Giacomo Mugnai

Dr. Giacomo Mugnai

1. Electrophysiology and Cardiac Pacing, Division of Cardiology, Cardio-Thoracic Department, School of Medicine, University Hospital of Verona, 37126 Verona, Italy
+1

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2017 in European Heart Journal
Verified
Journal Article
Open access
PDF file
JSJuan Sieira
Juan Sieira
GCGiulio Conte
Giulio Conte
GCGiuseppe Ciconte
Giuseppe Ciconte
GCGian-Battista Chierchia
Gian-Battista Chierchia
RARuben Casado Arroyo
Ruben Casado Arroyo
PBPedro Brugada
Pedro Brugada
Aims: Risk stratification in Brugada Syndrome (BS) remains challenging. Arrhythmic events can occur life-long and studies with long follow-ups are sparse. The aim of our study was to investigate long-term prognosis and risk stratification of BS patients. Methods and results: A single centre consecutive cohort of 400 BS patients was included and analysed. Mean age was 41.1 years, 78 patients (19.5%) had a spontaneous type I electrocardiogram (ECG). Clinical presentation was aborted sudden cardiac death (SCD) in 20 patients (5.0%), syncope in 111 (27.8%) and asymptomatic in 269 (67.3%). Familial antecedents of SCD were found in 184 individuals (46.0%), in 31 (7.8%) occurred in first-degree relatives younger than 35 years. An implantable cardioverter defibrillator (ICD) was placed in 176 (44.0%). During a mean follow-up of 80.7 months, 34 arrhythmic events occurred (event rate: 1.4% year). Variables significantly associated to events were: presentation as aborted SCD (Hazard risk [HR] 20.0), syncope (HR 3.7), spontaneous type I (HR 2.7), male gender (HR 2.7), early SCD in first-degree relatives (HR 2.9), SND (HR 5.0), inducible VA (HR 4.7) and proband status (HR 2.1). A score including ECG pattern, early familial SCD antecedents, inducible electrophysiological study, presentation as syncope or as aborted SCD and SND had a predictive performance of 0.82. A score greater than 2 conferred a 5-year event probability of 9.2%. Conclusions: BS patients remain at risk many years after diagnosis. Early SCD in first-degree relatives and SND are risk factors for arrhythmic events. A simple risk score might help in the stratification and management of BS patients.

1 April 2015 in Heart Rhythm
Verified
Journal Article
Closed access
GCGiuseppe Ciconte
Giuseppe Ciconte
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
JSJuan Sieira
Juan Sieira
GCGiulio Conte
Giulio Conte
GGGiacomo Di Giovanni
Giacomo Di Giovanni
GCGian-Battista Chierchia
Gian-Battista Chierchia

9 April 2014 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
GGGiacomo DI Giovanni
Giacomo DI Giovanni
KWKristel Wauters
Kristel Wauters
GCGian‐Battista Chierchia
Gian‐Battista Chierchia
JSJuan Sieira
Juan Sieira
MLMoises Levinstein
Moises Levinstein
PBPedro Brugada
Pedro Brugada

1 February 2016 in Heart Rhythm
Verified
Journal Article
Open access
AAArash Aryana
Arash Aryana
Giacomo MugnaiGiacomo Mugnai
Giacomo Mugnai
SSSheldon M. Singh
Sheldon M. Singh
DPDeep K. Pujara
Deep K. Pujara
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
GCGian-Battista Chierchia
Gian-Battista Chierchia
Limited data exist on procedural and biophysical indicators of pulmonary vein (PV) isolation durability after the cryoballoon ablation of atrial fibrillation (AF). The aim of this study was to investigate the procedural and biophysical characteristics associated with late PV reconnection (PVR) and durable PV isolation (PVI) after cryoablation using the currently available second-generation cryoballoon. Data from 435 PVs targeted in 112 consecutive patients who underwent a repeat procedure 14 ± 3 months after an index cryoablation of AF were examined. Altogether, 111 PVs (25.5%) in 71 patients (63.4%) demonstrated PVR, whereas 324 PVs (74.5%) exhibited PVI. The number and duration of cryoballoon applications did not differ between PVR and PVI. However, the time to PV isolation (time to effect) was considerably shorter (39.1 ± 11.7 seconds vs 67.6 ± 19.7 seconds; P < .001), the balloon temperature at time to effect was significantly warmer (-32.1°C ± 7.8°C vs -39.4°C ± 5.8°C; P < .001), the balloon nadir temperature was slightly cooler (-48.7°C ± 4.6°C vs -47.8°C ± 2.9°C; P = .034), and the total thaw time (56.5 ± 25.4 seconds vs 34.8 ± 9.1 seconds; P < .001) and interval thaw times at 0°C (iTT0; 14.8 ± 10.9 seconds vs 7.1 ± 2.0 seconds; P < .001) and 15°C (54.2 ± 25.4 seconds vs 33.3 ± 9.1 seconds; P < .001) were notably longer with PVI than with PVR. However, only a time to effect of ≤60 seconds and an iTT0 of ≥10 seconds emerged as significant predictors of PV isolation durability. Consequently, in a multivariate model, presence of both criteria predicted <1% and their mere absence ~75% likelihood of PVR. A time to effect of ≤60 seconds and an iTT0 of ≥10 seconds significantly predict PV isolation durability after the cryoballoon ablation of AF. If both criteria are met, the likelihood of PV reconnection may be exceedingly low.

