Baljinder Kaur

Dr. Baljinder Kaur

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
BKBaljinder Kaur
Baljinder Kaur
Santosh KumarSantosh Kumar
Santosh Kumar
Kaushik Kumar BrajeshKaushik Kumar Brajesh
Kaushik Kumar Brajesh
Wearable sensors are pioneering devices to monitor health issues that allow the constant monitoring of physical and biological parameters. The immunity towards electromagnetic interference, miniaturization, detection of nano-volumes, integration with fiber, high sensitivity, low cost, usable in harsh environments and corrosion-resistant have made optical wearable sensor an emerging sensing technology in the recent year. This review presents the progress made in the development of novel wearable optical sensors for vital health monitoring systems. The details of different substrates, sensing platforms, and biofluids used for the detection of target molecules are discussed in detail. Wearable technologies could increase the quality of health monitoring systems at a nominal cost and enable continuous and early disease diagnosis. Various optical sensing principles, including surface-enhanced Raman scattering, colorimetric, fluorescence, plasmonic, photoplethysmography, and interferometric-based sensors, are discussed in detail for health monitoring applications. The performance of optical wearable sensors utilizing two-dimensional materials is also discussed. Future challenges associated with the development of optical wearable sensors for point-of-care applications and clinical diagnosis have been thoroughly discussed.

7 September 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BKBaljinder Kaur
Baljinder Kaur
Santosh KumarSantosh Kumar
Santosh Kumar
Kaushik Kumar BrajeshKaushik Kumar Brajesh
Kaushik Kumar Brajesh
Two-dimensional (2D) materials-based fiber-optic surface plasmon resonance (SPR) sensor is proposed to diagnose the different cancers at the wavelength of 1550 nm. In this work, five types of cancerous cell lines such as Jurkat, HeLa, PC12, MDA-MB-231, MCF7, and normal cell lines are considered for analysis. The power loss through proposed SPR sensor is maximum at a specific angle ${\theta }_{\textit {SPR}}$ . Resonance angle ${\theta }_{\textit {SPR}}$ shift to another angle for different cancerous cell lines. The angular shift and power loss of different cancerous cells are different from their normal cells due to the different refractive indices (RIs) of each cell. The proposed work is helpful in the detection of different types of cancer such as blood, cervical, Adrenal Glands and Breast Cancer by measuring the angular shift in peak power loss. For angular power loss calculations, transfer matrix method (TMM) is used. The sensor structure consists of fiber core, clad, metal layer, and 2D material layer. In 2D material, role of MoS 2 and graphene are investigated on the performance of sensor. Further, three structures such as (i) probe 1: SiO 2 -perfluorinated (PF)-Ag (ii) probe 2: SiO 2 -PF-Ag-MoS 2 , and (iii) probe 3: SiO 2 -PF-Ag-graphene are designed and investigated in detail. Calculated values of a figure of merit (FOM) for probe 2, probe 1, and probe 3 sensor structure are 6654.54 RIU −1 , 4645.21 RIU −1 , and 832.88 RIU −1 , respectively. Sensitivity and limit of detection (LoD) are also calculated from power loss spectrum. Probe 2 provides maximum FOM in all and exhibits three times larger FOM than earlier reported cancer cell sensors. The calculated LoD in case of probe 2 for Jurkat, HeLa, PC12, MDA-MB-231, MCF7 are 0.4550 −5 , 0.4510 −5 , 0.4440 −5 , 0.4350 −5 and 0.430 −5 respectively with maximum sensitivity of 232.33 deg./RIU. Thus, LoD of the proposed sensor is quite low that makes it better than most of the recently reported SPR based fiber-optic sensors. The proposed fiber optic SPR sensor with high FOM and low LoD is a suitable candidate for the early diagnosis of different types of cancers.

24 February 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BKBaljinder Kaur
Baljinder Kaur
Santosh KumarSantosh Kumar
Santosh Kumar
Kaushik Kumar BrajeshKaushik Kumar Brajesh
Kaushik Kumar Brajesh
A highly sensitive spectral surface plasmon resonance (SPR) based fiber-optic sensor is proposed to diagnose the colorectal cancer that develops in the colon or rectal of intestine. Proposed sensor consists of transition metal carbides known as MXenes having chemical formula Ti 3 C 2 $\text{T}_{X}$ based layered materials. The high sensitivity of fiber-optic sensor is attributed to high intercalation capacity, large surface area of 93.6 m 2 g −1 , hydrophilic nature, biocompatibility, good thermal stability and high electrical conductivity of two-dimensional (2D) MXenes. The performance of sensor is analyzed under wavelength interrogation method in the wavelength range of 400 nm to 1000 nm. The dependence of angular characteristics of a multimode fiber-based sensor is investigated theoretically by optimizing the resonance curves to obtain the maximum sensitivity (S) and Figure of merit (FOM). The potential of two most popular plasmonic metals gold (Au) and silver (Ag) is demonstrated to compare the performance of the sensor. The sensor design is able to differentiate between normal and cancerous colorectal state due to their obtained in case of Au-Ti 3 C 2 based sensing probe is 6854.3 nm/RIU and 45.69 RIU −1 . The sensitivities of Ag, Ag-Ti 3 C 2 F 2 , Ag-Ti 3 C 2 (OH) 2 , Ag-Ti 3 C 2 O 2 , Ag-Ti 3 C 2 based sensor are 6230.70 nm/RIU, 6308.46 nm/RIU, 6620.12 nm/RIU, 6386.31 nm/RIU and 10766.28 nm/RIU, respectively. The presence of MXenes in Ag based sensor enhances the sensitivity and FOM nearly 2 times compared to Au based sensor. Ultrahigh sensitivity of 10766.28 nm/RIU and FOM of 76.90 RIU −1 with low detection limit with Ag-Ti 3 C 2 based sensor is highest among the earlier reported fiber-optic SPR sensor for colorectal cancer detection.

