Bevin Gangadharan

Dr. Bevin Gangadharan

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2007 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
BGBevin Gangadharan
Bevin Gangadharan
RARobin Antrobus
Robin Antrobus
RDRaymond A Dwek
Raymond A Dwek
NZNicole Zitzmann
Nicole Zitzmann
Background: Liver biopsy is currently the gold standard for assessing liver fibrosis, and no reliable noninvasive diagnostic approach is available. Therefore a suitable serologic biomarker of liver fibrosis is urgently needed.Methods: We used a proteomics method based on 2-dimensional gel electrophoresis to identify potential fibrosis biomarkers. Serum samples from patients with varying degrees of hepatic scarring induced by infection with the hepatitis C virus (HCV) were analyzed and compared with serum from healthy controls.Results: We observed the most prominent differences when we compared serum samples from cirrhotic patients with healthy control serum. Inter-α-trypsin inhibitor heavy chain H4 (ITIH4) fragments, α1 antichymotrypsin, apolipoprotein L1 (Apo L1), prealbumin, albumin, paraoxonase/arylesterase 1, and zinc-α2-glycoprotein were decreased in cirrhotic serum, whereas CD5 antigen-like protein (CD5L) and β2 glycoprotein I (β2GPI) were increased. In general, α2 macroglobulin (a2M) and immunoglobulin components increased with hepatic fibrosis, whereas haptoglobin and complement components (C3, C4, and factor H-related protein 1) decreased. Novel proteins associated with HCV-induced fibrosis included ITIH4 fragments, complement factor H-related protein 1, CD5L, Apo L1, β2GPI, and thioester-cleaved products of a2M.Conclusions: Assessment of hepatic scarring may be performed with a combination of these novel fibrosis biomarkers, thus eliminating the need for liver biopsy. Further evaluation of these candidate markers needs to be performed in larger patient populations. Diagnosis of fibrosis during early stages will allow early treatment, thereby preventing fibrosis progression.

31 March 2021 in ACS Central Science
Verified
Journal Article
Open access
JBJuliane Brun
Juliane Brun
SVSnežana Vasiljevic
Snežana Vasiljevic
BGBevin Gangadharan
Bevin Gangadharan
MHMario Hensen
Mario Hensen
ACAnu V. Chandran
Anu V. Chandran
NZNicole Zitzmann
Nicole Zitzmann
Severe acute respiratory syndrome coronavirus 2 is the causative pathogen of the COVID-19 pandemic which as of March 29, 2021, has claimed 2 776 175 lives worldwide. Vaccine development efforts focus on the viral trimeric spike glycoprotein as the main target of the humoral immune response. Viral spikes carry glycans that facilitate immune evasion by shielding specific protein epitopes from antibody neutralization, and antigen efficacy is influenced by spike glycoprotein production in vivo. Therefore, immunogen integrity is important for glycoprotein-based vaccine candidates. Here, we show how site-specific glycosylation differs between virus-derived spikes, spike proteins derived from a construct similar to a SARS-CoV-2 vaccine candidate, and commonly used recombinant, engineered spike glycoproteins. Furthermore, we show that their distinctive cellular secretion pathways result in different protein glycosylation and secretion patterns, including shedding of spike monomeric subunits for the vaccine candidate tested, which may have implications for the resulting immune response and vaccine design.

26 June 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BGBevin Gangadharan
Bevin Gangadharan
MBManisha Bapat
Manisha Bapat
JRJan Rossa
Jan Rossa
RARobin Antrobus
Robin Antrobus
DCDavid Chittenden
David Chittenden
NZNicole Zitzmann
Nicole Zitzmann
Liver biopsy is the reference standard for assessing liver fibrosis and no reliable non-invasive diagnostic approach is available to discriminate between the intermediate stages of fibrosis. Therefore suitable serological biomarkers of liver fibrosis are urgently needed. We used proteomics to identify novel fibrosis biomarkers in hepatitis C patients with different degrees of liver fibrosis. Proteins in plasma samples from healthy control individuals and patients with hepatitis C virus (HCV) induced cirrhosis were analysed using a proteomics technique: two dimensional gel electrophoresis (2-DE). This technique separated the proteins in plasma samples of control and cirrhotic patients and by visualizing the separated proteins we were able to identify proteins which were increasing or decreasing in hepatic cirrhosis. Identified markers were validated across all Ishak fibrosis stages and compared to the markers used in FibroTest, Enhanced Liver Fibrosis (ELF) test, Hepascore and FIBROSpect by Western blotting. Forty four candidate biomarkers for hepatic fibrosis were identified of which 20 were novel biomarkers of liver fibrosis. Western blot validation of all candidate markers using plasma samples from patients across all Ishak fibrosis scores showed that the markers which changed with increasing fibrosis most consistently included lipid transfer inhibitor protein, complement C3d, corticosteroid-binding globulin, apolipoprotein J and apolipoprotein L1. These five novel fibrosis markers which are secreted in blood showed a promising consistent change with increasing fibrosis stage when compared to the markers used for the FibroTest, ELF test, Hepascore and FIBROSpect. These markers will be further validated using a large clinical cohort. This study identifies 20 novel fibrosis biomarker candidates. The proteins identified may help to assess hepatic fibrosis and eliminate the need for invasive liver biopsies.

