Objectives: Distal stent graft-induced new entry (dSINE), defined as a new tear caused by a stent graft, has been increasingly observed following total arch replacement using frozen elephant trunk (FET) for aortic dissection. We aimed to investigate the incidence and treatment of dSINE after the use of FET.Methods: This retrospective study evaluated 70 patients who underwent total arch replacement using FET for aortic dissection between August 2014 and March 2020. They were followed up for at least 6 months postoperatively. Between-group comparisons were performed between those who did and did not develop dSINE. The risk factors for the development of dSINE and the treatment of dSINE were analyzed.Results: dSINE occurred postoperatively in nine patients (12.9%) with a median time frame of 17.7±11.7 months. The incidence of dSINE did not differ significantly according to classification, phase of dissection, or oversizing. All patients in the dSINE group developed enlargement of the false lumen. dSINE closure was successfully achieved without complications via thoracic endovascular aortic repair (TEVAR) in all patients.Conclusion: No independent factors predicting the development of dSINE were noted in this study. Additional TEVAR for dSINE provides good results and achieves false lumen thrombosis in the thoracic aorta, with no complications.
OBJECTIVES: This study was conducted to examine the incidence and modes of the bioprosthetic valve failure of the porcine valve in the mitral position and compare them with those of the pericardial valve. METHODS: This study included 240 patients (116 men [48.3%]; mean age, 74.87 ± 6.61 years) who underwent mitral valve replacement using the St. Jude Medical Epic bioprosthesis (Epic) (N = 125) or Carpentier–Edwards Perimount (CEP) pericardial valve (N = 115) from January 2000 to December 2020. RESULTS: The median clinical follow-up durations in the Epic and CEP groups were 54.5 months (range, 0–111 months) and 81.5 months (range, 0–194 months), respectively. Structural valve degeneration (SVD) was observed in 9 patients (7.2%) in the Epic group and 11 patients (9.6%) in the CEP group. The rates of freedom from SVD at 3, 5 and 7 years were 97.7%, 90.5% and 75.5% in the Epic group and 100.0%, 96.1% and 90.0% in the CEP group, respectively. SVD reoperation was performed for 7 patients (5.6%) in the Epic group and 6 patients (5.2%) in the CEP group. The rates of freedom from SVD reoperation at 3, 5 and 7 years were 97.7%, 90.5% and 75.5% in the Epic group and 100%, 96.1% and 90.0% in the CEP group, respectively. Epic SVD was predominantly due to leaflet tearing, whereas CEP SVD was predominantly due to leaflet calcification and adhesion to the subvalvular apparatus. CONCLUSIONS: SVD of the porcine valve was predominantly due to leaflet tearing. The rate of reoperation for SVD was slightly higher for the porcine valve in the mitral position than for the pericardial valve at adjusted survival analysis.
Transcatheter arterial embolisation is often performed for the treatment of visceral artery aneurysms. Here, the case of a patient who developed the rare complication of coil migration into the intestinal tract is reported, and a review of the literature is presented. A 30 year old woman with a ruptured giant common hepatic artery aneurysm, who had been treated with transarterial coil embolisation 1 year previously, was admitted to hospital complaining of passing the coils on defecation. Abdominal Xray and gastroscopy showed the migration of the coils through a duodenal fistula. Open repair was performed with the coils successfully removed and the duodenal fistula closed with omentopexy. At the 3 year follow up, there were no signs or symptoms of complications. Based on observations from this case, although coil migration to the intestinal tract is exceedingly rare, aneurysm rupture with enteric fistula can lead to coil migration.