1 June 2020 in JACC: Clinical Electrophysiology
Verified
Journal Article
Open access
VRVivek Y. Reddy
Vivek Y. Reddy
PNPetr Neužil
Petr Neužil
PPPetr Peichl
Petr Peichl
GRGediminas Rackauskas
Gediminas Rackauskas
EAElad Anter
Elad Anter
JKJosef Kautzner
Josef Kautzner
This study was designed to evaluate lesion durability on invasive electrophysiologic remapping. The lattice-tip catheter generates a large thermal footprint during temperature-controlled irrigated radiofrequency ablation. In a first-in-human study, this catheter performed rapid point-by-point pulmonary vein isolation (PVI) and other linear atrial ablations. In a prospective 3-center single-arm study, paroxysmal or persistent atrial fibrillation patients underwent PVI and, as needed, linear ablation at the cavotricuspid isthmus (CTI), mitral isthmus (MI), and/or left atrial roof; no other atrial substrate was ablated. Using the lattice catheter and a custom electroanatomic mapping system, temperature-controlled (Tmax 73° to 80°C; 2 to 7 s) point-by-point ablation was performed. Patients were followed for 12 months. A total of 65 patients (61.5% paroxysmal/38.5% persistent) underwent ablation: PVI in 65, MI in 22, left atrial roof in 24, and CTI in 48 patients. At a median of 108 days after the index procedure, protocol-mandated remapping was performed in 27 patients. The pulmonary veins (PVs) remained durably isolated in all but 1 reconnected PV-translating to durable isolation in 99.1% of PVs, or 96.3% of patients with all PVs isolated. Of 47 linear atrial lesions initially placed during the index procedure, durability was observed in 10 of 11 (90.9%) MI lines, all 11 (100%) roof lines, and all 25 (100%) CTI lines. After a median follow-up of 270 days, the 12-month Kaplan-Meier estimate for freedom from atrial arrhythmias was 94.4 ± 3.2%. Temperature-controlled lattice-tip point-by-point ablation showed not only highly durable PVI lesion sets, but also durable contiguity of linear atrial lesions.

1 February 2020 in Heart Rhythm
Verified
Journal Article
Closed access
KNKohki Nakamura
Kohki Nakamura
TSTakehito Sasaki
Takehito Sasaki
YTYutaka Take
Yutaka Take
KMKentaro Minami
Kentaro Minami
MIMitsuho Inoue
Mitsuho Inoue
SNShigeto Naito
Shigeto Naito

16 July 2020 in Journal of Arrhythmia
Verified
Journal Article
Open access
PDF file
TSTakehito Sasaki
Takehito Sasaki
KNKohki Nakamura
Kohki Nakamura
MIMitsuho Inoue
Mitsuho Inoue
KMKentaro Minami
Kentaro Minami
YMYuko Miki
Yuko Miki
SNShigeto Naito
Shigeto Naito
Purpose: A novel ablation catheter capable of local impedance (LI) monitoring (IntellaNav MiFi OI, Boston Scientific) has been recently introduced to clinical practice. We aimed to determine the optimal LI drops for an effective radiofrequency ablation during cavo‐tricuspid isthmus (CTI) ablation.Methods: This retrospective observational study enrolled 50 consecutive patients (68 ± 9 years; 34 males) who underwent a CTI ablation using the IntellaNav MiFi OI catheter, guided by Rhythmia. The LI at the start of radiofrequency applications (initial LI) and minimum LI during radiofrequency applications were evaluated. The absolute and percentage LI drops were defined as the difference between the initial and minimum LIs and 100× absolute LI drop/initial LI, respectively.Results: A total of 518 radiofrequency applications were analyzed. The absolute and percentage LI drops were significantly greater at effective ablation sites than ineffective sites (median, 15 ohms vs 8 ohms, P < .0001; median, 14.7% vs 8.3%, P < .0001). A receiver‐operating characteristic analysis demonstrated that at optimal cutoffs of 12 ohms and 11.6% for the absolute and percentage LI drops, the sensitivity and specificity for predicting the effectiveness of the ablation were 66.5% and 88.2%, and 65.1% and 88.2%, respectively. Finally, bidirectional conduction block along the CTI was achieved in all patients.Conclusions: During the LI‐guided CTI ablation, the effective RF ablation sites exhibited significantly greater absolute and percentage LI drops than the ineffective RF ablation sites. Absolute and percentage LI drops of 12 ohms and 11.6% may be suitable targets for effective ablation.

13 July 2021 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
KNKohki Nakamura
Kohki Nakamura
TSTakehito Sasaki
Takehito Sasaki
KMKentaro Minami
Kentaro Minami
YTYutaka Take
Yutaka Take
MIMitsuho Inoue
Mitsuho Inoue
SNShigeto Naito
Shigeto Naito

3 November 2020 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
KNKohki Nakamura
Kohki Nakamura
TSTakehito Sasaki
Takehito Sasaki
YTYutaka Take
Yutaka Take
KMKentaro Minami
Kentaro Minami
MIMitsuho Inoue
Mitsuho Inoue
SNShigeto Naito
Shigeto Naito

2 November 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
VRVivek Y Reddy
Vivek Y Reddy
MKMelissa H. Kong
Melissa H. Kong
JPJan Petru
Jan Petru
AMAbhishek Maan
Abhishek Maan
MFMoritoshi Funasako
Moritoshi Funasako
PNPetr Neuzil
Petr Neuzil
Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility. In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF. Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.