19 October 2023 in Vaccine
Verified
Journal Article
Open access
SMSARA MOSCA
SARA MOSCA
QLQianqi Lin
Qianqi Lin
RSRobert Stokes
Robert Stokes
TBTehmina Bharucha
Tehmina Bharucha
BGBevin Gangadharan
Bevin Gangadharan
NSNicholas Stone
Nicholas Stone
Preventing, detecting, and responding to substandard and falsified vaccines is of critical importance for ensuring the safety, efficacy, and public trust in vaccines. This is of heightened importance in context of public health crisis, such as the COVID-19 pandemic, in which extreme world-wide shortages of vaccines provided a fertile ground for exploitation by falsifiers. Here, a proof-of-concept study explored the feasibility of using a handheld Spatially Offset Raman Spectroscopy (SORS) device to authenticate COVID-19 vaccines through rapid analysis of unopened vaccine vials. The results show that SORS can verify the chemical identity of dominant excipients non-invasively through vaccine vial walls. The ability of SORS to identify potentially falsified COVID-19 vaccines was demonstrated by measurement of surrogates for falsified vaccines contained in vaccine vials. In all cases studied, the SORS technique was able to differentiate between surrogate samples from the genuine COVISHIELD™ vaccine. The genuine vaccines tested included samples from six batches across two manufacturing sites to account for any potential variations between batches or manufacturing sites. Batch and manufacturing site variations were insignificant. In conjunction with existing security features, for example on labels and packaging, SORS provided an intrinsic molecular fingerprint of the dominant excipients of the vaccines. The technique could be extended to other COVID-19 and non-COVID-19 vaccines, as well as other liquid medicines. As handheld and portable SORS devices are commercially available and widely used for other purposes, such as airport security, they are rapidly deployable non-invasive screening tools for vaccine authentication.

30 March 2011 in Journal of Proteome Research
Verified
Journal Article
Open access
BGBevin Gangadharan
Bevin Gangadharan
RARobin Antrobus
Robin Antrobus
DCDavid Chittenden
David Chittenden
JRJan Rossa
Jan Rossa
MBManisha Bapat
Manisha Bapat
NZNicole Zitzmann
Nicole Zitzmann
Despite many shortcomings, liver biopsy is regarded as the gold standard for assessing liver fibrosis. A less invasive and equally or more reliable approach would constitute a major advancement in the field. Proteomics can aid discovery of novel serological markers and these proteins can be measured in patient blood. A major challenge of discovering biomarkers in serum is the presence of highly abundant serum proteins, which restricts the levels of total protein loaded onto gels and limits the detection of low abundance features. To overcome this problem, we used two-dimensional gel electrophoresis (2-DE) over a narrow pH 3−5.6 range since this lies outside the range of highly abundant albumin, transferrin and immunoglobulins. In addition, we used in-solution isoelectric focusing followed by SDS-PAGE to find biomarkers in hepatitis C induced liver cirrhosis. Using the pH 3−5.6 range for 2-DE, we achieved improved representation of low abundance features and enhanced separation. We found in-solution isoelectric focusing to be beneficial for analyzing basic, high molecular weight proteins. Using this method, the beta chains of both complement C3 and C4 were found to decrease in serum from hepatitis C patients with cirrhosis, a change not observed previously by 2-DE. We present two proteomics approaches that can aid in the discovery of clinical biomarkers in various diseases and discuss how these approaches have helped to identify 23 novel biomarkers for hepatic fibrosis.

23 May 2023 in Journal of Proteome Research
Verified
Journal Article
Open access
TBTehmina Bharucha
Tehmina Bharucha
BGBevin Gangadharan
Bevin Gangadharan
AKAbhinav Kumar
Abhinav Kumar
AMAshleigh C. Myall
Ashleigh C. Myall
NANazli Ayhan
Nazli Ayhan
SCSEAe Consortium
SEAe Consortium
Japanese encephalitis virus is a leading cause of neurological infection in the Asia-Pacific region with no means of detection in more remote areas. We aimed to test the hypothesis of a Japanese encephalitis (JE) protein signature in human cerebrospinal fluid (CSF) that could be harnessed in a rapid diagnostic test (RDT), contribute to understanding the host response and predict outcome during infection. Liquid chromatography and tandem mass spectrometry (LC-MS/MS), using extensive offline fractionation and tandem mass tag labeling (TMT), enabled comparison of the deep CSF proteome in JE vs other confirmed neurological infections (non-JE). Verification was performed using data-independent acquisition (DIA) LC-MS/MS. 5,070 proteins were identified, including 4,805 human proteins and 265 pathogen proteins. Feature selection and predictive modeling using TMT analysis of 147 patient samples enabled the development of a nine-protein JE diagnostic signature. This was tested using DIA analysis of an independent group of 16 patient samples, demonstrating 82% accuracy. Ultimately, validation in a larger group of patients and different locations could help refine the list to 2-3 proteins for an RDT. The mass spectrometry proteomics data have been deposited to the ProteomeXchange Consortium via the PRIDE partner repository with the dataset identifier PXD034789 and 10.6019/PXD034789.