JUN CHEN

Dr. JUN CHEN

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
JCJiangyu Cai
Jiangyu Cai
JWJuan Wang
Juan Wang
KYKaiqiang Ye
Kaiqiang Ye
DLDandan Li
Dandan Li
CAChengchong Ai
Chengchong Ai
SCShiyi Chen
Shiyi Chen
Background: Tendon/ligament injuries are common sports injuries. Clinically, the repair of a ruptured tendon or ligament to its bony insertion is needed, but the enthesis structure is not well reestablished following surgical repair. Herein, we fabricated dual-layer aligned-random scaffold (ARS) by electrospinning and aimed to investigate the effect of the scaffold on tendon-to-bone healing in vivo. Materials and methods: The random and dual-layer aligned-random silk fbroin poly(L-lactic acid-co-e-caprolactone) (P(LLA-CL)) nanofibrous scaffolds were successfully fabricated by electrospinning methods. Ninety New Zealand white rabbits were randomly divided into three groups (random scaffold [RS], ARS, and control groups), and they were subjected to surgery to establish an extra-articular tendon-to-bone healing model with autologous Achilles tendon. Results: Histological assessment showed that the ARS significantly increased the area of metachromasia, decreased the interface width, and improved collagen maturation and organization at the tendon–bone interface compared with the RS and control groups. Microcomputed tomography analysis showed that the bone tunnel area of RS and ARS groups was significantly smaller than those of the control group. Real-time polymerase chain reaction showed that BMP-2 and osteopontin expression levels of the tissue at the interface between the bone and graft in the RS and ARS groups were higher than those of the control group at 6 weeks. Collagen I expression level of the ARS group was significantly higher than those of the RS and control groups at 6 and 12 weeks. Moreover, the ARS groups had a better ultimate load-to-failure and stiffness than the RS and control groups. Conclusion: ARS could effectively augment the tendon-to-bone integration and improve gradient microstructure in a rabbit extra-articular model by inducing the new bone formation, increasing the area of fibrocartilage, and improving collagen organization and maturation. The dual-layer aligned-random silk fibroin/P(LLA-CL) nanofibrous scaffold is proved to be a promising biomaterial for tendon-to-bone healing.

28 June 2019 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
DSDandan Sheng
Dandan Sheng
JLJinxiu Li
Jinxiu Li
CAChengchong Ai
Chengchong Ai
SFSijia Feng
Sijia Feng
TYTing Ying
Ting Ying
SCShiyi Chen
Shiyi Chen
Tendons can transmit mechanical force from muscles to bones for movement. However, the mechanical strength of tendons is compromised after surgery, thus causing a high rate of tendon retear. Hence, the design and preparation of biodegradable materials with excellent mechanical properties have become an urgent demand for sports medicine. In this study, biomimetic polycaprolactone (PCL)/gelatin (Gel)-aligned scaffolds were fabricated for the mechanical restoration of the injured tendon in a rabbit model. The diameter of nanofibers was about 427.82 ± 56.99 nm, which was approximate to that of the native collagen fibrils; the directional consistency of the nanofibers in PCL/Gel-aligned scaffolds reached 77.33 ± 3.22%, which were ultrastructurally biomimetic. Compared to the observations for the control group, the in vitro mechanical results showed that the PCL/Gel-aligned scaffolds (P/G-A) were anisotropic in terms of failure load, tensile strength, and Young's modulus. After verifying their good cytocompatibility, the scaffolds were implanted into the rabbit patellar tendon in situ. The biomechanical properties of the repaired tendon in P/G-A reached 343.97 ± 65.30 N in failure load, 85.99 ± 16.33 MPa in tensile strength, 590.84 ± 201.87 MPa in Young's modulus, and 171.29 ± 61.50 N mm−1 in stiffness in vivo at 8 weeks post operation. In a word, our results demonstrated that P/G-A could support the regenerated tissue of injured patellar tendons to restore the biomechanical strength in a rabbit model. This suggested that the PCL/Gel-aligned scaffolds can pave a promising way to improve the healing of injured tendons in the clinic in the future.

13 August 2020 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
XZXingyu Zhang
Xingyu Zhang
JCJUN CHEN
JUN CHEN
QJQin Jiang
Qin Jiang
XDXiaoquan Ding
Xiaoquan Ding
YLYunxia Li
Yunxia Li
SCShiyi Chen
Shiyi Chen
Cartilage injury is very common and results in considerable pain and osteoarthritis. Owing to its low self-renewal capability, cartilage regeneration is still a great challenge for clinicians. Stem cell therapy has been treated as the most promising treatment for cartilage regeneration in recent decades. However, increasing concerns about the potential biosafety of stem cell products such as immune rejection and neoplastic transformation restrict their further application in clinic. Herein, biomimetic stem cell membrane-disguised nanovehicles without biosafety risks are designed and prepared for cartilage regeneration. In this study, based on the disguise of the natural bone marrow mesenchymal stem cell (BMSC) membrane, Kartogenin (KGN) as a drug for cartilage regeneration was encapsulated into Fe3O4 nanoparticles as the core of biomimetic stem cell nanovehicles. In the core–shell structure of biomimetic stem cell nanovehicles, the fabricated KGN-loaded BMSC membrane-disguised Fe3O4 nanoparticles (KGN-MNPs) showed a stable hybrid structure with a uniform size and morphology in the physiological environments. Moreover, the prepared KGN-MNPs exhibited excellent biocompatibility when disguised with the natural membrane of BMSCs and good biosafety by eliminating the nuclei of BMSCs. In a cartilage defect rat model, compared with pure KGN, the intra-articularly injected KGN-MNPs were capable of regenerating an integrated organized structure with a layer of hyaline-like cartilage in a shorter time due to the retained natural activities of the BMSC membrane. In a word, KGN-MNPs as one kind of our designed biomimetic stem cell nanovehicles enable rapid and high quality cartilage regeneration, and provide a novel and standardized strategy for stem cell therapy in the future.

