Ertugrul Sahin

Dr. Ertugrul Sahin

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Turkish Neurosurgery
Verified
Journal Article
Closed access
ESErtugrul Sahin
Ertugrul Sahin
YEYener Erken
Yener Erken
AIM: To design a practical, low-cost, and freely mobile training model for biportal endoscopic spine surgery to improve the surgeons' abilities in basic endoscopic skills, including triangulation, two-dimensional visualization, and one-handed control of the instruments.MATERIAL and METHODS: The training model involved three stages: triangulation, drilling, and punching. It was composed of sawbones covered by solid and impenetrable materials (a cardboard box was used), monitor (laptop or mobile phone), and hand tools, including an ear endoscope cameras for mobile phone and laptop, Dremel (R) style + rotary tool at 22000 rpm, Dremel (R) 2.0-mm diamond wheel point burr, Kerrison punch, No.11 blade, 18 G spinal needle, and mobile phone holder.RESULTS: The model was set up with easily accessible materials and could be performed everywhere. It can also be used to perform laminotomy on sawbones using a high-speed diamond burr and Kerrison punch under a two-dimensional endoscopic view.CONCLUSION: The training model can be useful in improving the endoscopic skills of all spine surgeons, particularly neurosurgeons and those who have little to no experience in endoscopic procedures. Additionally, it can provide familiarity on two-dimensional endoscopic views and triangulation.

1 January 2022 in Spine Surgery and Related Research
Verified
Journal Article
Open access
PDF file
ESErtugrul Sahin
Ertugrul Sahin
HBHaluk Berk
Haluk Berk
SOSermin Ozkal
Sermin Ozkal
PKPembe Keskinoglu
Pembe Keskinoglu
PBPinar Balci
Pinar Balci
ABAli Balci
Ali Balci
Introduction: The use of the antifibrinolytic agent tranexamic acid has positive effects on bleeding control, but our knowledge is still limited regarding how fibrinolysis suppression changes the process of bone formation and the quality of bone. Because of the several side effects of systemic tranexamic acid, topical usage has been established in several procedures. This study aimed to investigate the effect of local tranexamic acid on vertebral fusion by using macroscopic, radiologic, and microscopic techniques. We also attempted to determine the safe dose range in case some doses had negative effects on fusion. Methods: Twenty-eight Wistar albino rats underwent intertransverse fusion. All rats were randomized into four groups: groups treated with local tranexamic acid doses of 1 mg/kg (D1), 10 mg/kg (D10), and 100 mg/kg (D100) and the control group with no drug (D0). At the end of the eighth week, all rats were sacrificed for evaluation in terms of palpation, mammography, and histopathologic analysis. Results: The manual palpation results presented with lower fusion rates in D10 and D100 groups than in the control group. Radiological examination results were significantly higher in the control group. The histopathologic examination re-vealed no significant differences between groups in the percent of new bone formation. Conclusions: Our results showed that local administration of tranexamic acid reduced the quality and stability of fusion without a delay in bone formation. However, doses of 1 mg/kg did not reduce the stability in the palpation test. Our find-ings suggest that 1 mg/kg dose is a critical threshold above which tranexamic acid reduced the bone healing process of fusion and that surgeons should consider the doses of local tranexamic acid during surgery.

