Binh Tran

Dr. Binh Tran

Department of Biomedical Engineering, The Catholic University of America, Washington DC, United States

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2015 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
QHQuoc T. Huynh
Quoc T. Huynh
UNUyen D. Nguyen
Uyen D. Nguyen
LILucia B. Irazabal
Lucia B. Irazabal
NGNazanin Ghassemian
Nazanin Ghassemian
Binh TranBinh Tran
Binh Tran
Falling is a common and significant cause of injury in elderly adults (>65 yrs old), often leading to disability and death. In the USA, one in three of the elderly suffers from fall injuries annually. This study’s purpose is to develop, optimize, and assess the efficacy of a falls detection algorithm based upon a wireless, wearable sensor system (WSS) comprised of a 3-axis accelerometer and gyroscope. For this study, the WSS is placed at the chest center to collect real-time motion data of various simulated daily activities (i.e., walking, running, stepping, and falling). Tests were conducted on 36 human subjects with a total of 702 different movements collected in a laboratory setting. Half of the dataset was used for development of the fall detection algorithm including investigations of critical sensor thresholds and the remaining dataset was used for assessment of algorithm sensitivity and specificity. Experimental results show that the algorithm detects falls compared to other daily movements with a sensitivity and specificity of 96.3% and 96.2%, respectively. The addition of gyroscope information enhances sensitivity dramatically from results in the literature as angular velocity changes provide further delineation of a fall event from other activities that may also experience high acceleration peaks.

31 August 2004 in OJIN: The Online Journal of Issues in Nursing
Verified
Journal Article
Closed access
KBKathleen Buckley
Kathleen Buckley
Binh TranBinh Tran
Binh Tran
CPCheryl Prandoni
Cheryl Prandoni
This descriptive study identified factors that influenced the receptiveness, use and acceptance of telehealth videophones by 21 family caregivers of stroke patients in the home setting. Potential obstacles to the receptiveness towards videophones included concerns by the caregiver about maintaining home security, limited need for health care support, very low or high degree of burden in caregiving, and discomfort or disinterest in using technology. Identification of possible impediments to the use of videophones is vital prior to developing and evaluating programs using telehealth as a method of rehabilitative technology.

8 January 2021 in Signals
Verified
Journal Article
Open access
PDF file
QHQuoc Huynh
Quoc Huynh
Binh TranBinh Tran
Binh Tran
Fall events in elderly populations often result in serious injury and may lead to long-term disability and/or death. While many fall detection systems have been developed using wearable sensors to distinguish falls from other daily activities, detection sensitivity and specificity decreases when exposed to more rigorous activities such as running and jumping. This research uses time-frequency analysis of accelerometer-only activity data to develop a strategy for improving fall detection accuracy. In this study, a wireless sensor system (WSS) consisting of a three-axis accelerometer, microprocessor and wireless communications module is used to collect daily activities performed following a script in the laboratory setting. Experiments were conducted on 36 healthy human subjects performing four types of falls (i.e., forward, backward, and left/right sideway falls) as well as normal movements such as standing, walking, stand-to-sit, sit-to-stand, stepping, running and jumping. In total, 1227 different activities were collected and analyzed. The developed algorithm computes the magnitude of three-axis accelerometer data to detect if a critical fall threshold is passed, then analyzes the power spectral density within a critical fall duration window (500 ms) to differentiate fall events from other rigorous activities. Fall events were observed with high energy in the 2–3.5 Hz range and distinct from other rigorous activities such as running (3.5–5.5 Hz) and jumping (1–2 Hz). Preliminary results indicate the power spectral density (PSD)-based algorithm can detect falls with high sensitivity (98.4%) and specificity (98.6%) using lab-based daily activity data. The proposed algorithm has the benefit of improved accuracy over existing time-domain only strategies and multisensor strategies.

1 September 2009
Verified
Conference Paper
Closed access
Binh TranBinh Tran
Binh Tran
KBKathleen M. Buckley
Kathleen M. Buckley
EBElizabeth M. Bertera
Elizabeth M. Bertera
PGPedro L. Gonzales
Pedro L. Gonzales
This paper provides a detailed discussion regarding the attitudes, benefits, and barriers to adoption of health IT for low income, minority, elderly populations in a community-based affordable housing setting. Results show that despite challenges to adoption of technology amongst minority populations, senior residents will adopt technology if they understand the benefits of these technologies for improving their health and for remaining independent, thereby enabling them to age-in-place.


3 February 2007 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
Binh TranBinh Tran
Binh Tran
KBK.M. Buckley
K.M. Buckley
CPC. Prandoni
C. Prandoni
Trends related to rapidly aging populations nationally and internationally, combined with shortages in skilled health professionals and rising health care costs have necessitated efficient and cost-effective technologies for improved access to health care services. This paper discusses the use of low-bandwidth telephonic technology for providing nursing and counseling services to stroke caregivers in urban and rural areas and addresses factors that affect adoption and utilization of technologies for their intended use. Twenty-one subjects with recent stroke and their caregivers and five nurses were enrolled in the study. Seventy-two telehealth visits (i.e. tele-visits) were made to urban and rural locations using standard plain-old-telephone-service (POTS). Eighty-three percent of televists experienced first-time completion success at a bandwidth of 27.6+3 kbps. Over one-third (36%) of visits were unsolicited and initiated by caregivers using the protocol. Each tele-visit lasted approximately 20 minutes. Televisit sessions ranged from providing health care instruction for caregivers to stroke-related education to caregiver counseling. Televists were widely accepted by stroke subjects and caregivers. Acceptance and utilization of telehealth services correlated with rapport between at-home users and nurses.