Electric vehicle (EV) is a promising technology for reducing environmental impacts of road transport. In this paper, a framework for optimal design of battery charging/swap stations in distribution systems based on life cycle cost (LCC) is presented. The battery charging/swap station models are developed to compare the impacts of rapid-charging stations and battery swap stations. Meanwhile, in order to meet the requirements of increased power provided during the charging period, the distribution network should be reinforced. In order to control this reinforcement cost, stations should be placed at appropriate places and be scaled correctly. For optimal cost-benefit analysis and safety operation, the LCC criterion is used to assess the project and a modified differential evolution algorithm is adopted to solve the problem. The proposed method has been verified on the modified IEEE 15-bus and 43-bus radial distribution systems. The results show that battery swap station is more suitable for public transportation in distribution systems.
20 January 2021 in IEEE Transactions on Smart Grid
The high penetration of intermittent renewable energy resources in active distribution networks (ADN) results in a great challenge for the conventional Volt-Var control (VVC). This article proposes a two-stage deep reinforcement learning (DRL)-based real-time VVC method to mitigate fast voltage violation while minimizing the network power loss. In the first stage, on-load tap changer (OLTC) and capacitor banks (CBs) are dispatched hourly based on the optimal power flow method. The optimization problem is formulated as a mixed-integer second-order cone programming (MISOCP) which can be effectively solved. In the second stage, the reactive power of photovoltaics (PVs) is regulated dynamically to mitigate fast voltage fluctuation based on the well-learned control strategy and local measurements. The real-time VVC problem is formulated and solved using a multi-agent deep deterministic policy gradient (MADDPG) method, which features offline centralized training and online decentralized application. Rather than using the critic network to evaluate the output of the actor-network, the gradient of the action-value function to action is derived analytically based on the voltage sensitivity method. The proposed approach is tested on the IEEE 33-bus distribution system and comparative simulation results show the enhanced control effect in mitigating voltage violations.
5 September 2013 in IEEE Transactions on Power Systems
Along with the increasing penetration of renewable energy, distribution system power flow may be significantly altered in terms of direction and magnitude. This will make delivering reliable power, on demand, a major challenge. In this paper, a novel battery energy storage system (BESS) based energy acquisition model is proposed for the operation of distribution companies (DISCOs) in regulating price or locational marginal price (LMP) mechanisms, while considering energy provision options within DISCO controlled areas. Based on this new model, a new battery operation strategy is proposed for better utilization of energy storage system (ESS) and mitigation operational risk from price volatility. Meanwhile, optimal sizing and siting decisions for BESS is obtained through a cost-benefit analysis method, which aims at maximizing the DISCO's profit from energy transactions, system planning and operation cost savings. The proposed energy acquisition model and ESS control strategy are verified on a modified IEEE 15-bus distribution network, and risk mitigation is also quantified in two different markets. The promising results show that the capacity requirement for ESS can be reduced and the operational risk can also be mitigated.
14 January 2020 in IEEE Transactions on Power Systems
Regarding the continuing increase of anthropogenic carbon emissions in the power system with growing energy consumption, researchers have focused on managing the demand side to achieve low-carbon transition. However, such a low-carbon transition cannot be achieved effectively without the proper incentive scheme. Moreover, it is desired to improve the computation quality of carbon tracing tools and extend their applications by state-of-art techniques. To fulfil these existing research gaps, this paper proposes a low-carbon optimal scheduling model with demand response (DR) based carbon intensity control. It aims to reduce the dependence of customers on energy sources with high carbon intensities while decreasing reasonable energy consumption. Likewise, a data-driven approach conducted with the Bayesian interfere regression is proposed to carry out the carbon emission flow (CEF) model to cope with the drawbacks of the conventional emission calculation. Moreover, the storage emission and relevant dynamic impacts to the system are fully considered. The proposed data-driven approach is tested on a series of IEEE systems with different sizes, its high accuracy and efficiency are proved by the simulation results. Further, simulation results indicate that the proposed scheduling model can effectively achieve carbon emission mitigation.