Nurul Mutmainah Diah Oktaviani

Mrs. Nurul Mutmainah Diah Oktaviani

Food Science and Agricultural Product Technology, Universitas Gadjah Mada, Yogyakarta, Indonesia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2022 in Horticulturae
Verified
Journal Article
Open access
PDF file
ABAsadin Briliantama
Asadin Briliantama
Nurul Mutmainah Diah OktavianiNurul Mutmainah Diah Oktaviani
Nurul Mutmainah Diah Oktaviani
SRSitti Rahmawati
Sitti Rahmawati
Widiastuti SetyaningsihWidiastuti Setyaningsih
Widiastuti Setyaningsih
MPMiguel Palma
Miguel Palma
Nowadays, dried edible flowers have become one of the eating habits of a healthy lifestyle. The most common way to consume dried flowers is via infused water (tisane). A number of studies on dried edible flowers have reported antioxidant activities mainly due to their phenolic compounds. This work has developed a new extraction method using ultrasound technology to determine phenolic compounds in 15 widely consumed edible flowers. Several extraction factors including pulse duty cycle (0.2, 0.6, 1.0 s−1), temperature (10, 40, 70 °C), solvent-to-sample ratio (10:1, 20:1, 30:1 mL of solvent g −1 of sample), and solvent composition (0, 25, 50% methanol in water) have been optimized based on a Box–Behnken design coupled with response surface methodology. UPLC-PDA has been employed to quantify 12 major phenolic compounds (2,4,6-trihydroxy benzoic acid, protocatechuic acid, protocatechuic aldehyde, p-hydroxybenzoic acid, caffeic acid, vanillic acid, epicatechin, p-coumaric acid, ferulic acid, quercetin-3-rutinose, iso-ferulic acid, and quercetin-3-glucoside) in the extracts. The optimum extraction conditions for a 1 g sample were 30 mL of solvent (28% methanol in water) at 42 °C with 1.0 s−1 of pulse duty cycle. Based on the kinetic study, the optimal extraction time was 10 min. The method was validated with high precision (CVs of repeatability and intermediate precision were lower than 7%) and high accuracy (recovery higher than 90%). Additionally, the proposed ultrasound-assisted extraction was successfully applied in the determination of phenolic compounds in 15 dried edible flowers.

4 January 2023 in Foods
Verified
Journal Article
Open access
PDF file
Widiastuti SetyaningsihWidiastuti Setyaningsih
Widiastuti Setyaningsih
MBMaría del Cisne Guamán Balcázar
María del Cisne Guamán Balcázar
Nurul Mutmainah Diah OktavianiNurul Mutmainah Diah Oktaviani
Nurul Mutmainah Diah Oktaviani
MPMiguel Palma
Miguel Palma
A novel analytical method based on microwave-assisted extraction has been successfully optimized and validated to determine resveratrol from functional marmalade and cookies. The optimization was performed using a Box–Behnken design with three factors: solvent composition (60−100% and 10−70% methanol in water for marmalade and cookies, respectively), microwave power (250−750 W), and solvent-to-solid ratio (20:5−60:5). The main and quadratic effects of solvent composition significantly contributed to the recovery values (p < 0.005) for both kinds of samples. Additionally, the solvent-to-solid ratio and the quadratic effect of microwave power also influenced the resveratrol recovery from functional marmalade. Hence, the optimum condition for resveratrol extraction from marmalade (80% methanol, 500 W, solvent-to-solid ratio 40:5) and cookies (80% methanol, 250 W, solvent-to-solid ratio 20:5) was proposed. The extraction kinetics (5−30 min) was then studied to clarify the complete recovery of resveratrol from the food matrices resulting in 15 min as the optimum extraction time. The developed method showed a satisfactory precision indicated by the coefficient of variation (CV) lower than 5.70% for both repeatability and intermediate precision. To check the matrix effects, the developed MAE procedures were applied to a number of commercial marmalade and cookies. The high-fat and fiber cookies resulted in overestimated values due to the interfering ingredients. As a final point, the methods successfully measured the stability of naturally present resveratrol in grape-derived products while preparing functional marmalade and cookies.