1 February 2023 in Journal of Surgery and Medicine
Verified
Journal Article
Open access
PDF file
ESErtugrul Sahin
Ertugrul Sahin
HBHaluk Berk
Haluk Berk
Background/Aim: There is a lack of understanding of artificial intelligence (AI) among orthopedic surgeons regarding how it can be used in their clinical practices. This study aimed to evaluate the attitudes of orthopedic surgeons regarding the application of AI in their practices. Methods: A cross-sectional study was conducted in Turkey among 189 orthopedic surgeons between November 2021 and February 2022. An electronic survey was designed using the SurveyMonkey platform. The questionnaire included six subsections related to AI usefulness in clinical practice and participants’ knowledge about the topic. It also surveyed their acceptance level of learning, concerns about the potential risks of AI, and implementation of this technology into their daily practice Results: A total of 33.9% of the participants indicated that they were familiar with the concept of AI, while 82.5% planned to learn about artificial intelligence in the coming years. Most of the surgeons (68.3%) reported not using AI in their daily practice. The activities of orthopedic associations focused on AI were insufficient according to 77.2% of participants. Orthopedic surgeons expressed concern over AI involvement in the future regarding an insensitive and nonempathic attitude toward the patient (53.5%). A majority of respondents (80.4%) indicated that AI was most feasible in extremity reconstruction. Pelvis fractures were found in the region where the AI system is most needed in the fracture classification (68.7%). Conclusion: Most of the respondents did not use AI in their daily clinical practice; however, almost all surgeons had plans to learn about artificial intelligence in the future. There was a need to improve orthopedic associations’ activities focusing on artificial intelligence. Furthermore, new research including the medical ethics issues of the field will be needed to allay the surgeons’ worries. The classification system of pelvic fractures and sub-branches of orthopedic extremity reconstruction were the most feasible areas for AI systems. We believe that this study will serve as a guide for all branches of orthopedic medicine. '+st+' Department of Orthopedics and Traumatology Cabitza F, Locoro A, Banfi G. Machine learning in orthopedics: A literature review. Front Bioeng Biotechnol. 2018;6:75. DOI: https://doi.org/10.3389/fbioe.2018.00075 Choy G, Khalilzadeh O, Michalski M, Do S, Samir AE, Piankh OS, et al. Current applications and future impact of machine learning in radiology. Radiology. 2018;288(2):318–28. DOI: https://doi.org/10.1148/radiol.2018171820 Panchmatia JR, Visenio MR, Panch T. The role of artificial intelligence in orthopedic surgery. Br J Hosp Med. 2018;79(12):676–81. DOI: https://doi.org/10.12968/hmed.2018.79.12.676 Federer SJ, Jones GG. Artificial intelligence in orthopedics: A scoping review. PLoS ONE. 2021;16(11):e0260471. doi: 10.1371/journal.pone.0260471. Urakawa T, Tanaka Y, Goto S, Matsuzawa H, Watanabe K, Endo N. Detecting intertrochanteric hip fractures with orthopedist-level accuracy using a deep convolutional neural network. Skelet Radiol. 2019;48:239–44. DOI: https://doi.org/10.1007/s00256-018-3016-3 Yamada Y, Maki S, Kishida S, Nagai H, Arima J, Yamakawa N, et al. Automated classification of hip fractures using deep convolutional neural networks with orthopedic surgeon-level accuracy: ensemble decision-making with antero-posterior and lateral radiographs. Acta Orthop. 2020;91:699–704. DOI: https://doi.org/10.1080/17453674.2020.1803664 Choi JW, Cho YJ, Lee S, Lee J, Lee S, Choi YH, et al. Using a dual-input convolutional neural network for automated detection of pediatric supracondylar fracture on conventional radiography. Investig Radiol. 2020;55:101–10. DOI: https://doi.org/10.1097/RLI.0000000000000615 Rouzrokh P, Wyles CC, Philbrick KA, Ramazanian T, Weston AD, Cai JC, et al. A deep learning tool for automated radiographic measurement of acetabular component inclination and version after total hip arthroplasty. J Arthroplasty. 2021;36(7):2510–7.e6. doi: 10.1016/j.arth.2021.02.026 DOI: https://doi.org/10.1016/j.arth.2021.02.026 Schock J, Truhn D, Abrar DB, Merhof D, Conrad S, Post M, et al. Automated analysis of alignment in long-leg radiographs by using a fully automated support system based on artificial intelligence. Radiol Artif Intell. 2021;3(2):e200198. DOI: https://doi.org/10.1148/ryai.2020200198 Lambrechts A, Ganapathi M, Wirix-Speetjens R. Clinical Evaluation of Artificial Intelligence-based Preoperative Plans for Total Knee Arthroplasty. CAOS 2020 - The 20th Annual Meeting of the International Society for Computer Assisted Orthopedic Surgery: EasyChair; 2020;169–73. Li Z, Zhang X, Ding L, Du K, Yan J, Chan MTV, et al. Deep learning approach for guiding three-dimensional computed tomography reconstruction of lower limbs for robotically-assisted total knee arthroplasty. Int J Med Robot. 2021;17(5):e2300. doi: 10.1002/rcs.2300. DOI: https://doi.org/10.1002/rcs.2300 Jacofsky DJ, Allen M. Robotics in Arthroplasty: A Comprehensive Review. J Arthroplasty. 2016;31(10):2353–63. doi: 10.1016/j.arth.2016.05.026 DOI: https://doi.org/10.1016/j.arth.2016.05.026 Oh S, Kim JH, Choi SW, Lee HJ, Hong J, Kwon SH. Physician Confidence in Artificial Intelligence: An Online Mobile Survey J Med Internet Res. 2019;21(3):e12422. DOI: https://doi.org/10.2196/12422 Inkster B, Sarda S, Subramanian V. An empathy-driven, conversational artificial intelligence agent (Wysa) for digital mental well-being: real-world data evaluation mixed-methods study. JMIR Mhealth Uhealth. 2018;23;6(11):e12106. doi: 10.2196/12106 DOI: https://doi.org/10.2196/12106 Krittanawong C. The rise of artificial intelligence and the uncertain future for physicians. Eur J Intern Med. 2018;48:e13-4. doi: 10.1016/j.ejim.2017.06.017 DOI: https://doi.org/10.1016/j.ejim.2017.06.017 Sarwar S, Dent A, Faust K, Richer M, Djuric U, Ommeren RV, et al. Physician perspectives on integration of artificial intelligence into diagnostic pathology. NPJ Digit Med. 2019;2:28. doi: 10.1038/s41746-019-0106-0 DOI: https://doi.org/10.1038/s41746-019-0106-0 Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A. Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am. 1994;25(3):425-65. DOI: https://doi.org/10.1016/S0030-5898(20)31927-1 Tsafnat G, Glasziou P, Choong MK, Dunn A, Galgani F, Coiera E. Systematic review automation technologies. Systematic Reviews. 2014;3:1–15. DOI: https://doi.org/10.1186/2046-4053-3-74 Federer SJ, Jones GG. Artificial intelligence in orthopedics: A scoping review. PLoS ONE. 2021;16(11): e0260471. doi: 10.1371/journal.pone.0260471 DOI: https://doi.org/10.1371/journal.pone.0260471 Kim DH, MacKinnon T. Artificial intelligence in fracture detection: transfer learning from deep convolutional neural networks. Clin Radiol. 2018;73(5):439–45. doi: 10.1016/j.crad.2017.11.015 DOI: https://doi.org/10.1016/j.crad.2017.11.015 Olczak J, Fahlberg N, Maki A, Razavian AS, Jilert A, Stark A, et al. Artificial intelligence for analyzing orthopedic trauma radiographs Deep learning algorithms-are they on par with humans for diagnosing fractures? Acta Orthopedica. 2017;88(6):581–6. doi: 10.1080/17453674.2017.1344459 DOI: https://doi.org/10.1080/17453674.2017.1344459 Chung SW, Han SS, Lee JW, Oh KS, Kim NR, Yoon JP, et al. Automated detection and classification of the proximal humerus fracture by using deep learning algorithm. Acta Orthop. 2018;89(4):468–73. doi: 10.1080/17453674.2018.1453714 DOI: https://doi.org/10.1080/17453674.2018.1453714 Gan KF, Xu DL, Lin YM, Shen Y, Zhang T, Hu K, et al. Artificial intelligence detection of distal radius fractures: a comparison between the convolutional neural network and professional assessments. Acta Orthopedica. 2019;90(4):394–400. doi: 10.1080/17453674.2019.1600125 DOI: https://doi.org/10.1080/17453674.2019.1600125 Langerhuizen DWG, Janssen SJ, Mallee WH, Van Den Bekerom MPJ, Ring D, Karkhoffs GMMJ, et al. What Are the Applications and Limitations of Artificial Intelligence for Fracture Detection and Classification in Orthopedic Trauma Imaging? A Systematic Review. Clin Orthop Relat Res. 2019; 477(11):2482-91. doi: 10.1097/CORR.0000000000000848 DOI: https://doi.org/10.1097/CORR.0000000000000848 Liang S, Tang F, Huang X, Yang K, Zhong T, Hu R, et al. Deep-learning-based detection and segmentation of organs at risk in nasopharyngeal carcinoma computed tomographic images for radiotherapy planning. Eur Radiol. 2019;29(4):1961–7. doi: 10.1007/s00330-018-5748-9 DOI: https://doi.org/10.1007/s00330-018-5748-9 Wong K, Gallant F, Szumacher E. Perceptions of Canadian radiation oncologists, radiation physicists, radiation therapists and radiation trainees about the impact of artificial intelligence in radiation oncology–national survey. J Med Imaging Radiat Sci. 2021;52(1):44–8. doi: 10.1016/j.jmir.2020.11.013 DOI: https://doi.org/10.1016/j.jmir.2020.11.013 Abdullah R, Fakieh B. Health Care Employees' Perceptions of the Use of Artificial Intelligence Applications: Survey Study. J Med Internet Res. 2020;22(5):e17620. doi: 10.2196/17620 DOI: https://doi.org/10.2196/17620 Sit C, Srinivasan R, Amlani A, Muthuswamy K, Azam A, Monzon L, et al. Attitudes and perceptions of UK medical students towards artificial intelligence and radiology: a multicentre survey. Insights Imaging. 2020;11:14. doi: 10.1186/s13244-019-0830-7 DOI: https://doi.org/10.1186/s13244-019-0830-7 Copyright (c) 2023 Ertuğrul Şahin , Haluk Berk This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