28 January 2014 in EP Europace
Verified
Journal Article
Open access
PDF file
GCGian-Battista Chierchia
Gian-Battista Chierchia
GGGiacomo Di Giovanni
Giacomo Di Giovanni
GCGiuseppe Ciconte
Giuseppe Ciconte
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
GCGiulio Conte
Giulio Conte
PBPedro Brugada
Pedro Brugada
BackgroundThe novel cryoballoon Advance (CB-A) has proven to achieve significantly lower temperatures and faster pulmonary vein isolation (PVI) times in comparison with the first-generation device. Although acutely very effective, to the best of our knowledge, data on mid-term clinical follow-up is lacking.AimsThe aim of the study was to analyse the freedom from recurrence of atrial fibrillation (AF) on a 1-year follow-up period, in a series of consecutive patients having undergone PVI with the CB-A for paroxysmal AF (PAF).Methods and resultsForty-two patients [30 male (71%); mean age: 57.9 ± 21.1 years] were included. All patients underwent a procedure with the large 28 mm CB-A. A total 168 PVs were depicted on the pre-procedural computed tomography scan. All PVs (100%) could be isolated with the CB only. The freedom from AF off-antiarrhythmic drug treatment after a single procedure was 78% of patients at a mean 11.6 ± 2.0 months follow-up. If considering a blanking period (BP) of 3 months, success rate was 83%. Phrenic nerve palsy (PNP) was the most frequent complication occurring in 19% of individuals.ConclusionThe CB-A is very effective in producing PVI and affords freedom from AF at 12 months follow-up in 83% of patients affected by drug-resistant PAF following a 3-month BP. The most frequent complication observed was PNP which occurred in 19% of patients. All PNP reverted during follow-up.

1 December 2015 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
GCGiuseppe Ciconte
Giuseppe Ciconte
Giacomo MugnaiGiacomo Mugnai
Giacomo Mugnai
JSJuan Sieira
Juan Sieira
VVVedran Velagić
Vedran Velagić
YSYukio Saitoh
Yukio Saitoh
GCGian-Battista Chierchia
Gian-Battista Chierchia
Background—: The second-generation cryoballoon is effective in achieving acute pulmonary vein isolation (PVI) and favorable clinical outcome. To date, no data are available on factors affecting late PV reconnection after second-generation cryoballoon ablation. Methods and Results—: A total of 29 consecutive patients (25 male, 86.2%; mean age 57.8±13.8 years) underwent a repeat procedure, after a mean 11.6±4.5 months (range, 3.5–19.7 months), after index ablation using the 28-mm second-generation cryoballoon. All repeat ablations were performed using a 3-dimensional electroanatomical mapping system. Among all 115 PVs, including 1 left common ostiums (LCOs), 25 (21.7%) showed a PV reconnection in 20 patients (1.25 per patient). Persistent PVI could be documented in 90 of 115 PVs (78.2%). In 9 of 29 patients (31%), all PVs were electrically isolated. In the multivariable analysis, time to PVI ( P =0.03) and failure to achieve −40°C within 60 s ( P =0.05) independently predicted late PV reconnection. At receiver-operator curve analysis, time to PVI <60 s identified the absence of PV reconduction (sensitivity, 86.7%; specificity, 86.2%; positive predictive value, 59.1%; and negative predictive value, 96.4%; area under the curve, 0.85; confidence interval, 0.73–0.97; P <0.001). Conclusions—: The rate of late PV reconnection after second-generation cryoballoon ablation is low (1.25 PVs/patient). Faster time to isolation and achievement of −40°C within 60 s independently predict durable PVI. In addition, 60-s cut-off for time to PVI indicates persistent isolation with 96.4% negative predictive value. These parameters might guide the operator whether to perform further applications to ensure a long-lasting PVI.