1 September 2024 in APL Photonics
Verified
Journal Article
Open access
PDF file
BKBaljinder Kaur
Baljinder Kaur
Santosh KumarSantosh Kumar
Santosh Kumar
JNJan Nedoma
Jan Nedoma
RMRadek Martinek
Radek Martinek
Carlos MarquesCarlos Marques
Carlos Marques
Optical biosensors that consist of a light source, optical elements, and a photodetector are used to detect chemical and biological species and pollutants. This Tutorial discusses the fundamental details of optical biosensing techniques that include materials, working principle, components, sensor configurations, parameters, and future prospects. Optical biosensing techniques include plasmonic [surface plasmon resonance (SPR) and localized SPR], fluorescence, luminescence, Raman scattering, colorimetric, and interferometric methods. Bioreceptor elements play a significant role in detecting the specific analyte that can be synthetic or natural. Surface functionalization techniques to bind the bioreceptor elements on the surface, to control the bioreceptor orientation, have been discussed in detail. The possibility of integration of techniques on a chip, to develop wearable, implantable sensors, and the associated challenges have been fully demonstrated. This Tutorial provides valuable insights into the present state and future directions of optical biosensors for various applications.

9 October 2018 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
Anuj K. SharmaAnuj K. Sharma
Anuj K. Sharma
BKBaljinder Kaur
Baljinder Kaur
Fiber optic surface plasmon resonance (FOSPR) sensor with samarium-doped chalcogenide core, polymer clad, Ag layer, and 2D material (graphene and MoS2) monolayer is studied in near-infrared seeking sensitive and accurate determination of malignancies in human liver tissues. The analysis shows that the presence of 2D material significantly catalyzes the optimum radiation damping (ORD) in the FOSPR structure, causing massive increase in its figure of merit (FOM). At ORD, i.e., 803.9-nm wavelength (λ) and 35.7-nm Ag layer thickness (d m ), the FOM of graphene-based FOSPR sensor races to 6904.012 RIU -1 . Similarly, at λ = 1099.35 nm and d m = 29.8 nm, MoS 2 -based FOSPR sensor's FOM shoots to 5897.082 RIU -1 . The comparison reveals that the above FOM values are way better than for the existing FOSPR sensors. For biosensing, MoS 2 -based FOSPR sensor should be used, as its longer ORD wavelength (1099.35 nm) leads to reduced Rayleigh scattering and lesser photodamage of tissue. For other sensing applications, graphene-based FOSPR sensor at its ORD condition can be used.

6 January 2023 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
AKAnamika Kumari
Anamika Kumari
VVVibha Vyas
Vibha Vyas
BKBaljinder Kaur
Baljinder Kaur
Kaushik Kumar BrajeshKaushik Kumar Brajesh
Kaushik Kumar Brajesh
Santosh KumarSantosh Kumar
Santosh Kumar
In the present work, a highly sensitive prism-based surface plasmon resonance (SPR) sensor for the detection of formalin using multilayer black phosphorous (BP) is proposed. Formalin, which is widely used as a preservative, can cause a variety of diseases, making its detection crucial. The transfer matrix method is utilized to compare and analyze the proposed structures of the SPR-based prism sensor in the Kretschmann configuration. The effect of prism materials (BAK3, BK7, SF10, SF11, and 2S2G), metals (gold, silver, copper, and aluminum), and 2-D materials (graphene, MoS $_2$ , WS $_2$ , and BP) on the performance of the sensor for formalin detection has been analyzed and discussed. The analysis of the impact of employing multilayer 2-D materials is carried out. Optimization of the thickness of the 2-D material is performed to achieve a structure that gives better sensitivity. The sensitivity achieved for structures with multilayer graphene, MoS $_2$ , and WS $_2$ are 172.82 $^{\circ}$ /RIU, 195.97 $^{\circ}$ /RIU, and 218.04 $^{\circ}$ /RIU, respectively. A highly sensitive structure for formalin detection is proposed with BK7, silver, and nine layers of BP. A sensitivity of 289.4565 $^{\circ}$ /RIU and a detection accuracy (DA) of 0.3125/ $^{\circ}$ are obtained. The limit of detection of the proposed sensor for different concentrations of formalin lies in the range of 3.45–3.56 $ \mu $ RIU.