Hu Yiqi

Mr. Hu Yiqi


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 February 2024 in Materials
Verified
Journal Article
Open access
PDF file
HFHenghui Fan
Henghui Fan
CWCheng Wang
Cheng Wang
HYHu Yiqi
Hu Yiqi
Gaowen ZhaoGaowen Zhao
Gaowen Zhao
In salt lake areas, cast-in situ concrete structures are subjected to long-term corrosion by sulfate and magnesium ions. The properties of concrete can be improved by adding materials like basalt fiber (BF). To investigate the degradation process and mechanism of cast-in situ concrete with premixed BF under the dual corrosion of sulfate and magnesium salts, concrete with a content of BF ranging from 0 to 0.5% was prepared. Specimens were subjected to different internal and external corrosion conditions and immersed for 180 days. Dimension, mass, and appearance changes at different immersion times were recorded. The compressive and flexural strength of the specimens were tested and continually observed throughout the immersion time. Mineral and microstructural changes at different immersion times were determined by the XRD, TG, and SEM analysis methods. Results indicated that external sulfate–internal magnesium combined attack had a significant negative effect on the early strength. The compressive and flexural strength of the corroded specimens decreased by 17.2% and 14.1%, respectively, compared to the control group at 28 days. The premixed magnesium ions caused the decomposition of the C-S-H gel, resulting in severe spalling and lower mechanical properties after immersing for a long time. As the BF can inhibit crack development, the properties of the concrete premixed with BF were improved. Specimens exhibited superior performance at a BF content of 0.5%, resulting in a 16.2% increase in flexural strength. This paper serves as a valuable reference for the application of basalt fiber-reinforced concrete under the challenging conditions of sulfate–magnesium combined attack.

21 April 2023 in Buildings
Verified
Journal Article
Open access
PDF file
XLXigang Liu
Xigang Liu
JZJian Zhang
Jian Zhang
HYHu Yiqi
Hu Yiqi
JLJiao Liu
Jiao Liu
SDShijun Ding
Shijun Ding
ZNZhibao Nie
Zhibao Nie
The construction of transformer substations in transmission lines is a systematic, technical, and complex project with the need for numerous materials and resources. Under the development of the green economy, the requirements for energy conservation and carbon reduction have improved; hence, an assessment of carbon emissions in transformer substations is urgently needed. A calculation method was proposed in the present study to analyze the carbon emissions of transformer substations with different kinds of data sources, which were collected from several practical projects in the west-to-east power transmission project. In this study, a detailed comparison and discussion regarding the differences in carbon emissions of 750 kV transformer substations caused by hydrology, geology, engineering quantity, and other factors were conducted. The mean value, standard deviation, and 90% confidence interval of carbon emissions were obtained by Monte Carlo simulation through MATLAB. Results show that the total carbon emissions of the selected 750 kV transformer substations are between [56,000, 68,000] t CO2 eq. Construction engineering accounts for more than 50% of carbon emissions, followed by installation engineering and additional services. In terms of input items, electricity distribution buildings contribute more than 39% of total carbon emissions, followed by cable/earthing systems, which account for 14% of total carbon emissions. Gas insulated switchgear (GIS) and air insulated switchgear (AIS) could adopt different types of equipment foundations, and GIS equipment foundations would generate fewer carbon emissions due to the smaller land area and input materials. This study can provide experience and reference for similar projects and further guide the substation carbon emission reduction work.