Mohamed Yateh

Dr. Mohamed Yateh

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2024 in Journal of Cleaner Production
Verified
Journal Article
Closed access
MYMohamed Yateh
Mohamed Yateh
FLFengting Li
Fengting Li
YTYuling Tang
Yuling Tang
CLCheng Li
Cheng Li
BXBin Xu
Bin Xu

29 October 2021 in Water
Verified
Journal Article
Open access
PDF file
XQXinlu Qu
Xinlu Qu
HWHaowei Wu
Haowei Wu
Tian-Yang ZhangTian-Yang Zhang
Tian-Yang Zhang
QLQianhong Liu
Qianhong Liu
MWMu Wang
Mu Wang
Yulin TangYulin Tang
Yulin Tang
As an emerging light source, ultraviolet light emitting diodes (UV-LEDs) are adopted to overcome the shortcomings of the conventional mercury lamp, such as mercury pollution. The degradation of chloramphenicol (CAP) using three UV-LED-based advanced oxidation processes (AOPs)—UV-LED/persulfate (UV-LED/PS), UV-LED/peroxymonosulfate (UV-LED/PMS) and UV-LED/chlorine—was investigated. Results indicate that CAP can be more effectively degraded by the hybrid processes when compared to UV irradiation and oxidants alone. Degradation of CAP using the three UV-LED-based AOPs followed pseudo-first-order kinetics. The degradation rate constants (kobs) for UV-LED/PS, UV-LED/PMS, and UV-LED/chlorine were 0.0522, 0.0437 and 0.0523 min−1, and the CAP removal rates 99%, 98.1% and 96.3%, respectively. The degradation rate constant (kobs) increased with increasing oxidant dosage for UV-LED/chlorine, whereas overdosing reduced CAP degradation using UV-LED/PS and UV-LED/PMS. Ultraviolet wavelength influenced degradation efficiency of the UV-LED based AOPs with maximum CAP degradation observed at a wavelength of 280 nm. The application of UV-LED enhanced the formation DBPs during subsequent chlorination. uUV-LED/PMS produced more disinfection by-products than UV-LED/PS. Compared to UV-LED, UV-LED/PS reduced the formation of dichloroacetonitrile and trichloronitromethane during chlorination owing to its capacity to degrade the nitro group in CAP. The intermediates dichloroacetamide, 4-nitrobenzoic acid, 4-nitrophenol were produced during the degradation of CAP using each of UV-LED, UV-LED/PS and UV-LED/chlorine. The present study provides further evidence supporting the application of UV-LED in AOPs.

22 February 2023 in Water
Verified
Journal Article
Open access
PDF file
MYMohamed Yateh
Mohamed Yateh
GLGeorge Lartey-Young
George Lartey-Young
FLFengting Li
Fengting Li
MLMei Li
Mei Li
Yulin TangYulin Tang
Yulin Tang
Many coagulants such as aluminium sulfate, ferric sulfate, and ferrous sulfate have been investigated in the past, but there is a lack of data on their effectiveness to some specific water quality parameters. This study aimed at investigating the efficiency of the coagulation water treatment process to remove pollutants such as total organic carbon (TOC), total nitrogen (TN), and total suspended solids (TSS) from urban drinking water. The polyaluminium chloride (PAC) coagulant was applied to determine the impact of the treatment process on the structure and diversity of these pollutants in urban drinking water. All water samples were collected from the Yangtze River, Baoshan district, Shanghai, China, over a period of three months which coincided with the late summer and early winter periods. Specific to different coagulant characterizations, a preliminary test was performed with three other coagulants, namely, aluminium sulfate, polyaluminium, silicate sulfate, and ferric sulfate to determine their optimal conditions for floc characterization and removal efficiencies. In summary, the overall performance of the PAC coagulant was better than that of the other three coagulants used in the pre-treatment of the sampled water. The obtained results revealed that under the optimum operating conditions, the doses of the PAC were as follows: 20, 35, 50, 65, and 80 mgL−1, respectively. The water temperature and pH were determined by using a pH meter, the TOC and TN determined by using a TOC analyzer, and the TSS by following the ASTM D2540 method. Furthermore, the response surface methodology by the Box–Behnken optimization analysis was applied to coagulant dosage, temperature, pH, and three corresponding dependent factors (TSS, TOC, and TN) to determine the best optimal conditions for the PAC performance. To determine whether or not the quadratic model adequately explained and predicted the response during the coagulation process, an analysis of variance was performed. Multiple optimal factors were identified for the urban drinking water treatment, including a pH value of 6.9, water temperature of 20.1 °C, and a coagulant dosage of 9.7 mgL−1.