15 September 2022 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
SPShu-Chen Pei
Shu-Chen Pei
CLChao-Zheng Li
Chao-Zheng Li
XPXin-Yu Pei
Xin-Yu Pei
WZWen-Hong Zeng
Wen-Hong Zeng
YZYuan-Yuan Zhang
Yuan-Yuan Zhang
JCJun Chen
Jun Chen

1 June 2018 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
SWSiheng Wang
Siheng Wang
YGYunshen Ge
Yunshen Ge
CAChengchong Ai
Chengchong Ai
JJJia Jiang
Jia Jiang
JCJiangyu Cai
Jiangyu Cai
SCShiyi Chen
Shiyi Chen
Purpose: This study was designed to evaluate the biocompatibility and osseointegration of polyethylene terephthalate ligament after coating with hydroxyapatite (PET/HA) by using the plasma spraying technique in vitro and in vivo. Methods: In this study, PET/HA sheets were prepared by using the plasma spraying technique. The characterization, the viability of bone marrow stromal cells (BMSCs), and the mRNA expression of bone formation-related genes were evaluated in vitro. The osseointegration in vivo was investigated in the rabbit anterior cruciate ligament (ACL) reconstruction model by micro-computed tomography (micro-CT) analysis, histological evaluation, and biomechanical tests. Results: Scanning electron microscopy (SEM) results showed that the surface of polyethylene terephthalate (PET) becomes rough after spraying with hydroxyapatite (HA) nanoparticles, and the water contact angle was 75.4°±10.4° in the PET/HA-plasma group compared to 105.3°±10.9° in the control group (p<0.05). The cell counting kit-8 counting results showed that the number of BMSCs significantly increased in the PET/HA-plasma group (p<0.05). Reverse transcription polymerase chain reaction (RT-PCR) results showed that there was an upregulated mRNA expression of bone formation-related genes in the PET/HA-plasma group (p<0.05). Micro-CT results showed that the transactional area of tibial tunnels and femoral tunnels was smaller in the PET/HA-plasma group (p<0.05). The histological evaluation scores of the PET/HA-plasma group were significantly superior to those of the PET control group at 8 and 12 weeks (p<0.05). The biomechanical tests showed an increased maximum load to failure and stiffness in the PET/HA-plasma group compared to those in the control group at 8 and 12 weeks. Conclusion: Both in vitro and in vivo results demonstrated in this study suggest that the biocompatibility and osseointegration of PET/HA ligament were significantly improved by increasing the proliferation of cells and upregulating the expression of bone formation-related genes. In a word, the PET/HA-plasma ligament is a promising candidate for ACL reconstruction in future.

1 August 2019 in Advanced Science
Verified
Journal Article
Open access
PDF file
YYYimeng Yang
Yimeng Yang
JCJUN CHEN
JUN CHEN
XSXiliang Shang
Xiliang Shang
ZFZhujun Feng
Zhujun Feng
CCChen Chen
Chen Chen
SCShiyi Chen
Shiyi Chen
Mesenchymal stem cells (MSCs) are capable of exerting strong therapeutic potential for the treatment of supraspinatus tendon tear. However, MSC therapy remains underutilized and perhaps underrated due to the limited evidence of dynamic visualization of cellular behavior in vivo. Here, second near‐infrared fluorescence imaging with biocompatible PbS quantum dots (QDs) provides a cellular migration map and information on the biodistribution and clearance processes of three densities of intra‐articularly injected, labeled MSCs to treat supraspinatus tendon tear in mice. Intra‐articular injection avoids entrapment of MSCs by filter organs and reduces the QD‐induced organ toxicity. Notably, the MSCs share a similar migration direction, but the moderate density group is somewhat more efficient, showing the longest residence time and highest cell retention rate around the footprint during the repair stage. Furthermore, quantitative kinetic investigation demonstrates that labeled MSCs are cleared by feces and urine. Histomorphometric analysis demonstrates that the moderate density group achieves maximum therapeutic effect and labeled MSCs do not induce any injury or inflammation to major organs, which suggests that administration of too many or few MSCs may decrease their effectiveness. Such an imaging approach provides spatiotemporal evidence for response to MSC therapy in vivo, facilitating the optimization of MSC therapy.