11 July 2025 in Medicine
Verified
Journal Article
Open access
ESErtugrul Sahin
Ertugrul Sahin
SASelahaddin Aydemir
Selahaddin Aydemir
TÇTuğçe Çeltik
Tuğçe Çeltik
Torticollis is a neuromuscular condition characterized by abnormal head posture due to cervical muscle contracture, encompassing both congenital and acquired forms. Although frequently encountered in clinical settings, no prior bibliometric study has comprehensively examined the structure and evolution of torticollis research. This study aimed to map the global literature, identify research hotspots, and highlight influential contributors, institutions, and sources. A bibliometric analysis was performed using the Web of Science Core Collection, covering publications from January 1, 2000 to December 31, 2024. The topic keyword “torticollis” was used to retrieve relevant articles and reviews published in English. VOSviewer, Bibliometrix, and CiteSpace were employed for analyzing co-authorship, keyword co-occurrence, co-citation networks, and citation bursts. Thematic clusters were identified using log-likelihood ratio algorithms, and citation quality was assessed using Silhouette scores. Out of 2825 initial records, 2324 met the inclusion criteria, comprising 1922 articles and 297 reviews. Publication output steadily increased, peaking between 2018 and 2021, with a slight decrease in subsequent years. The United States led in total publications and international collaboration, followed by Germany, China, and the UK. “Movement Disorders” was the most productive and cited journal. Analysis revealed 2 dominant themes: (1) neurologic research on cervical dystonia and botulinum toxin, and (2) pediatric studies on congenital muscular torticollis emphasizing physiotherapy and ultrasound. Emerging keywords such as “clinical practice guideline” and “physical therapy” suggest growing interest in standardizing noninvasive care. Influential authors included J. Jankovic, H.A. Jinnah, and leading institutions such as Emory University and Baylor College of Medicine. Torticollis research is expanding across interdisciplinary lines, driven by both neurologic and pediatric–orthopedic interests. While earlier work centered on neurotherapeutics, recent trends emphasize early diagnosis and conservative management. Greater emphasis on collaboration and evidence-based guidelines will be key to addressing the multifaceted nature of torticollis moving forward.