10 July 2023 in Beverages
Verified
Journal Article
Open access
PDF file
ILIntan Dewi Larasati
Intan Dewi Larasati
Nurul Mutmainah Diah OktavianiNurul Mutmainah Diah Oktaviani
Nurul Mutmainah Diah Oktaviani
HLHanifah Nuryani Lioe
Hanifah Nuryani Lioe
TETeti Estiasih
Teti Estiasih
MPMiguel Palma
Miguel Palma
Widiastuti SetyaningsihWidiastuti Setyaningsih
Widiastuti Setyaningsih
Edible flowers, including roselle, contain a varied composition of phenolic compounds that may inhibit the oxidative stress mechanism. Roselle-based tisane with appealing sensory properties is commonly consumed worldwide. However, the conventional hot-brew method may ruin the stability of thermolabile phenolic compounds during the tisane preparation. Hence, this study aimed to develop a new alternative brewing method linked with the new cold-brew method, which involves a lower temperature and applying ultrasound to maximize the extraction of phenolic compounds and to avoid degradation during the tisane preparation. The brewing factors, including particle size (10, 20, 30 mesh), temperature (4, 15, 26 °C), time (10, 20, 30 min), and ultrasound amplitude (20, 60, 100% of the maximum amplitude) have been optimized simultaneously using Box–Behnken design in conjunction with response surface methodology. Seven major phenolic compounds were identified by HPLC-DAD and classified into hydroxycinnamic acid derivatives (HCA) and flavonoids. The optimum extraction condition to reach the highest level of the studied phenolic compounds was set to brew roselle with particle size of 30 ± 3.25 mesh at 26 ± 1.32 °C for 18 ± 2.00 min applying 78 ± 5.64% ultrasound amplitude. This method successfully extracted almost all HCA and flavonoid during the first cycle with less than 10% CV and provided higher antioxidant activity in terms of DPPH (IC50 9.77 ± 0.01 µg mL−1), ABTS (IC50 8.05 ± 0.02 µg mL−1), and FRAP (IC50 10.34 ± 0.03 µg mL−1) than the roselle tisane prepared using the conventional method. Additionally, the resulting cold-brew product was stable for up to five days of storage.

3 March 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
LSLaurencia Gabrielle Sutanto
Laurencia Gabrielle Sutanto
PJPrastika Krisma Jiwanti
Prastika Krisma Jiwanti
MSMirza A Saputra
Mirza A Saputra
MTMai Tomisaki
Mai Tomisaki
Nurul Mutmainah Diah OktavianiNurul Mutmainah Diah Oktaviani
Nurul Mutmainah Diah Oktaviani
QAQonita Kurnia Anjani
Qonita Kurnia Anjani
Ciprofloxacin (CIP) is an antibiotic that is widely used in humans and animals. However, the compound has been detected in animal-derived products and the environment due to its extensive use, causing serious concern for public health and environmental safety. The issue raises the urgent need to develop innovative techniques to monitor CIP. Therefore, this study aims to develop a simple and sensitive CIP sensor called the boron-doped diamond nanoparticle-modified screen-printed electrode (BDD NPs/SPE) and the nickel oxide nanoparticle-modified BDD NPs/SPE (NiO NPs/BDD NPs/SPE). NiO NPs were synthesized via green synthesis using Spatholobus littoralis Hassk. root extract as the reducing agent. The formation and characteristics of NiO NPs were then confirmed through a UV-Vis spectrophotometer, XRD, PSA, FT-IR, and XPS. The successful modification of SPE was confirmed through SEM-EDX, followed by measurements using square-wave voltammetry. The results showed that the modified SPE could detect CIP over a concentration range of 0.1–100 µM and produced a low detection limit of 0.109 µM for BDD NPs/SPE and 0.054 µM for NiO NPs/BDD NPs/SPE. The proposed method was successfully applied to the determination of CIP in commercial tablets, milk, and human urine, with a satisfactory % recovery from 95 to 100%. The current study successfully developed a simple yet highly sensitive sensor that enabled robust, reliable, and efficient detection of CIP, showing its strong potential for practical applications.