Sally Mahmoud

Dr. Sally Mahmoud

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
NKNawal Ahmed Al Kaabi
Nawal Ahmed Al Kaabi
YYYun Kai Yang
Yun Kai Yang
LDLi Fang Du
Li Fang Du
KXKe Xu
Ke Xu
SSShuai Shao
Shuai Shao
QLQi Ming Li
Qi Ming Li
NVSI-06-08 is a potential broad-spectrum recombinant COVID-19 vaccine that integrates the antigens from multiple SARS-CoV-2 strains into a single immunogen. Here, we evaluate the safety and immunogenicity of NVSI-06-08 as a heterologous booster dose in BBIBP-CorV recipients in a randomized, double-blind, controlled, phase 2 trial conducted in the United Arab Emirates (NCT05069129). Three groups of healthy adults over 18 years of age (600 participants per group) who have administered two doses of BBIBP-CorV 4-6-month, 7-9-month and >9-month earlier, respectively, are randomized 1:1 to receive either a homologous booster of BBIBP-CorV or a heterologous booster of NVSI-06-08. The incidence of adverse reactions is low, and the overall safety profile is quite similar between two booster regimens. Both Neutralizing and IgG antibodies elicited by NVSI-06-08 booster are significantly higher than those by BBIBP-CorV booster against not only SARS-CoV-2 prototype strain but also multiple variants of concerns (VOCs). Especially, the neutralizing antibody GMT against Omicron variant induced by heterologous NVSI-06-08 booster reaches 367.67, which is substantially greater than that boosted by BBIBP-CorV (GMT: 45.03). In summary, NVSI-06-08 is safe and immunogenic as a booster dose following two doses of BBIBP-CorV, which is immunogenically superior to the homologous boost with another dose of BBIBP-CorV.

31 October 2021 in Microbiology Spectrum
Verified
Journal Article
Open access
SMSally Mahmoud
Sally Mahmoud
SGsubhashini ganesan
subhashini ganesan
SNShivaraj Naik
Shivaraj Naik
SBSafaa Bissar
Safaa Bissar
IZIsra Al Zamel
Isra Al Zamel
GKGulfaraz Khan
Gulfaraz Khan
Commercial serological assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are now widely available. This study adds new knowledge regarding the optimization of these assays for evaluating postvaccination antibodies status.

6 June 2022 in Signal Transduction and Targeted Therapy
Verified
Journal Article
Open access
PDF file
NKNawal Al Kaabi
Nawal Al Kaabi
YYYun Kai Yang
Yun Kai Yang
JZJing Zhang
Jing Zhang
KXKe Xu
Ke Xu
YLYu Liang
Yu Liang
QLQi Ming Li
Qi Ming Li
The increased coronavirus disease 2019 (COVID-19) breakthrough cases pose the need of booster vaccination. We conducted a randomised, double-blinded, controlled, phase 2 trial to assess the immunogenicity and safety of the heterologous prime-boost vaccination with an inactivated COVID-19 vaccine (BBIBP-CorV) followed by a recombinant protein-based vaccine (NVSI-06-07), using homologous boost with BBIBP-CorV as control. Three groups of healthy adults (600 individuals per group) who had completed two-dose BBIBP-CorV vaccinations 1–3 months, 4–6 months and ≥6 months earlier, respectively, were randomly assigned in a 1:1 ratio to receive either NVSI-06-07 or BBIBP-CorV boost. Immunogenicity assays showed that in NVSI-06-07 groups, neutralizing antibody geometric mean titers (GMTs) against the prototype SARS-CoV-2 increased by 21.01–63.85 folds on day 28 after vaccination, whereas only 4.20–16.78 folds of increases were observed in control groups. For Omicron variant, the neutralizing antibody GMT elicited by homologous boost was 37.91 on day 14, however, a significantly higher neutralizing GMT of 292.53 was induced by heterologous booster. Similar results were obtained for other SARS-CoV-2 variants of concerns (VOCs), including Alpha, Beta and Delta. Both heterologous and homologous boosters have a good safety profile. Local and systemic adverse reactions were absent, mild or moderate in most participants, and the overall safety was quite similar between two booster schemes. Our findings indicated that NVSI-06-07 is safe and immunogenic as a heterologous booster in BBIBP-CorV recipients and was immunogenically superior to the homologous booster against not only SARS-CoV-2 prototype strain but also VOCs, including Omicron.

