A large percentage of coronavirus disease 2019 (COVID-19) patients have taste dysfunction. Interleukin 6 (IL-6) levels in mild and moderate COVID-19 patients with the type (quantitative or qualitative) of taste disorders were compared in this observational study. The 208 COVID-19 patients (118 men and 90 women) revealing only taste dysfunctions as prodromic symptoms were classified as mild and moderate patients. Survey results were used to evaluate the taste disorder. The IL-6 levels were measured using a chemiluminescence assay. Statistical analysis was conducted using the Wilcoxon rank, Welch’s, and Mann–Whitney tests. The findings revealed that neither the presence of dysgeusia or phantogeusia nor the perception of sour and salty, differed statistically significantly between moderate and mild patients (P > 0.05). But between moderate and mild patients, there were statistically significant differences in how umami, bitter, sweet, and parageusia were perceived (P < 0.05). There was an impairment of multiple tastes up to ageusia in patients with high IL-6 levels. The findings demonstrated that parageusia and dysfunctions in umami, bitter, and sweet taste perception can be indicators of more severe forms of COVID-19.
Levels of bone turnover markers (BTM) can be measured using saliva. The aim of the present study was to determine the Biological Variability of BTM in young subjects, on serial biological salivary samples. Saliva samples of 20 apparently healthy young subjects (9 females and 11 males) have been analyzed. Samples collected using salivette with cotton swabs were obtained three times every 15 days. PTHrP; TRAcP-5b and P1NP have been assayed. The ANOVA test was used to calculate intra and interindividual variance (CVI and CVG). The individuality index (II) and reference change value (RCV) were evaluated for the clinically significant variation between two results in the same individual. CVI was highest for PTHrP and lowest for P1NP while CVG was highest for TRAcP-5b. RCV was maximum for PTHrP and minimum for P1NP. The critical difference (RCV) is of particular interest in evaluating variations in the concentrations of BMT on the salivary matrix during oral pathologies and/or dental treatments The salivary dosage of BMT during dental treatments could be fundamental to establishing establish the timing of the treatment and, in the case of orthodontic treatments, to evaluate the effectiveness of the applied forces.
Background: The aim of this study was to evaluate the changes in platelet indices (PLT) provided by the ADVIA 2120 hematology analyzer (Siemens Hematology System) in the early stages of onset of infections and acute coronary syndromes (ACSs). Methods: Samples were selected from 40 patients admitted to the intensive care unit with suspected uncomplicated sepsis at presentation, from 40 patients with a biochemical diagnosis of ACS at presentation and from 40 apparently healthy subjects. These samples were tested for PLT and PLT indices [mean platelet volume (MPV); mean platelet mass (MPM); mean platelet component (MPC); immature platelets (RtcPlts)] obtained by automation with the ADVIA 2120 and specific biomarkers for sepsis [white blood cells (WBCs); neutrophil granulocytes (NGs); presepsin (PSP); procalcitonin (Pct); C-reactive protein (CRP)] and for SCA (hs cTnI). Results: Platelet indices (RtcPlts, MPV, MPM) were significantly altered (p > 0.005) in patients with suspected sepsis and patients with ACS compared to control subjects; however, no statistically significant difference was observed between the two groups of patients with disease. Cutoff values (ROC curves) were obtained for platelet indices that best discriminated healthy subjects from subjects with severe infection or ACS. Conclusions: Our data show that, in subjects with suspected sepsis and ACS at disease onset, a state of early platelet activation exists that is not disease-specific. Immature platelets (RtcPlts) and the platelet indices MPM and MPV, provided by the ADVIA 2120 hematology analyzer, showed high sensitivity in subjects with suspected sepsis or ACS at disease onset.
Aim of the study: We evaluated and compared blood gas analysis (EGA) non-conformities (NC) considered operator-dependent performed in Point-Of-Care (POC) analyzer as quality indicators (IQ) of the pre-analytical phase. To this end, four different NC registered in the resuscitation departments of the Hospital Polyclinic Bari from the beginning of the pandemic (March 2020) until February 2022 were evaluated. The results obtained were compared with those recorded in the pre-COVID period (March 2018–February 2020) to check if there were differences in number and type. Material and methods: GEM 4000 series blood gas analyzers (Instrumentation Laboratory, Bedford, MA, United States) are installed with integrated Intelligent Quality Management (iQM®), which automatically identify and log pre-analytical errors. All blood gas analyzers are connected to the company intranet and interfaced with the GEM Web Plus (Werfen Instrumentation Laboratory, Bedford, MA, United States) data management information system, which allows the core laboratory to remotely supervise all decentralized POC stations. The operator-dependent process NC were expressed in terms of absolute and relative proportions (percentiles and percentage changes). For performance evaluation, the Mann–Whitney U test, Chi-squared test and Six-Sigma Metric calculation for performance classification were performed. Results: In the COVID period, 31,364 blood gas tests were performed vs. 16,632 tests in the pre-COVID period. The NC related to the suitability of the EGA sample and manageable by the operators were totals of 652 (3.9%) and 749 (2.4%), respectively, in the pre-COVID and COVID periods. The pre-analytical phase IQs used did not show statistically significant differences in the two periods evaluated. The Sigma evaluation did not show an increase in error rates. Conclusions: Considering the increase in the number of EGAs performed in the two periods, the training procedures performed by the core laboratory staff were effective; the clinical users of the POC complied with the indications and procedures shared with the core laboratory without increasing the operator-dependent NCs. Furthermore, the core laboratory developed monitoring activities capable of guaranteeing the maintenance of the pre-analytical quality.