Modern communication standards, such as 5G new radio (5G NR), require a high speed decoder for highly irregular quasi-cyclic low density parity check (QC-LDPC) codes. A widely used approach in QC-LDPC decoders is a layered decoding schedule which processes the parity check matrix in parts, thus providing faster convergence. However, pipelined layered decoding architecture suffers from data hazards that reduce the throughput. This paper presents a novel architecture, which can facilitate any QC-LDPC decoding without stall cycles caused by pipeline hazards. The decoder conveniently incorporates both the layered and the flooding schedules in cases when hazards occur. The paper also presents the genetic algorithm based optimization of the decoding schedule for better signal-to-noise ratio (SNR) performance. The proposed architecture enables insertion of a large number of pipeline stages, thus providing high operating frequency. As a case study, the FPGA implementation for WiMAX, DVB-S2X, and 5G NR provided coded throughput of up to 1.77 Gbps, 4.32 Gbps, and 4.92 Gbps at 10 iterations, respectively. The results show a strong throughput increase of 30%-109% compared with the conventional layered decoder for 5G NR for the same SNR performance. The decoder provides highly efficient utilization of resources when compared with the state-of-the-art solutions.
6 May 2010 in IEEE Transactions on Instrumentation and Measurement
A simple algorithm (SAL) and a modified SAL (MSAL) for the estimation of the phase difference between two sine-wave signals are proposed. The results obtained by SAL and MSAL in simulations and on real samples are given. A comparison between the phase difference results estimated by MSAL, quadrature delay estimator (QDE), unbiased QDE (UQDE), three-parameter sine-fitting algorithm (3PSF), four-parameter sine-fitting algorithm (4PSF), and seven-parameter sine-fitting algorithm (7PSF) is presented. The requirements for the application of SAL and MSAL are analyzed.
1 January 2012 in Journal of NeuroEngineering and Rehabilitation
The control of movement in humans is hierarchical and distributed and uses feedback. An assistive system could be best integrated into the therapy of a human with a central nervous system lesion if the system is controlled in a similar manner. Here, we present a novel wireless architecture and routing protocol for a distributed functional electrical stimulation system that enables control of movement.
1 April 2017 in Biomedical Signal Processing and Control
Background: The Electrocardiogram ECG is one of the most important non-invasive tools for cardiac diseases diagnosis. Taking advantage of the developed telecommunication infrastructure, several approaches that address the development of telemetry cardiac devices were introduced recently. Telemetry ECG devices allow easy and fast ECG monitoring of patients with suspected cardiac issues. Choosing the right device with the desired working mode, signal quality, and the device cost are still the main obstacles to massive usage of these devices. Methods: In this paper, we introduce design, implementation, and validation of a multi-purpose telemetry system for recording, transmission, and interpretation of ECG signals in different recording modes. The system consists of an ECG device, a cloud-based analysis pipeline, and accompanied mobile applications for physicians and patients. The proposed ECG device’s mechanical design allows laypersons to easily record post-event short-term ECG signals, using dry electrodes without any preparation. Moreover, patients can use the device to record long-term signals in loop and holter modes, using wet electrodes. In order to overcome the problem of signal quality fluctuation due to using different electrodes types and different placements on subject’s chest, customized ECG signal processing and interpretation pipeline is presented for each working mode. Results: We present the evaluation of the novel short-term recorder design. Recording of an ECG signal was performed for 391 patients using a standard 12-leads golden standard ECG and the proposed patient-activated short-term post-event recorder. In the validation phase, a sample of validation signals followed peer review process wherein two experts annotated the signals in terms of signal acceptability for diagnosis.We found that 96% of signals allow detecting arrhythmia and other signal’s abnormal changes. Additionally, we compared and presented the correlation coefficient and the automatic QRS delineation results of both short-term post-event recorder and 12-leads golden standard ECG recorder. Conclusions: The proposed multi-purpose ECG device allows physicians to choose the working mode of the same device according to the patient status. The proposed device was designed to allow patients to manage the technical requirements of both working modes. Post-event short-term ECG recording using the proposed design provide physicians reliable three ECG leads with direct symptom-rhythm correlation.