Roisin Holmes

Ms. Roisin Holmes


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2017 in Polymers
Verified
Journal Article
Open access
PDF file
RHRoisin Holmes
Roisin Holmes
Xuebin  YangXuebin Yang
Xuebin Yang
ADAishling Dunne
Aishling Dunne
LFLarisa Florea
Larisa Florea
DWDavid Wood
David Wood
Giuseppe TronciGiuseppe Tronci
Giuseppe Tronci
Thiol-ene photo-click hydrogels were prepared via step-growth polymerisation using thiol-functionalised type-I collagen and 8-arm poly(ethylene glycol) norbornene-terminated (PEG-NB), as a potential injectable regenerative device. Type-I collagen was thiol-functionalised by a ring opening reaction with 2-iminothiolane (2IT), whereby up to 80 Abs.% functionalisation and 90 RPN% triple helical preservation were recorded via 2,4,6-Trinitrobenzenesulfonic acid (TNBS) colorimetric assay and circular dichroism (CD). Type, i.e., either 2-Hydroxy-1-[4-(2-hydroxyethoxy) phenyl]-2-methyl-1-propanone (I2959) or lithium phenyl-2,4,6-trimethylbenzoylphosphinate (LAP), and concentration of photoinitiator were varied to ensure minimal photoinitiator-induced cytotoxicity and to enable thiol-ene network formation of collagen-PEG mixtures. The viability of G292 cells following 24 h culture in photoinitiator-supplemented media was largely affected by the photoinitiator concentration, with I2959-supplemented media observed to induce higher toxic response (0.1 → 0.5% (w/v) I2959, cell survival: 62 → 2 Abs.%) compared to LAP-supplemented media (cell survival: 86 → 8 Abs.%). In line with the in vitro study, selected photoinitiator concentrations were used to prepare thiol-ene photo-click hydrogels. Gelation kinetics proved to be largely affected by the specific photoinitiator, with LAP-containing thiol-ene mixtures leading to significantly reduced complete gelation time (τ: 187 s) with respect to I2959-containing mixtures (τ: 1683 s). Other than the specific photoinitiator, the photoinitiator concentration was key to adjusting the hydrogel storage modulus (G’), whereby 15-fold G’ increase (232 → 3360 Pa) was observed in samples prepared with 0.5% (w/v) compared to 0.1% (w/v) LAP. Further thiol-ene formulations with 0.5% (w/v) LAP and varied content of PEG-NB were tested to prepare photo-click hydrogels with porous architecture, as well as tunable storage modulus (G’: 540–4810 Pa), gelation time (τ: 73–300 s) and swelling ratio (SR: 1530–2840 wt %). The photoinitiator-gelation-cytotoxicity relationships established in this study will be instrumental to the design of orthogonal collagen-based niches for regenerative medicine.

1 August 2017 in Materials Science and Engineering: C
Verified
Journal Article
Open access
RHRoisin Holmes
Roisin Holmes
SKSteve Kirk
Steve Kirk
Giuseppe TronciGiuseppe Tronci
Giuseppe Tronci
Xuebin  YangXuebin Yang
Xuebin Yang
DWDavid Wood
David Wood
Currently two factors hinder the use of collagen as building block of regenerative devices: the limited mechanical strength in aqueous environment, and potential antigenicity. Polymeric collagen is naturally found in the cross-linked state and is mechanically tougher than the monomeric, acid-soluble collagen ex vivo. The antigenicity of collagen, on the other hand, is mainly ascribed to inter-species variations in amino acid sequences of the non-helical terminal telopeptides. These telopeptides can be removed through enzymatic treatment to produce atelocollagen, although the effect of this cleavage on triple helix organization, amino acidic composition and thermal properties is often disregarded. Here, we compare the structural, chemical and physical properties of polymeric and monomeric type I collagen with and without telopeptides, in an effort to elucidate the influence of either mature covalent crosslinks or telopeptides. Circular dichroism (CD) was used to examine the triple helical conformation and quantify the denaturation temperature (Td) of both monomeric collagen (36.5°C) and monomeric atelocollagen (35.5°C). CD measurements were combined with differential scanning calorimetry (DSC) in order to gain insight into the triple helix-to-coil thermal transition and shrinkage temperature (Ts) of polymeric atelo collagen (44.8°C), polymeric collagen (62.7°C), monomeric atelo collagen (51.4°C) and monomeric collagen (66.5°C). Structural and thermal analysis was combined with high pressure liquid chromatography (HPLC) to determine the content of specific collagen amino acidic residues used as markers for the presence of telopeptides and mature crosslinks. Hydroxylamine was used as the marker for polymeric collagen, and had a total content of 9.66% for both polymeric and polymeric atelo collagen; tyrosine was used as the marker for telopeptide cleavage, was expressed as 0.526% of the content of polymeric collagen and the partially-reduced content of 0.39% for atelocollagen.

18 October 2016 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
Giuseppe TronciGiuseppe Tronci
Giuseppe Tronci
JYJie Yin
Jie Yin
RHRoisin Holmes
Roisin Holmes
HLHe Liang
He Liang
SRStephen J. Russell
Stephen J. Russell
DWDavid J. Wood
David J. Wood
The design of exudate-managing wound dressings is an established route to accelerated healing, although such design remains a challenge from material and manufacturing standpoints. Aiming towards the clinical translation of knowledge gained in vitro with highly-swollen rat tail collagen hydrogels, this study investigated the healing capability in a diabetic mouse wound model of telopeptide-free, protease-inhibiting collagen networks. 4-Vinylbenzylation and UV irradiation of type I atelocollagen (AC) led to hydrogel networks with chemical and macroscopic properties comparable to previous collagen analogues, attributable to similar lysine content and dichroic properties. After 4 days in vitro, hydrogels induced nearly 50 RFU% reduction in matrix metalloproteinase (MMP)-9 activity, whilst showing less than 20 wt% mass loss. After 20 days in vivo, dry networks promoted 99% closure of 10 × 10 mm full thickness wounds and accelerated neo-dermal tissue formation compared to Mepilex®. This collagen system can be equipped with multiple, customisable properties and functions key to personalised chronic wound care.