Field-oriented control and direct torque control are becoming the industrial standards for induction motors torque control. This paper is aimed at giving a contribution for a detailed comparison between the two control techniques, emphasizing advantages and disadvantages. The performance of the two control schemes is evaluated in terms of torque and current ripple, and transient response to step variations of the torque command. The analysis has been carried out on the basis of the results obtained by numerical simulations, where secondary effects introduced by hardware implementation are not present.
1 July 2000 in IEEE Transactions on Power Electronics
In this paper, a control scheme for multiphase induction motor drives is presented and assessed. This control scheme ensures the operation of a multiphase drive under an open-circuit phase fault that can occur in one or more phases at the same time. A fault-tolerant control strategy is developed. The mathematical analysis is based on the space vector representation of the multiphase system and is valid either in transient or steady-state operating conditions. The feasibility of the drive is verified by means of experimental tests carried out on a prototype of seven-phase induction motor.
5 June 2006 in IEEE Transactions on Energy Conversion
A maximum power point tracking algorithm for single-stage converters connecting photovoltaic (PV) panels to a single-phase grid is presented in this paper. The algorithm is based on the application of the "ripple correlation control" using as perturbation signals the current and voltage low-frequency oscillations introduced in the PV panels by the single-phase utility grid. The proposed control technique allows the generation of sinusoidal grid currents with unity power factor. The algorithm has been developed to allow an array of PV modules to be connected to the grid by using a single-stage converter. This simple structure yields higher efficiency and reliability when compared with standard solutions based on double-stage converter configurations. The proposed maximum power point tracking algorithm has been numerically simulated and experimentally verified by means of a converter prototype connected to a single-phase grid. The results are presented in the paper, showing the effectiveness of the proposed system.
1 September 2013 in IEEE Transactions on Industrial Electronics
A novel scheme for three-phase grid-connected photovoltaic (PV) generation systems is presented in this paper. The scheme is based on two insulated strings of PV panels, each one feeding the dc bus of a standard two-level three-phase voltage-source inverter (VSI). The inverters are connected to the grid by a three-phase transformer having open-end windings on the inverter side. The resulting conversion structure performs as a multilevel power active filter (equivalent to a three-level inverter), doubling the power capability of a single VSI with given voltage and current ratings. The multilevel voltage waveforms are generated by an improved space-vector-modulation algorithm, suitable for the implementation in industrial digital signal processors. An original control method has been introduced to regulate the dc-link voltages of each VSI, according to the voltage reference given by a single maximum power point tracking controller. The proposed regulation system has been verified by numerical simulations and experimental tests with reference to different operating conditions.