zifu Shi

Mr. zifu Shi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
PLPei Li
Pei Li
TBTing Bao
Ting Bao
JGJian Guan
Jian Guan
ZSzifu Shi
zifu Shi
ZXZengxiao Xie
Zengxiao Xie
WZWei ZHONG
Wei ZHONG
Local over-temperature is one of the main reasons for boiler tube failures (BTF). By accurately monitoring and controlling tube wall temperature, local over-temperature can be avoided. Based on the measured flue gas parameters and numerical simulation, a method of thermal deviation calculation is proposed in this study for the on-line calculation of the tube wall temperature of boiler superheaters. The full-size three-dimensional numerical simulation was presented on the combustion in a pulverized coal-fired boiler of 1000 MW ultra-supercritical (USC) unit. A difference in the thermal deviation of the vertical direction was innovatively introduced into a segmented discrete model, and the thermal deviation condition conforming to reality was introduced into the calculation. An on-line calculation system developed based on the current calculation method was applied in a 1000 MW USC unit. The calculated local high-temperature zone was consistent with the actual over-temperature position and conformed to the law of the allowable metal temperature of the final superheater (FSH) serpentines segment. The comparison results showed that the calculated data by this method were more reflective of tube wall temperature change with boiler loads than the measured data. According to the calculated local over-temperature zone, the immediate warning response can effectively reduce the possibility of over-temperature BTF.

5 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
PLPei Li
Pei Li
KLKe Li
Ke Li
YZYonggang Zhou
Yonggang Zhou
QLQingyi Li
Qingyi Li
ZSzifu Shi
zifu Shi
WZWei ZHONG
Wei ZHONG
It is of great importance to obtain the exact location and severity of slagging deposits on the waterwall surface of an operational boiler to avoid aimless soot-blowing and reduce steam consumption. In this paper, an effective waterwall surface temperature monitoring method is proposed to determine the slagging locations. It has been noted that the temperature difference of the waterwall surface before and after soot-blowing varied with the waterwall location, with more than 80 °C covered with slag and less than 20 °C found clean. According to this, a slagging temperature index was developed to describe the severity of slagging deposits on the waterwall surface. Results indicated that the process of slagging deposit growth included four stages, with the slagging temperature fluctuating in the range of about 90–110 °C in stage III, followed by a rapid drop below 60 °C in stage IV. Furthermore, a digital image monitoring system was used to validate the slag growth process and study the relationship between deposit thickness growth and area expansion. This novel approach provides automated and accurate guidance for each soot blower around the furnace, which reduces soot-blowing steam consumption and avoids serious slagging on the waterwall surface.

18 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ZSzifu Shi
zifu Shi
PLPei Li
Pei Li
YZYonggang Zhou
Yonggang Zhou
SNSong Ni
Song Ni
The temperature of the water wall in the furnace chamber is extremely important for the daily operation of a boiler. Considering the high temperature and dusty environment in the furnace, a temperature measurement device mainly composed of four parts (armored temperature sensor, in-furnace heat-collecting block, out-furnace fixing base, and protective cannula) was designed in this study, which could be used to directly obtain the temperature of the in-furnace water-wall. Numerical simulations of temperature measurement devices with different heat-collecting block structures were carried out using the computer fluid dynamics method. After comparing the measurement accuracy and considering the practical application scenarios, the optimized heat-collecting block structure with a specific expansion gap (0.5 mm wide and 4 mm deep) was selected for practical application. Such a temperature measurement device was then applied to a 1000 MW ultra-supercritical coal-fired boiler in China, and the tested in-furnace water-wall temperature data were in good agreement with relevant research. Compared with the conventional temperature measurement device arranged outside the furnace, the in-furnace water-wall temperature-measurement device adopted in this study has a more sensitive response characteristic and can directly reflect the temperature of the water wall inside the furnace. In addition, it can also reflect the local slag formation state of the water wall and has a long service life.