Zhijun Liang

Prof. Dr. Zhijun Liang

The Institute of High Energy Physics, Chinese Academia of Science, Beijing 100049, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in The European Physical Journal Plus
Verified
Journal Article
Closed access
PDF file
ZLZhijun Liang
Zhijun Liang
BLB. Liu
B. Liu

25 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MZMei of high energy Zhao
Mei of high energy Zhao
XJXuewei Jia
Xuewei Jia
KWKewei Wu
Kewei Wu
TYTao Yang
Tao Yang
MLMengzhao Li
Mengzhao Li
JCJoão Guimarães da Costa
João Guimarães da Costa

16 July 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MLMengzhao Li
Mengzhao Li
HCHan Cui
Han Cui
YFYunyun Fan
Yunyun Fan
DHDejun Han
Dejun Han
YHYuekun Heng
Yuekun Heng
XZXingan Zhang
Xingan Zhang
The thickness of the high-resistivity layer (active layer) is a crucial factor affecting the timing resolution of low gain avalanche diodes (LGADs). We studied the potential improvement of the timing resolution of charge particles based on LGADs with different active layer thicknesses. The Institute of High Energy Physics (IHEP) and the Novel Device Laboratory (NDL) jointly designed two types of LGAD sensors with active layer thicknesses of 33 and 50 $\mu \text{m}$ . The timing resolution is given by contributions from the time walk, jitter, and nonuniform charge deposition (Landau term). The jitter and the Landau term contributions in the timing resolution are extracted by the combination of the ${^{90}{Sr}}$ beta source test and the picosecond laser test. The Landau contribution is found to be the dominant contribution for both types of LGAD sensors, and the Landau contribution of the 33 $\mu \text{m}$ sensor is lower than that of the 50 $\mu \text{m}$ sensor. Based on the experimental results, we perform the simulation for thinner active layer LGAD with the WeightField2 program. The timing resolution can be further improved by reducing the active layer thickness from 33 to 20 $\mu \text{m}$ .

1 August 2021 in Journal of Instrumentation
Verified
Journal Article
Open access
MLM. Li
M. Li
YFY. Fan
Y. Fan
BLBohu Liu
Bohu Liu
Huan CuiHuan Cui
Huan Cui
XJX. Jia
X. Jia
GKGregor Kramberger
Gregor Kramberger

4 August 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
TZTianyuan Zhang
Tianyuan Zhang
YFYuan Feng
Yuan Feng
MLMengzhao Li
Mengzhao Li
WSWeiyi Sun
Weiyi Sun
YFYunyun Fan
Yunyun Fan
JCJoão Guimaraes da Costa
João Guimaraes da Costa

9 June 2023 in arXiv
Verified
Preprint
Open access
PDF file
WSWeiyi Sun
Weiyi Sun
YFYunyun Fan
Yunyun Fan
MZMei Zhao
Mei Zhao
HCHan Cui
Han Cui
CYChengjun Yu
Chengjun Yu
GXGaobo Xu
Gaobo Xu
Low Gain Avalanche Detectors (LGAD) for the High-Granularity Timing Detector (HGTD) are crucial in reducing pileups in the High-Luminosity Large Hadron Collider. Numerous studies have been conducted on the bulk irradiation damage of LGADs. However, few studies have been carried out on the surface irradiation damage of LGAD sensors with shallow carbon implantation. In this paper, the IHEP-IME LGADs with shallow carbon implantation were irradiated up to 2 MGy using gamma irradiation to investigate surface damage. Important characteristic parameters, including leakage currents, breakdown voltage (BV), inter-pad resistances, and capacitances, were tested before and after irradiation. The results showed that the leakage current and BV increased after irradiation, whereas overall inter-pad resistance exhibited minimal change and remained above $10^9\ Ω$ before and after irradiation. Capacitance was found to be less than 4.5 pF with a slight decrease in the gain layer depletion voltage (V$_{gl}$) after irradiation. No parameter affected by the inter-pad separation was observed before and after irradiation. All characteristic parameters meet the requirements of HGTD, and this design can be used to further optimization.