Bohua Zhang

Dr. Bohua Zhang

Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, North Carolina, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2021 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
LGLeela Goel
Leela Goel
HWHuaiyu Wu
Huaiyu Wu
Bohua ZhangBohua Zhang
Bohua Zhang
Jinwook KimJinwook Kim
Jinwook Kim
PDPaul A. Dayton
Paul A. Dayton
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang
One major challenge in current microbubble (MB) and tissue plasminogen activator (tPA)-mediated sonothrombolysis techniques is effectively treating retracted blood clots, owing to the high density and low porosity of retracted clots. Nanodroplets (NDs) have the potential to enhance retracted clot lysis owing to their small size and ability to penetrate into retracted clots to enhance drug delivery. For the first time, we demonstrate that a sub-megahertz, forward-viewing intravascular (FVI) transducer can be used for ND-mediated sonothrombolysis, in vitro. In this study, we determined the minimum peak negative pressure to induce cavitation with low-boiling point phase change nanodroplets and clot lysis. We then compared nanodroplet mediated sonothrombolysis to MB and tPA mediate techniques. The clot lysis as a percent mass decrease in retracted clots was 9 ± 8%, 9 ± 5%, 16 ± 5%, 14 ± 9%, 17 ± 9%, 30 ± 8%, and 40 ± 9% for the control group, tPA alone, tPA + US, MB + US, MB + tPA + US, ND + US, and ND + tPA + US groups, respectively. In retracted blood clots, combined ND- and tPA-mediated sonothrombolysis was able to significantly enhance retracted clot lysis compared with traditional MB and tPA-mediated sonothrombolysis techniques. Combined nanodroplet with tPA-mediated sonothrombolysis may provide a feasible strategy for safely treating retracted clots.

1 September 2019 in Ultrasonics
Verified
Journal Article
Closed access
Bohua ZhangBohua Zhang
Bohua Zhang
HKHowuk Kim
Howuk Kim
HWHuaiyu Wu
Huaiyu Wu
YGYu Gao
Yu Gao
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang

13 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
XXXiangming Xue
Xiangming Xue
Bohua ZhangBohua Zhang
Bohua Zhang
SMSunho Moon
Sunho Moon
GXGuo-Xuan Xu
Guo-Xuan Xu
Chih-Chung HuangChih-Chung Huang
Chih-Chung Huang
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang
Robotic prostheses and powered exoskeletons are novel assistive robotic devices for modern medicine. Muscle activity sensing plays an important role in controlling assistive robotics devices. Most devices measure the surface electromyography (sEMG) signal for myoelectric control. However, sEMG is an integrated signal from muscle activities. It is difficult to sense muscle movements in specific small regions, particularly at different depths. Alternatively, traditional ultrasound imaging has recently been proposed to monitor muscle activity due to its ability to directly visualize superficial and at-depth muscles. Despite their advantages, traditional ultrasound probes lack wearability. In this paper, a wearable ultrasound (US) transducer, based on lead zirconate titanate (PZT) and a polyimide substrate, was developed for a muscle activity sensing demonstration. The fabricated PZT-5A elements were arranged into a 4 × 4 array and then packaged in polydimethylsiloxane (PDMS). In vitro porcine tissue experiments were carried out by generating the muscle activities artificially, and the muscle movements were detected by the proposed wearable US transducer via muscle movement imaging. Experimental results showed that all 16 elements had very similar acoustic behaviors: the averaged central frequency, −6 dB bandwidth, and electrical impedance in water were 10.59 MHz, 37.69%, and 78.41 Ω, respectively. The in vitro study successfully demonstrated the capability of monitoring local muscle activity using the prototyped wearable transducer. The findings indicate that ultrasonic sensing may be an alternative to standardize myoelectric control for assistive robotics applications.

1 September 2021 in Ultrasonics
Verified
Journal Article
Closed access
Bohua ZhangBohua Zhang
Bohua Zhang
HWHuaiyu Wu
Huaiyu Wu
LGLeela Goel
Leela Goel
HKHowuk Kim
Howuk Kim
CPChang Peng
Chang Peng
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang

9 August 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HWHuaiyu Wu
Huaiyu Wu
LGLeela Goel
Leela Goel
HKHowuk Kim
Howuk Kim
Bohua ZhangBohua Zhang
Bohua Zhang
Jinwook KimJinwook Kim
Jinwook Kim
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang
Thrombo-occlusive disease is one of the leading causes of death worldwide. There has been active research on safe and effective thrombolysis in preclinical and clinical studies. Recently, the dual-frequency transcutaneous sonothrombolysis with contrast agents [microbubbles (MBs)] has been reported to be more efficient in trigging the acoustic cavitation, which leads to a higher lysis rate. Therefore, there is increasing interest in applying dual-frequency technique for more significant efficacy improvement in intravascular sonothrombolysis since a miniaturized intravascular ultrasound transducer typically has a limited power output to fully harness cavitation effects. In this work, we demonstrated this efficacy enhancement by developing a new broadband intravascular transducer and testing dual-frequency sonothromblysis in vitro . A broadband intravascular transducer with a center frequency of 750 kHz and a footprint size of 1.4 mm was designed, fabricated, and characterized. The measured −6-dB fractional bandwidth is 68.1%, and the peak negative pressure is 1.5 MPa under the driving voltage of 80 V pp . By keeping one frequency component at 750 kHz, the second frequency component was selected from 450 to 650 kHz with an interval of 50 kHz. The in vitro sonothrombolysis tests were conducted with a flow model and the results indicated that the MB-mediated, dual-frequency (750+500 kHz) sonothrombolysis yields an 85% higher lysis rate compared with the single-frequency treatment, and the lysis rate of dual-frequency sonothrombolysis increases with the difference between the two frequency components. These findings suggest a dual-frequency excitation technique for more efficient intravascular sonothrombolysis than conventional single-frequency excitation

1 September 2021 in Ultrasonics
Verified
Journal Article
Closed access
HKHowuk Kim
Howuk Kim
Jinwook KimJinwook Kim
Jinwook Kim
HWHuaiyu Wu
Huaiyu Wu
Bohua ZhangBohua Zhang
Bohua Zhang
PDPaul A. Dayton
Paul A. Dayton
Xiaoning JiangXiaoning Jiang
Xiaoning Jiang