Lauren E. Gibson

Dr. Lauren E. Gibson

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2020 in Postgraduate Medicine
Verified
Journal Article
Closed access
GWGabrielle White-Dzuro
Gabrielle White-Dzuro
LGLauren E. Gibson
Lauren E. Gibson
LZLuca Zazzeron
Luca Zazzeron
CWColin White-Dzuro
Colin White-Dzuro
ZSZachary Sullivan
Zachary Sullivan
EBEdward A. Bittner
Edward A. Bittner
While COVID-19 has primarily been characterized by the respiratory impact of viral pneumonia, it affects every organ system and carries a high consequent risk of death in critically ill patients. Higher sequential organ failure assessment (SOFA) scores have been associated with increased mortality in patients critically ill patients with COVID-19. It is important that clinicians managing critically ill COVID-19 patients be aware of the multisystem impact of the disease so that care can be focused on the prevention of end-organ injuries to potentially improve clinical outcomes. We review the multisystem complications of COVID-19 and associated treatment strategies to improve the care of critically ill COVID-19 patients.

11 December 2020 in Journal of Intensive Care
Verified
Journal Article
Open access
PDF file
LGLauren E. Gibson
Lauren E. Gibson
GWGabrielle A. White-Dzuro
Gabrielle A. White-Dzuro
PLPatrick J. Lindsay
Patrick J. Lindsay
SBSheri M. Berg
Sheri M. Berg
EBEdward A. Bittner
Edward A. Bittner
MCMarvin G. Chang
Marvin G. Chang
Background: Focused cardiac ultrasound (FoCUS) is a valuable skill for rapid assessment of cardiac function and volume status. Despite recent widespread adoption among physicians, there is limited data on the optimal training methods for teaching FoCUS and metrics for determining competency. We conducted a systematic review to gain insight on the optimal training strategies, including type and duration, that would allow physicians to achieve basic competency in FoCUS. Methods: Embase, PubMed, and Cochrane Library databases were searched from inception to June 2020. Included studies described standardized training programs for at least 5 medical students or physicians on adult FoCUS, followed by an assessment of competency relative to an expert. Data were extracted, and bias was assessed for each study. Results: Data were extracted from 23 studies on 292 learners. Existing FoCUS training programs remain varied in duration and type of training. Learners achieved near perfect agreement (κ > 0.8) with expert echocardiographers on detecting left ventricular systolic dysfunction and pericardial effusion with 6 h each of didactics and hands-on training. Substantial agreement (κ > 0.6) on could be achieved in half this time. Conclusion: A short training program will allow most learners to achieve competency in detecting left ventricular systolic dysfunction and pericardial effusion by FoCUS. Additional training is necessary to ensure skill retention, improve efficiency in image acquisition, and detect other pathologies.

30 March 2021 in Journal of Intensive Care Medicine
Verified
Journal Article
Open access
PDF file
LGLauren E. Gibson
Lauren E. Gibson
RFRaffaele Di Fenza
Raffaele Di Fenza
MLMin Lang
Min Lang
MCMartin I. Capriles
Martin I. Capriles
MLMatthew D. Li
Matthew D. Li
MCMarvin G Chang
Marvin G Chang
Background: Right ventricular (RV) dysfunction is common and associated with worse outcomes in patients with coronavirus disease 2019 (COVID-19). In non-COVID-19 acute respiratory distress syndrome, RV dysfunction develops due to pulmonary hypoxic vasoconstriction, inflammation, and alveolar overdistension or atelectasis. Although similar pathogenic mechanisms may induce RV dysfunction in COVID-19, other COVID-19-specific pathology, such as pulmonary endothelialitis, thrombosis, or myocarditis, may also affect RV function. We quantified RV dysfunction by echocardiographic strain analysis and investigated its correlation with disease severity, ventilatory parameters, biomarkers, and imaging findings in critically ill COVID-19 patients. Methods: We determined RV free wall longitudinal strain (FWLS) in 32 patients receiving mechanical ventilation for COVID-19-associated respiratory failure. Demographics, comorbid conditions, ventilatory parameters, medications, and laboratory findings were extracted from the medical record. Chest imaging was assessed to determine the severity of lung disease and the presence of pulmonary embolism. Results: Abnormal FWLS was present in 66% of mechanically ventilated COVID-19 patients and was associated with higher lung compliance (39.6 vs 29.4 mL/cmH2O, P = 0.016), lower airway plateau pressures (21 vs 24 cmH2O, P = 0.043), lower tidal volume ventilation (5.74 vs 6.17 cc/kg, P = 0.031), and reduced left ventricular function. FWLS correlated negatively with age (r = −0.414, P = 0.018) and with serum troponin (r = 0.402, P = 0.034). Patients with abnormal RV strain did not exhibit decreased oxygenation or increased disease severity based on inflammatory markers, vasopressor requirements, or chest imaging findings. Conclusions: RV dysfunction is common among critically ill COVID-19 patients and is not related to abnormal lung mechanics or ventilatory pressures. Instead, patients with abnormal FWLS had more favorable lung compliance. RV dysfunction may be secondary to diffuse intravascular micro- and macro-thrombosis or direct myocardial damage. Trial Registration: National Institutes of Health #NCT04306393. Registered 10 March 2020, https://clinicaltrials.gov/ct2/show/NCT04306393

