Iris Wiederstein-Grasser

Dr. Iris Wiederstein-Grasser


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
PSPhilipp Stiegler
Philipp Stiegler
MSMichael Sereinigg
Michael Sereinigg
APAndreas Puntschart
Andreas Puntschart
ABAndrea Bradatsch
Andrea Bradatsch
TSThomas Seifert-Held
Thomas Seifert-Held
Vanessa StadlbauerVanessa Stadlbauer
Vanessa Stadlbauer
As organ shortage is increasing, the acceptance of marginal donors increases, which might result in poor organ function and patient survival. Mostly, organ damage is caused during brain death (BD), cold ischemic time (CIT) or after reperfusion due to oxidative stress or the induction of apoptosis. The aim of this study was to study a panel of genes involved in oxidative stress and apoptosis and compare these findings with immunohistochemistry from a BD and living donation (LD) pig model and after cold ischemia time (CIT).

Verified
Journal Article
Open access
PDF file
JTJosip Tomić
Josip Tomić
IWIris Wiederstein-Grasser
Iris Wiederstein-Grasser
MSMonika Schanbacher
Monika Schanbacher
Annelie-Martina WeinbergAnnelie-Martina Weinberg
Annelie-Martina Weinberg
Background: orbital floor fractures have not been reconstructed using magnesium biomaterials. Methods: To test technical feasibility, ex vivo caprine and ovine heads (n = 5) were used. Head tissues were harvested from pubescent animals (n = 5; mean age: 3.2 years; mean mass: 26.3 kg) and stored below 11 degrees for 7–10 days. All procedures were performed in a university animal resource facility. Two experienced maxillofacial surgeons performed orbital floor procedures in both orbits of all animals in a step-by-step preplanned dissection. A transconjunctival approach was chosen to repair the orbital floor with three different implants (i.e., magnesium implants; titanium mesh; and polydioxanone or PDO sheets). The position of each implant was evaluated by Cone-beam computed tomography (CBCT). Results: Axial, coronal, and sagittal plane images showed good positioning of the magnesium plates. The magnesium plates had a radiographic visibility similar to that of the PDO sheets but lower than that of the titanium mesh. Conclusions: The prototype design study showed a novel indication for magnesium biomaterials. Further testing of this new biomaterial may lead to the first resorbable biomaterial with good mechanical properties for extensive orbital wall defects.