Schistosomiasis is a neglected tropical disease despite of being a major public health problem affecting nearly 240 million people in the world. Due to the migratory flow from endemic countries to Western countries, an increasing number of cases is being diagnosed in non-endemic areas, generally in migrants or people visiting these areas. Serology is the recommended method for screening and diagnosis of schistosomiasis in migrants from endemic regions. However, serological techniques have a highly variable sensitivity. The aim of this study was to evaluate retrospectively the sensitivity of three different serological tests used in real clinical practice for the screening and diagnosis of imported schistosomiasis in sub-Saharan migrant patients, using the detection of schistosome eggs in urine, faeces or tissues as the gold standard. We evaluated three different serological techniques in 405 sub-Saharan patients with confirmed schistosomiasis treated between 2004 and 2022: an enzyme-linked immunosorbent assay (ELISA), an indirect haemagglutination assay (IHA) and an immunochromatographic test (ICT). The overall sensitivity values obtained with the different techniques were: 44.4% for IHA, 71.2% for ELISA and 94.7% for ICT, respectively. According to species, ICT showed the highest sensitivity (S. haematobium: 94%, S. mansoni: 93.3%; and S. intercalatum/guineensis: 100%). In conclusion, our study shows that Schistosoma ICT has the best performance in real clinical practice, when compared to ELISA and IHA, in both S. mansoni and S. haematobium infections.
Migratory flows and international travel are triggering an increase in imported cases of schistosomiasis in non-endemic countries. The present study aims to evaluate the effectiveness of the LAMP technique on patients’ urine samples for the diagnosis of imported schistosomiasis in a non-endemic area in comparison to a commercial immunochromatographic test and microscopic examination of feces and urine. A prospective observational study was conducted in sub-Saharan migrants attending the Tropical Medicine Unit, Almería, Spain. For schistosomiasis diagnosis, serum samples were tested using an immunochromatographic test (Schistosoma ICT IgG-IgM). Stool and urine samples were examined by microcopy. Urine samples were evaluated by combining three LAMP assays for the specific detection of Schistosoma mansoni, S. haematobium, and for the genus Schistosoma. To evaluate the diagnostic accuracy, a latent class analysis (LCA) was performed. In total, 115 patients were included (92.2% male; median age: 28.3 years). Of these, 21 patients (18.3%) were diagnosed with schistosomiasis confirmed by microscopy, with S. haematobium being the most frequent species identified (18/115; 15.7%). The Schistosoma ICT IgG-IgM test result was 100% positive and Schistosoma-LAMP was 61.9% positive, reaching as high as 72.2% for S. haematobium. The sensitivity and specificity estimated by LCA, respectively, were: 92% and 76% for Schistosoma ICT IgG-IgM, 68% and 44% for Schistosoma-LAMP, and 46% and 97% for microscopy. In conclusion, the Schistosoma-LAMP technique presented a higher sensitivity than microscopy for the diagnosis of imported urinary schistosomiasis, which could improve the diagnosis of active infection, both in referral centers and in centers with limited experience or scarce resources and infrastructure.
Migratory flows and international travel are triggering an increase in imported cases of schistosomiasis in non-endemic countries, with serology being the recommended method for screening migrants. The present study aims to evaluate, for the first time, the LAMP technique on patients’ urine samples for the diagnosis of imported schistosomiasis in a non-endemic area in comparison to a commercial immunochromatographic test and microscopic examination of feces and urine. A prospective observational study was conducted in sub-Saharan migrants attending at the Tropical Medicine Unit, Almería, Spain. For schistosomiasis diagnosis, serum samples were tested using an immunochromatographic test (Schistosoma ICT IgG-IgM). Stool and urine samples were examined by microcopy. Urine samples were evaluated by combining three LAMP assays for the specific detection of Schistosoma mansoni and S. haematobium, and an assay for the genus Schistosoma. To evaluate the diagnostic accuracy of Schistosoma-LAMP in comparison to microscopy and Schistosoma ICT IgG-IgM test, a Latent Class Analysis (LCA) was performed. A total of 115 patients were included; 21 patients (18.3%) were diagnosed with schistosomiasis confirmed by microscopy, with S. haematobium being the most frequent species identified (18/115; 15.7%). The Schistosoma ICT IgG-IgM test resulted 100% positive and Schistosoma-LAMP was 61.9% positive, reaching as high as 72.2% for S. haematobium. The sensitivity and specificity estimated by LCA, respectively, were: 92% and 76% for Schistosoma ICT IgG-IgM, 68% and 44% for Schistosoma-LAMP and, 46% and 97% for microscopy. The Schistosoma-LAMP technique presented a higher sensitivity than microscopy for the diagnosis of imported urinary schistosomiasis, which could improve the diagnosis both in referral centers and in centers with limited experience or scarce resources and infrastructure.
Introduction ISMiHealth is a clinical decision support system, integrated as a software tool in the electronic health record system of primary care, that aims to improve the screening performance on infectious diseases and female genital mutilation (FGM) in migrants. The aim of this study is to assess the health impact of the tool and to perform a process evaluation of its feasibility and acceptability when implemented in primary care in Catalonia (Spain). Methods and analysis This study is a cluster randomised control trial where 35 primary care centres in Catalonia, Spain will be allocated into one of the two groups: intervention and control. The health professionals in the intervention centres will receive prompts, through the ISMiHealth software, with screening recommendations for infectious diseases and FGM targeting the migrant population based on an individualised risk assessment. Health professionals of the control centres will follow the current routine practice. A difference in differences analysis of the diagnostic rates for all aggregated infections and each individual condition between the intervention and control centres will be performed. Mixed-effects logistic regression models will be carried out to identify associations between the screening coverage and predictor factors. In addition, a process evaluation will be carried out using mixed methodology. Ethics and dissemination The study protocol has been approved by the institutional review boards at Hospital Clínic (16 June 2022, HCB/2022/0363), Clinical Research Ethics Committee of the Primary Care Research Institute IDIAPJGol (22 June 2022, 22/113-P) and the Almería Research Ethics Committee (27 July 2022, EMC/apg). The study will follow the tenets of the Declaration of Helsinki and Good Clinical Practice. All researchers and associates signed a collaboration agreement in which they undertake to abide by good clinical practice standards. Findings will be disseminated in peer-reviewed journals and communications to congresses. Trial registration number NCT05868005.