples were 2.64-79,300 ng/mL (positive cases, n=59) and 6.11-518,000 ng/mL (positive cases, n=60), respectively. Therefore, the concentration of etomidate in blood and urine is mostly higher than that of etomidate.