Xu Jin

Dr. Xu Jin


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Microorganisms
Verified
Journal Article
Open access
PDF file
XFXuebin Feng
Xuebin Feng
MZMengyu Zhu
Mengyu Zhu
XJXu Jin
Xu Jin
WYWenqing Yin
Wenqing Yin
FHFei Hu
Fei Hu
This article studies the sterilization effects of high-voltage pulsed electric field (PEF) of technology on filamentous fungi. A cell dielectric model was proposed based on the physical structure of filamentous fungi. Basic theories of the electromagnetic field were comprehensively applied, and the multiphysics field simulation software COMSOL Multiphysics was used for more detailed study. The effects of PEF treatment parameters and microbial characteristic parameters on the resulting cell membrane and nuclear membrane changes were simulated and analyzed. The results showed significant effects on the transmembrane voltage of the cell membrane and nuclear membrane from the electric field intensity, pulse duration, cell membrane thickness, superposition effect of the pulses. However, the amount of hyphae had little effect, and the number of cell nuclei and the thickness of the cell walls had almost no effect on the transmembrane voltage of the cell membranes and the nuclear membranes. The results provide theoretical support for applying high-voltage PEFs to kill fungi in practical applications.

17 November 2017 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
XJXu Jin
Xu Jin
LLLiu Le
Liu Le
YPYu Pude
Yu Pude

18 September 2019 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
YCYang Cui
Yang Cui
XJXu Jin
Xu Jin
YXYuhui Xu
Yuhui Xu
HSHengqi Shui
Hengqi Shui

20 June 2023 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
XZXiche Zhang
Xiche Zhang
XJXu Jin
Xu Jin

1 July 2020 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
KXKe Xie
Ke Xie
XJXu Jin
Xu Jin
ZPZhongwei Pan
Zhongwei Pan

26 September 2019 in Biology
Verified
Journal Article
Open access
PDF file
XFXuebin Feng
Xuebin Feng
PHPeijun He
Peijun He
CPChaoya Pan
Chaoya Pan
XJXu Jin
Xu Jin
BXBaoshan Xue
Baoshan Xue
Yan QianYan Qian
Yan Qian
This paper adopts the Design-Expert software to design an orthogonal experiment with a pulse voltage amplitude of 30 kV, processing time of three minutes, and a pulse width of 45 μs as the center points, in order to study the effects of the pulsed electric field on the cell wall and infection activity of Rhizoctonia solani. High-voltage pulse power was used to treat the bacteria solution with the pulsed electric field. Untreated Rhizoctonia solani were used as the control group. Transmission electron microscope images were used to analyze the cell wall damage. ANOVA was performed on the experimental results and the fitting degree of the model was good (F>>1). Response surface analysis was used to optimize the parameters based on chitin content and polygalacturonase activity. The optimal treatment conditions were obtained as a pulse voltage amplitude of 25 kV, processing time of 2.54 min, and a pulse width of 34.35 μs. On this basis, experiments were designed to verify the optimized conditions. The results demonstrated that, under the optimal processing conditions, the damage index of the cell wall of Rhizoctonia solani was 9.59% lower in chitin content and 83.05% lower in polygalacturonase activity compared with those of the control group. All indexes were significantly different (P < 0.001), which is consistent with the parameter optimization results. The results provide a theoretical basis for the pulsed electric field assisted sterilization and reference for the design of plant protection machinery in the latter stage.