Chia-Yen Yang

Prof. Chia-Yen Yang

Department of Biomedical Engineering, Chung Yuan Christian University, Taoyuan City, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2016 in Scientific Reports
Verified
Journal Article
Open access
Cihun-Siyong Alex GongCihun-Siyong Alex Gong
Cihun-Siyong Alex Gong
YLYu-Chen Lee
Yu-Chen Lee
JLJyun-Liang Lai
Jyun-Liang Lai
CYChueh-Hao Yu
Chueh-Hao Yu
LHLi Ren Huang
Li Ren Huang
CYChia-Yen Yang
Chia-Yen Yang
This paper presents a LED driver for VLC. The main purpose is to solve the low data rate problem used to be in switching type LED driver. The GaN power device is proposed to replace the traditional silicon power device of switching LED driver for the purpose of increasing switching frequency of converter, thereby increasing the bandwidth of data transmission. To achieve high efficiency, the diode-connected GaN power transistor is utilized to replace the traditional ultrafast recovery diode used to be in switching type LED driver. This work has been experimentally evaluated on 350-mA output current. The results demonstrate that it supports the data of PWM dimming level encoded in the PPM scheme for VLC application. The experimental results also show that system’s efficiency of 80.8% can be achieved at 1-Mb/s data rate.

23 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CYChia-Yen Yang
Chia-Yen Yang
PCPin-Chen Chen
Pin-Chen Chen
WHWen-Chen Huang
Wen-Chen Huang
Electroencephalography (EEG) is often used to evaluate several types of neurological brain disorders because of its noninvasive and high temporal resolution. In contrast to electrocardiography (ECG), EEG can be uncomfortable and inconvenient for patients. Moreover, deep-learning techniques require a large dataset and a long time for training from scratch. Therefore, in this study, EEG–EEG or EEG–ECG transfer learning strategies were applied to explore their effectiveness for the training of simple cross-domain convolutional neural networks (CNNs) used in seizure prediction and sleep staging systems, respectively. The seizure model detected interictal and preictal periods, whereas the sleep staging model classified signals into five stages. The patient-specific seizure prediction model with six frozen layers achieved 100% accuracy for seven out of nine patients and required only 40 s of training time for personalization. Moreover, the cross-signal transfer learning EEG–ECG model for sleep staging achieved an accuracy approximately 2.5% higher than that of the ECG model; additionally, the training time was reduced by >50%. In summary, transfer learning from an EEG model to produce personalized models for a more convenient signal can both reduce the training time and increase the accuracy; moreover, challenges such as data insufficiency, variability, and inefficiency can be effectively overcome.

12 April 2022 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
CYChia-Yen Yang
Chia-Yen Yang
YHYing-Zu Huang
Ying-Zu Huang

1 June 2020 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
CYChia-Yen Yang
Chia-Yen Yang
CLChing-Po Lin
Ching-Po Lin
Objective : Cognitive reserve (CR) refers to the capacity of the brain to actively cope with damage via the implementation of remedial cognitive processes. Traditional CR measurements focus on static proxies, which may not be able to appropriately estimate dynamic changes in CR. This study therefore investigated the cognitive performance and characteristics of brain activity of low- and high-CR healthy adults during resting and n -back task states and categorized subjects according to magnetoencephalographic (MEG) information using a support vector machine (SVM) classifier. Approach : Forty-one volunteers were divided into groups with low and high CR indexes based on their education, occupational attainment, leisure and social activities. Main results : The results can be summarized as follows. First, subjects with a higher CR had higher accuracies and faster reaction times in the task. Second, subjects with a lower CR had a higher M300 intensity but a constant M300 latency. Third, subjects with a higher CR had a higher beta intensity in the parietal and occipital regions during the task, whereas subjects with a higher CR had a higher gamma intensity in the right temporal region in the resting state. Finally, subjects with a higher CR had negative gamma asymmetry between the right and left occipital regions, whereas subjects with a lower CR had positive values in the resting state. Significance : These MEG results were subsequently used to classify subjects into high-/low-CR subjects using an SVM classifier, and a mean accuracy of 88.89% was obtained. This objective and nonstatic method for determining CR level warrants further research for a wider variety of future clinical applications.

28 May 2015 in Sensors
Verified
Journal Article
Open access
PDF file
Cihun-Siyong Alex GongCihun-Siyong Alex Gong
Cihun-Siyong Alex Gong
HLHSIN-YI LAI
HSIN-YI LAI
SHSy-Han Huang
Sy-Han Huang
YLYu-Chun Lo
Yu-Chun Lo
NLNicole Lee
Nicole Lee
YCYou-Yin Chen
You-Yin Chen
Deep brain stimulation (DBS) is one of the most effective therapies for movement and other disorders. The DBS neurosurgical procedure involves the implantation of a DBS device and a battery-operated neurotransmitter, which delivers electrical impulses to treatment targets through implanted electrodes. The DBS modulates the neuronal activities in the brain nucleus for improving physiological responses as long as an electric discharge above the stimulation threshold can be achieved. In an effort to improve the performance of an implanted DBS device, the device size, implementation cost, and power efficiency are among the most important DBS device design aspects. This study aims to present preliminary research results of an efficient stimulator, with emphasis on conversion efficiency. The prototype stimulator features high-voltage compliance, implemented with only a standard semiconductor process, without the use of extra masks in the foundry through our proposed circuit structure. The results of animal experiments, including evaluation of evoked responses induced by thalamic electrical stimuli with our fabricated chip, were shown to demonstrate the proof of concept of our design.

12 September 2012 in Chemosensory Perception
Verified
Journal Article
Closed access
PDF file
CWChi-Hsun Wu
Chi-Hsun Wu
Po-Lei LeePo-Lei Lee
Po-Lei Lee
CSChih-Hung Shu
Chih-Hung Shu
CYChia-Yen Yang
Chia-Yen Yang
Men-Tzung LoMen-Tzung Lo
Men-Tzung Lo
JHJen-Chuen Hsieh
Jen-Chuen Hsieh