1 August 2020 in Critical Care Explorations
Verified
Journal Article
Open access
LGLauren E. Gibson
Lauren E. Gibson
RFRaffaele Di Fenza
Raffaele Di Fenza
LBLorenzo Berra
Lorenzo Berra
EBEdward A. Bittner
Edward A. Bittner
MCMarvin G. Chang
Marvin G. Chang
Objectives: Patients with acute respiratory distress syndrome are at risk for developing cardiac dysfunction which is independently associated with worse outcomes. Transthoracic echocardiography is an ideal imaging modality for goal-directed assessment and optimization of cardiac function and volume status. Prone positioning, while demonstrated to improve oxygenation, offload the right ventricle, and reduce short-term mortality in acute respiratory distress syndrome, has previously precluded transthoracic echocardiography on these patients. The purpose of this study was to assess the ability to perform focused transthoracic echocardiography examinations on acute respiratory distress syndrome patients in the prone position. Design: We performed a cross-sectional study of critically ill patients hospitalized for acute respiratory distress syndrome due to coronavirus disease 2019. Setting: This study was conducted in medical and surgical intensive units in a tertiary hospital. Patients: We examined 27 mechanically ventilated and prone patients with acute respiratory distress syndrome due to coronavirus disease 2019. Participants were examined at the time of enrollment in an ongoing clinical trial (NCT04306393), and no patients were excluded from echocardiographic analysis. Interventions: None. Measurements and Main Results: We were able to perform transthoracic echocardiography and obtain satisfactory images for quantitative assessment of right ventricular function in 24 out of 27 (88.9%) and left ventricular function in 26 out of 27 (96.3%) of patients in the prone position, including many who were obese and on high levels of positive end-expiratory pressure (≥ 15 cm H2O). Conclusions: Transthoracic echocardiography can be performed at the prone patient’s bedside by critical care intensivists. These findings encourage the use of focused transthoracic echocardiography for goal-directed cardiac assessment in acute respiratory distress syndrome patients undergoing prone positioning.

1 June 2020 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
LGLauren E. Gibson
Lauren E. Gibson
Teresa HenriquesTeresa Henriques
Teresa Henriques
MCMadalena D. Costa
Madalena D. Costa
RDRoger B. Davis
Roger B. Davis
MMMurray A. Mittleman
Murray A. Mittleman
BSBalachundhar Subramaniam
Balachundhar Subramaniam
BACKGROUND: Continuous arterial blood pressure (ABP) is typically recorded by placement of an intraarterial catheter. Recently, noninvasive ABP monitors have been shown to be comparable in accuracy to invasive measurements. In a previous study, we showed that the fluctuations in beat-to-beat ABP measurements were not random variations but had a complex dynamical structure, and that ABP dynamical complexity was inversely associated with surgical risk estimated using the Society of Thoracic Surgeons (STS) index. Dynamical complexity is a mathematical construct that reflects the capacity of a physiological system to adapt to stimuli. The objectives of present study were to: (1) determine whether noninvasive beat-to-beat ABP measurements also exhibit a complex temporal structure; (2) compare the complexity of noninvasive versus invasive ABP time series; and (3) quantify the relationship between the complexity of noninvasive ABP time series and the STS risk scores. METHODS: Fifteen adult patients undergoing coronary artery bypass graft, valve, or combined coronary artery bypass graft/valve surgery were enrolled in this observational study. Preoperative ABP waveforms were simultaneously recorded for ≥15 minutes using a radial artery catheter (invasive) and a continuous noninvasive arterial pressure monitor. Beat-to-beat systolic blood pressure (SBP), diastolic blood pressure (DBP), pulse pressure (PP), and mean arterial pressure (MAP) time series were extracted from the continuous waveforms. Complexity was assessed using the multiscale entropy method. The Wilcoxon signed-rank test was used to compare the mean ranks of indices derived from invasive versus noninvasive ABP time series. Spearman correlation coefficients were used to quantify the relationship between invasive and noninvasive indices. Linear regression analysis was used to quantify the association between each of the complexity indices and the STS risk scores. RESULTS: Beat-to-beat fluctuations in noninvasive ABP measurements were not random but complex; however, their degree of complexity was lower than that of fluctuations in invasively obtained ABP signals (SBP: 7.05 vs 8.66, P < .001; DBP: 7.40 vs 8.41, P < .001; PP: 6.83 vs 8.82, P < .001; and MAP: 7.17 vs 8.68, P < .005). Invasive and noninvasive indices for MSEΣ·slope showed good correlation (r s) (0.53 for SBP, 0.79 for DBP, 0.42 for PP, 0.60 for MAP). The complexity of noninvasive ABP time series (−0.70 [−1.28 to −0.11]; P = .023 for DBP), like that of invasive time series (−0.94 [−1.52 to −0.35]; P = .004 for DBP), was inversely associated with estimated surgical risk in patients undergoing cardiovascular operations. CONCLUSIONS: Our results support the use of noninvasive ABP monitoring in computations of complexity-based indices that correlate with estimated surgical risk.

8 December 2021 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
LGLauren E. Gibson
Lauren E. Gibson
AKAnders S. Knudsen
Anders S. Knudsen
DADavid Arney
David Arney
HDHao Deng
Hao Deng
NSNathaniel M. Sims
Nathaniel M. Sims
RPRobert A. Peterfreund
Robert A. Peterfreund