30 June 2021 in Irish Journal of Medical Science (1971 -)
Verified
Journal Article
Closed access
PDF file
ESErtugrul Sahin
Ertugrul Sahin

27 March 2023 in Journal of Health Sciences and Medicine
Verified
Journal Article
Open access
PDF file
ESErtugrul Sahin
Ertugrul Sahin
MVMustafa Vezi̇rhüyük
Mustafa Vezi̇rhüyük
Aim: Robotic technology has been used to decrease soft tissue dissection and improve postoperative rehabilitation in several areas and robotic-assisted knee replacement has gained popularity last decades. Youtube has an uncontrolled source, making it difficult to verify the correctness of its process. It is critical to assess what they include. This study aimed to assess the quality of the YouTube video content related to robotic-assisted knee replacement surgeries Material and Method: We conducted a search on YouTube using the keywords “robotic-assisted knee replacement”. The headings of the first 50 videos on YouTube were obtained and simultaneously evaluated by two orthopedic surgeons.. We analyzed the general features and categorized videos according to content. The videos were evaluated by using the DISCERN and JAMA scores. Results: 37 videos were included. Twenty-three videos contained total knee replacement surgery while fourteen consisted of unicondylar prosthesis system. The content of the videos included 51.4% (n=19) interviews, 16.2% (n=6) live surgery, 13.5% (n=5) patient testimonials, 8.1% (n=3) animation and presentation-lesson, and 2.7% (n=1) model81.1% of the videos were uploaded by hospital accounts. These were followed by health channels (8.1%), firms (5.4%), doctors (2.7%), and patients (2.7%) the average DISCERN score was 40.1±9.4 and the average JAMA score was 2.2±1 Conclusion: The quality of the information in videos on robotic-assisted knee replacement surgery is poor, YouTube is not currently an appropriate source of such information for patients and there appears to be a disproportionate amount of information focusing on robotic-assisted knee replacement surgery.