Joel Bixler

Dr. Joel Bixler

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JBJoel Bixler
Joel Bixler
BHBrett H. Hokr
Brett H. Hokr
MDMichael L Denton
Michael L Denton
GNGary D. Noojin
Gary D. Noojin
ASAurora D. Shingledecker
Aurora D. Shingledecker
VYVladislav Yakovlev
Vladislav Yakovlev
The time-temperature effects of laser radiation exposure are investigated as a function of wavelength. Here, we report the thermal response of bulk tissue as a function of wavelength from 700 to 1064 nm. Additionally, Monte Carlo simulations were used to verify the thermal response measured and predict damage thresholds based on the response.

8 November 2022 in Bioelectrochemistry
Verified
Journal Article
Closed access
VKVitalii Kim
Vitalii Kim
ISIurii Semenov
Iurii Semenov
AKAllen S. Kiester
Allen S. Kiester
MKMark A. Keppler
Mark A. Keppler
BIBennett L. Ibey
Bennett L. Ibey
Andrei PakhomovAndrei Pakhomov
Andrei Pakhomov

1 December 2021 in Bioelectrochemistry
Verified
Journal Article
Open access
AKAllen S. Kiester
Allen S. Kiester
BIBennett L. Ibey
Bennett L. Ibey
ZCZachary N. Coker
Zachary N. Coker
APAndrei G. Pakhomov
Andrei G. Pakhomov
JBJoel Bixler
Joel Bixler
The ability to directly observe membrane potential charging dynamics across a full microscopic field of view is vital for understanding interactions between a biological system and a given electrical stimulus. Accurate empirical knowledge of cell membrane electrodynamics will enable validation of fundamental hypotheses posited by the single shell model, which includes the degree of voltage change across a membrane and cellular sensitivity to external electric field non-uniformity and directionality. To this end, we have developed a high-speed strobe microscopy system with a time resolution of ~ 6 ns that allows us to acquire time-sequential data for temporally repeatable events (non-injurious electrostimulation). The imagery from this system allows for direct comparison of membrane voltage change to both computationally simulated external electric fields and time-dependent membrane charging models. Acquisition of a full microscope field of view enables the selection of data from multiple cell locations experiencing different electrical fields in a single image sequence for analysis. Using this system, more realistic membrane parameters can be estimated from living cells to better inform predictive models. As a proof of concept, we present evidence that within the range of membrane conductivity used in simulation literature, higher values are likely more valid.

Verified
Journal Article
Open access
PDF file
EGEmily Gudvangen
Emily Gudvangen
UMUma Maheswari Mangalanathan
Uma Maheswari Mangalanathan
ISIurii Semenov
Iurii Semenov
AKAllen S. Kiester
Allen S. Kiester
MKMark A. Keppler
Mark A. Keppler
Andrei PakhomovAndrei Pakhomov
Andrei Pakhomov
Cancer ablation therapies aim to be efficient while minimizing damage to healthy tissues. Nanosecond pulsed electric field (nsPEF) is a promising ablation modality because of its selectivity against certain cell types and reduced neuromuscular effects. We compared cell killing efficiency by PEF (100 pulses, 200 ns–10 µs duration, 10 Hz) in a panel of human esophageal cells (normal and pre-malignant epithelial and smooth muscle). Normal epithelial cells were less sensitive than the pre-malignant ones to unipolar PEF (15–20% higher LD50, p < 0.05). Smooth muscle cells (SMC) oriented randomly in the electric field were more sensitive, with 30–40% lower LD50 (p < 0.01). Trains of ten, 300-ns pulses at 10 kV/cm caused twofold weaker electroporative uptake of YO-PRO-1 dye in normal epithelial cells than in either pre-malignant cells or in SMC oriented perpendicularly to the field. Aligning SMC with the field reduced the dye uptake fourfold, along with a twofold reduction in Ca2+ transients. A 300-ns pulse induced a twofold smaller transmembrane potential in cells aligned with the field, making them less vulnerable to electroporation. We infer that damage to SMC from nsPEF ablation of esophageal malignancies can be minimized by applying the electric field parallel to the predominant SMC orientation.

26 August 2022 in Photonics Research
Verified
Journal Article
Closed access
MKMark A. Keppler
Mark A. Keppler
ZSZachary A. Steelman
Zachary A. Steelman
ZCZachary N. Coker
Zachary N. Coker
MNMiloš Nesládek
Miloš Nesládek
PHPhilip R. Hemmer
Philip R. Hemmer
JBJoel Bixler
Joel Bixler
Nitrogen vacancy diamonds have emerged as sensitive solid-state magnetic field sensors capable of producing diffraction limited and sub-diffraction field images. Here, for the first time, to our knowledge, we extend those measurements to high-speed imaging, which can be readily applied to analyze currents and magnetic field dynamics in circuits on a microscopic scale. To overcome detector acquisition rate limitations, we designed an optical streaking nitrogen vacancy microscope to acquire two-dimensional spatiotemporal kymograms. We demonstrate magnetic field wave imaging with micro-scale spatial extent and ∼ 400    μs temporal resolution. In validating this system, we detected magnetic fields down to 10 μT for 40 Hz magnetic fields using single-shot imaging and captured the spatial transit of an electromagnetic needle at streak rates as high as 110 μm/ms. This design has the capability to be readily extended to full 3D video acquisition by utilizing compressed sensing techniques and a potential for further improvement of spatial resolution, acquisition speed, and sensitivity. The device opens opportunities to many potential applications where transient magnetic events can be isolated to a single spatial axis, such as acquiring spatially propagating action potentials for brain imaging and remotely interrogating integrated circuits.

4 April 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
ZSZachary A. Steelman
Zachary A. Steelman
SMStacey Martens
Stacey Martens
JTJennifer Tran
Jennifer Tran
ZCZachary N. Coker
Zachary N. Coker
ASAnna Sedelnikova
Anna Sedelnikova
JBJoel Bixler
Joel Bixler
Quantitative measurements of water content within a single cell are notoriously difficult. In this work, we introduce a single-shot optical method for tracking the intracellular water content, by mass and volume, of a single cell at video rate. We utilize quantitative phase imaging and a priori knowledge of a spherical cellular geometry, leveraging a two-component mixture model to compute the intracellular water content. We apply this technique to study CHO-K1 cells responding to a pulsed electric field, which induces membrane permeabilization and rapid water influx or efflux depending upon the osmotic environment. The effects of mercury and gadolinium on water uptake in Jurkat cells following electropermeabilization are also examined.