17 May 2021 in Journal of Medical Virology
Verified
Journal Article
Open access
PDF file
SMSally Mahmoud
Sally Mahmoud
SGsubhashini ganesan
subhashini ganesan
EIEsra Ibrahim
Esra Ibrahim
BTBhagyashree Thakre
Bhagyashree Thakre
JTJuliet George Teddy
Juliet George Teddy
WZWalid Abbas Zaher
Walid Abbas Zaher
In the current coronavirus disease 2019 (COVID‐19) pandemic there is a mass screening of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) happening around the world due to the extensive spread of the infections. There is a high demand for rapid diagnostic tests to expedite the identification of cases and to facilitate early isolation and control spread. Hence this study evaluates six different rapid nucleic acid detection assays that are commercially available for SARS‐CoV‐2 virus detection. Nasopharyngeal samples were collected from 4981 participants and were tested for the SARS‐CoV‐2 virus by the gold standard real‐time reverse‐transcription polymerase chain reaction (RT‐PCR) method and with one of these six rapid methods of detection. Evaluation of the rapid nucleic acid detection assays was done by comparing the results of these rapid methods with the gold standard RT‐qPCR results for SARS‐COV‐2 detection. AQ‐TOP had the highest sensitivity (98%) and a strong kappa value of 0.943 followed by Genechecker and Abbot ID NOW. The POCKIT (ii RT‐PCR) assay had the highest test accuracy of 99.29% followed by Genechecker and Cobas Liat. Atila iAMP showed the highest percentage of invalid reports (35.5%) followed by AQ‐TOP with 6% and POCKIT with 3.7% of invalid reports. Genechecker system, Abbott ID NOW, and Cobas Liat were found to have the best performance and agreement when compared with the standard RT‐PCR for COVID‐19 detection. With further research, these rapid tests have the potential to be employed in large‐scale screening of COVID‐19.

8 July 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
SHSuad Hannawi
Suad Hannawi
LELinda Saf Eldin
Linda Saf Eldin
AAAlaa Abuquta
Alaa Abuquta
AAAhmad Alamadi
Ahmad Alamadi
SMSally Mahmoud
Sally Mahmoud
LXLiangzhi Xie
Liangzhi Xie
The safety and immunogenicity of a protein-based tetravalent vaccine SCTV01E that contains spike protein ectodomain (S-ECD) of Alpha, Beta, Delta and Omicron BA.1 are assessed and compared with bivalent protein vaccine SCTV01C (Alpha and Beta variants) and monovalent mRNA vaccine (NCT05323461). The primary endpoints are the geometric mean titers (GMT) of live virus neutralizing antibodies (nAb) to Delta (B.1.617.2) and Omicron BA.1 at day 28 post-injection. The secondary endpoints include the safety, day 180 GMTs against Delta and Omicron BA.1, day 28 GMTs to BA.5, and seroresponse rates of neutralizing antibodies and T cell responses at day 28 post-injection. 450 participants, comprising of 449 males and 1 female, with a median age (range) of 27 (18–62) years, are assigned to receive one booster dose of BNT162b2, 20 µg SCTV01C or 30 µg SCTV01E and completed 4-week follow-up. All SCTV01E related adverse events (AEs) are mild or moderate and no Grade ≥3 AE, serious AE or new safety concerns are identified. Day 28 GMT of live virus neutralizing antibodies and seroresponse against Omicron BA.1 and BA.5 with SCTV01E are significantly higher than those with SCTV01C and BNT162b2. These data indicate an overall neutralization superiority with tetravalent booster immunization in men.

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SMSally Mahmoud
Sally Mahmoud
SGsubhashini ganesan
subhashini ganesan
EIEsra Ibrahim
Esra Ibrahim
BTBhagyashree Thakre
Bhagyashree Thakre
JTJuliet G. Teddy
Juliet G. Teddy
WAWalid Z. Abbas
Walid Z. Abbas
In this COVID‐19 pandemic, there is a dire need for cost‐effective and less time‐consuming alternatives for SARS‐CoV‐2 testing. The RNA extraction‐free method for detecting SARS‐CoV‐2 in saliva is a promising option. This study found that it has high sensitivity (85.34%), specificity (95.04%), and was comparable to the gold standard nasopharyngeal swab (NPS) sample tests. The method showed good agreement between salivary and NPS samples, with a kappa coefficient of 0.797. However, there are variations in the sensitivity and specificity based on the RT‐PCR kit used. The Thermo Fisher Applied Biosystems showed high sensitivity, positive predictive value (PPV), and negative predictive value (NPV) but also showed a higher percentage of invalid reports. On the other hand, the BGI kit showed high specificity, better agreement (kappa coefficient) between the results of saliva and NPS samples, and higher correlation between the Ct values of saliva and NPS samples. Thus, the RNA extraction‐free method for salivary sample serves as an effective alternative screening method for COVID‐19.