In this study, the biomechanical differences among three internal fixation configurations for treatment of Pauwels type II and III femoral neck fractures were analyzed. Using finite element analysis, the femur displacement and stress distributions of the internal fixation device and fracture section were obtained for different patients and movement conditions. The results show that patients with osteoporosis are more prone to femoral varus and femoral neck shortening, and the fracture probability of the device for these patients is higher than that for patients with normal bone. The treatment effect of the inverted-triangle screw (ITS) fixation and proximal femoral nail anti-rotation (PFNA) fixation is better than that of dynamic hip screw (DHS) fixation. The ITS fixation is more suitable for the treatment of the normal bone patients with Pauwels II femur neck fracture. However, the PFNA fixation has better biomechanical advantages and better capability for anti-femoral neck shortening. Therefore, it is suitable for the treatment of femoral neck fracture patients with osteoporosis.
30 September 2023 in Perioperative Precision Medicine
Deep learning, especially graph convolutional networks (GCNs), has been widely applied in various scenarios. Particularly in the field of medical image processing, the research on GCNs have continued to make breakthroughs and has been successfully applied to various tasks, such as medical image segmentation, as well as disease detection, localization, classification and diagnosis. GCNs have demonstrated the capacity to autonomously learn latent disease features from vast medical image datasets. Their potential value and enhanced capabilities in prediction, analysis, and decision-making in perioperative medical imaging have become evident. In recent years, GCNs have rapidly emerged as a research focus in the realm of medical image analysis. First, this review provides a concise overview of the development from convolutional neural networks to GCNs, delineating their algorithmic foundations and network structures. Subsequently, the diverse applications of GCNs in perioperative medical image processing are extensively reviewed, including medical image segmentation, image reconstruction, disease prediction, lesion detection and localization, disease classification and diagnosis, and surgical intervention. Finally, this review discusses the prevailing challenges and offers insights into future research directions for the utilization of GCN methods in the medical field.
Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two ADS1299 chips, and one STM32F303-based microcontroller unit (MCU). This new cECG system could acquire, save, and display the ECG data in real time. The bias feedback as a critical technique was routed to the left hand with the wet Ag/AgCl electrode, which could greatly suppress the power line noise. After all artifacts were removed, the ECG signals could be discerned clearly. We demonstrated that the ECG signals acquired with the capacitive electrodes were similar to those with the wet electrode. Thus, we successfully provide a new configuration for cECG monitoring at home or in a clinical setting.
20 July 2021 in Polymers for Advanced Technologies
When braided dense-mesh stents are used to treat carotid stenosis, the structural mechanics of vascular stents, the contact mechanics with blood vessels, and the fluid mechanics in the blood environment need to be studied in depth to reduce the damage of stents to blood vessels and the incidence of in-stent restenosis. Three types of braided stents with 8, 16, and 24 strands and laser-cut stents with the corresponding size parameters were designed, and the bending behavior of each of these types of stent, deployment, and fluid dynamic analysis of the 24-strand braided stent were simulated. The results show that the bending stress of the 8-, 16-, and 24-strand braided stents is 46.33%, 50.24%, and 31.86% of that of their laser-cut counterparts. In addition, higher strand density of the braided stents was associated with greater bending stress; after the 24-strand braided stent was expanded within the stented carotid artery, the carotid stenosis rate was reduced from 81.52% to 46.33%. After stent implantation, the maximum stress on the vessel wall in a zero-pressure diastolic environment decreased from 0.34 to 0.20 MPa, the maximum pressure on the intravascular wall surface decreased from 4.89 to 3.98 kPa, the area of high-pressure region decreased, the wall shear force of the stenotic segment throat decreased, and blood flow increased in the stenosis segments. The braided stent had less bending stress and better flexibility than the laser-cut stent under the same stent size parameters; after the 24-strand braided stent was implanted into the stented vessel, it could effectively dilate the vessel, and the blood flow status was improved.