Mei of high energy Zhao

Dr. Mei of high energy Zhao

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MZMei of high energy Zhao
Mei of high energy Zhao
XJXuewei Jia
Xuewei Jia
KWKewei Wu
Kewei Wu
TYTao Yang
Tao Yang
MLMengzhao Li
Mengzhao Li
JCJoão Guimarães da Costa
João Guimarães da Costa

28 December 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
YTYuhang Tan
Yuhang Tan
TYTao Yang
Tao Yang
KLKai Liu
Kai Liu
CWCongcong Wang
Congcong Wang
XZXiyuan Zhang
Xiyuan Zhang
Xin ShiXin Shi
Xin Shi
To meet the high radiation challenge for detectors in future high-energy physics, a novel 3D 4H-SiC detector was investigated. Three-dimensional 4H-SiC detectors could potentially operate in a harsh radiation and room-temperature environment because of its high thermal conductivity and high atomic displacement threshold energy. Its 3D structure, which decouples the thickness and the distance between electrodes, further improves the timing performance and the radiation hardness of the detector. We developed a simulation software—RASER (RAdiation SEmiconductoR)—to simulate the time resolution of planar and 3D 4H-SiC detectors with different parameters and structures, and the reliability of the software was verified by comparing the simulated and measured time-resolution results of the same detector. The rough time resolution of the 3D 4H-SiC detector was estimated, and the simulation parameters could be used as guideline to 3D 4H-SiC detector design and optimization.

23 June 2023 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
MLMengzhao Li
Mengzhao Li
WSWeiyi Sun
Weiyi Sun
ZLZhijun Liang
Zhijun Liang
MZMei of high energy Zhao
Mei of high energy Zhao
XZXiaoxu Zhang
Xiaoxu Zhang
Gaobo XuGaobo Xu
Gaobo Xu
AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP) designed a large-size AC-LGAD with a pitch of 2000 μm and AC pad of 1000 μm, and explored the effect of N+ layer dose on the spatial resolution and time resolution. The spatial resolution varied from 36 μm to 16 μm depending on N+ dose for a charge corresponding to about 12 minimum ionizing particles. The jitter component of the time resolution does not change significantly with different N+ doses, and it is about 15-17 ps measured by laser. The AC-LGAD with a low N+ dose has a large attenuation factor and better spatial resolution in the central region between pads. In these specific conditions, large signal attenuation factor and low noise level are beneficial to improve the spatial resolution of the AC-LGAD sensor.

14 October 2024 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
KLKang Liu
Kang Liu
MLMeng-Zhao Li
Meng-Zhao Li
JZJun-Hua Zhang
Jun-Hua Zhang
WSWei-Yi Sun
Wei-Yi Sun
YFYun-Yun Fan
Yun-Yun Fan
KLKun Liu
Kun Liu

1 June 2013 in Journal of Semiconductors
Verified
Journal Article
Closed access
PDF file
MZMei of high energy Zhao
Mei of high energy Zhao
RLRenrong Liang
Renrong Liang
JWJing Wang
Jing Wang
Jun XuJun Xu
Jun Xu

1 September 2022 in Journal of Instrumentation
Verified
Journal Article
Closed access
XZX. Zhang
X. Zhang
MZMei of high energy Zhao
Mei of high energy Zhao
LZL. Zhang
L. Zhang
TYT. Yang
T. Yang
JCJ. Guimarães da Costa
J. Guimarães da Costa
XJX. Jia
X. Jia
AC-Coupled Low Gain Avalanche Diodes (AC-LGADs) are a new type of silicon sensors which conceived for experiments at future colliders. As an evolution of the standard Low Gain Avalanche Diodes (LGADs), AC-LGADs have similar fast timing performance. The innovation is that AC-LGADs are available to provide fine temporal and spatial resolution simultaneously, thanks to two key features: AC-coupled readout through the dielectric layer and a continuous resistive n+ implant. The Institute of High Energy Physics (IHEP) High-Granularity Timing Detector group is developing its first version of AC-LGAD sensors. This paper present the impact of following parameters on AC-LGAD sensor performance: n+ dose, dielectric material and thickness, pad/pitch ratio and the distance between pad and cathode. All data are obtained from 2D Technology Computer-Aided Design (TCAD) simulations. The simulations will benefit future design and optimization.