Purpose: To determine the efficacy of hearing protector insertion by comparing attenuation values measured by objective (MIRE) and subjective (REAT) methods in groups with and without training. Methods: The study included 80 male subjects assigned to experimental (with training) and control (without training) groups. The following procedures were performed: occupational history, objective and subjective assessment of hearing protectors. Only subjects in the experimental group received training and guidance on proper hearing protector insertion. Results: Attenuation values were significantly higher in the experimental group than in the control group at all frequencies (500, 1000, 2000, and 4000 Hz) investigated through the objective (MIRE) and subjective (REAT) methods. In addition, attenuation values in the control group were lower than those provided by the hearing protector manufacturer. Conclusion: Both objective and subjective attenuation tests demonstrated the efficacy of training on insertion of hearing protectors because the group that received training on proper hearing protection insertion exhibited higher attenuation values than the untrained group.
1 March 2011 in Jornal da Sociedade Brasileira de Fonoaudiologia
OBJETIVO: Verificar a efetividade de uma ação educativa de treinamento, com ênfase na importância da proteção auditiva, para trabalhadores expostos a ruído ocupacional. MÉTODOS: Participaram 78 funcionários do gênero masculino. Todos os indivíduos passaram por avaliação audiológica completa e responderam a um questionário no momento do início do atendimento. Para a segunda aplicação do questionário, os participantes foram randomicamente divididos em dois grupos: Grupo Pesquisa, constituído por 44 funcionários, que responderam ao questionário após passarem por treinamento educativo, e Grupo Controle, constituído por 34 funcionários, que responderem ao questionário antes de passar por treinamento educativo. O treinamento foi feito com base em material gráfico com figuras e textos, sob a forma de conversa. Os temas abordados foram: importância da audição, efeitos do ruído sobre a saúde, importância da prevenção da perda auditiva e da utilização do protetor auditivo, conservação e higienização dos protetores, níveis de ruído no ambiente de trabalho e atenuação do ruído fornecida pelos protetores auditivos. O questionário continha 14 perguntas de múltipla escolha que abordavam os mesmos temas explorados no treinamento educativo. RESULTADOS: Houve aumento significativo do número de acertos durante a 2ª aplicação do questionário, somente para o Grupo Pesquisa, em todas as comparações realizadas. CONCLUSÃO: Ações educativas realizadas com trabalhadores expostos a ruído ocupacional são efetivas. Além disso, o questionário é uma ferramenta estável e viável para a verificação da efetividade de programas educativos
20 February 2020 in WORK: A Journal of Prevention, Assessment & Rehabilitation
BACKGROUND: Discrepancies between attenuation obtained in the laboratory and the field are caused by several factors associated with hearing protection devices (HPDs). The effects of some factors can be minimized with proper training provided to HPD
RESUMO Objetivo Avaliar a eficácia da atenuação de um protetor auditivo em uma situação real de trabalho utilizando o método f-Microphone-in-real-ear (f-MIRE). Métodos Participaram 18 indivíduos, de ambos os gêneros (média de idade 47,17±8 anos). No local de trabalho, foi realizada a avaliação do nível pessoal de atenuação do Protetor Auditivo (PA) pelo método Field Microphone-in-Real-Ear (f-MIRE), seguido por orientações sobre a importância do uso do PA, higienização, armazenamento e treinamento para sua colocação efetiva. Resultados As análises mostraram que houve atenuação estatisticamente significante para todos os dados coletados (ruído total, por banda de frequência e dose) quando comparados os níveis de ruído no microfone lapela e no microfone sonda. Na comparação entre os valores de atenuação fornecidos pelo fabricante e os encontrados neste estudo, observou-se valores maiores para o fabricante em todas as bandas de frequência. Não houve diferença para os níveis de ruído nas diferentes atividades e horários avaliados. Conclusão Os achados do presente estudo possibilitaram conhecer o nível pessoal de atenuação do protetor auditivo durante uma situação real de trabalho, que estava dentro dos limites de tolerância. Também foi possível coletar informações sobre o ruído do ambiente em que esses trabalhadores estão expostos, onde observamos situações nas quais esse nível ultrapassava os valores de segurança, sendo assim recomendável o uso do PA. É importante que mais estudos sejam realizados utilizando o método f-MIRE, pois pode ser um aliado para avaliar a eficácia da atenuação do PA no local de trabalho.
27 February 2021 in International Journal of Occupational Safety and Ergonomics
Objectives. This study aimed to compare speech intelligibility in noise with and without hearing protection devices (HPDs). Methods. Fifty-one workers were distributed into three groups: noise-induced hearing loss group (NIHLG), normally hearing noise-exposed group (NG) and normally hearing non-exposed to noise group (CG). A free field system was used to emit monosyllables (65, 70 and 75 dB) and pink noise in different signal-to-noise ratios (SNRs) (0, −5, −10 and −15). Results. In situations with HPDs, all groups showed a decrease in the percentage of correct responses with an increase in noise level. The HPD had little effect on speech intelligibility in the NIHLG and NG. Considering the effect caused by the HPD on speech intelligibility, it was observed that the group with the greatest loss was the CG for SNRs of −5, −10 and −15. Conclusion. Although speech intelligibility is influenced by the hearing threshold, the noise level and SNR are crucial for good speech intelligibility, either with or without an HPD. It is highlighted that the NG had worse results when compared with the CG, which may indicate changes in the auditory pathway resulting from continuous noise exposure, even in the absence of changes in the audiometric thresholds.
22 June 2020 in Journal of Speech, Language, and Hearing Research
Purpose: The aims of this study were to characterize hearing symptoms, habits, and sound pressure levels (SPLs) of personal audio system (PAS) used by young adults; estimate the risk of developing hearing loss and assess whether instructions given to users led to behavioral changes; and propose recommendations for PAS users. Method: A cross-sectional study was performed in 50 subjects with normal hearing. Procedures included questionnaire and measurement of PAS SPLs (real ear and manikin) through the users' own headphones and devices while they listened to four songs. After 1 year, 30 subjects answered questions about their usage habits. For the statistical analysis, one-way analysis of variance, Tukey's post hoc test, Lin and Spearman coefficients, the chi-square test, and logistic regression were used. Results: Most subjects listened to music every day, usually in noisy environments. Sixty percent of the subjects reported hearing symptoms after using a PAS. Substantial variability in the equivalent music listening level (Leq) was noted ( M = 84.7 dBA; min = 65.1 dBA, max = 97.5 dBA). A significant difference was found only in the 4-kHz band when comparing the real-ear and manikin techniques. Based on the Leq, 38% of the individuals exceeded the maximum daily time allowance. Comparison of the subjects according to the maximum allowed daily exposure time revealed a higher number of hearing complaints from people with greater exposure. After 1 year, 43% of the subjects reduced their usage time, and 70% reduced the volume. A volume not exceeding 80% was recommended, and at this volume, the maximum usage time should be 160 min. Conclusions: The habit of listening to music at high intensities on a daily basis seems to cause hearing symptoms, even in individuals with normal hearing. The real-ear and manikin techniques produced similar results. Providing instructions on this topic combined with measuring PAS SPLs may be an appropriate strategy for raising the awareness of people who are at risk. Supplemental Material: https://doi.org/10.23641/asha.12431435