Manikandan Gurunathan

Dr. Manikandan Gurunathan

Velammal College of Engineering and Technology, Madurai, Tamil Nadu, India, Madurai, India
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
MGManikandan Gurunathan
Manikandan Gurunathan
Rajesh KannaRajesh Kanna
Rajesh Kanna
Dawid TalerDawid Taler
Dawid Taler
Tomasz SobotaTomasz Sobota
Tomasz Sobota
A detailed review was conducted to explore waste cooking oil (WCO) as feedstock for biodiesel. The manuscript highlights the impact on health while using used cooking oil and the scope for revenue generation from WCO. Up to a 20% blend with diesel results in less pollutants, and it does not demand more modifications to the engine. Also, this reduces the country’s import bill. Furthermore, it suggests the scope for alternate sustainable income among rural farmers through a circular economy. Various collection strategies are discussed, a SWOC (strength, weakness, opportunity, and challenges) analysis is presented to aid in understanding different countries’ policies regarding the collection of WCO, and a more suitable method for conversion is pronounced. A techno-economic analysis is presented to explore the viability of producing 1 litre of biodiesel. The cost of 1 litre of WCO-based biodiesel is compared with costs Iran and Pakistan, and it is noticed that the difference among them is less than 1%. Life cycle assessment (LCA) is mandatory to reveal the impact of WCO biodiesel on socio-economic and environmental concerns. Including exergy analysis will provide comprehensive information about the production and justification of WCO as a biodiesel.

1 November 2021 in Energy
Verified
Journal Article
Closed access
BKB. Varun Kumar
B. Varun Kumar
MGManikandan Gurunathan
Manikandan Gurunathan
Rajesh KannaRajesh Kanna
Rajesh Kanna

9 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
VKVARUN KUMAR
VARUN KUMAR
MGManikandan Gurunathan
Manikandan Gurunathan
Rajesh KannaRajesh Kanna
Rajesh Kanna
Dawid TalerDawid Taler
Dawid Taler
Jan TalerJan Taler
Jan Taler
HTHoong Thiam Toh
Hoong Thiam Toh
In this paper, the effect of various shapes of ribs used in Solar Air Heaters (SAHs) was discussed. The review is concentrated on the geometry of the rib and its location on the SAH panel. Both numerical and experimental works were considered for discussion with dry air and Nano fluids as a working fluid. The influence of various shapes, such as an L shape, W shape, V shape, Multiple V shape, V shape with a gap, detachable & attachable ribs etc., was analyzed. The common fact observed from this analysis is that the implementation of artificial roughness in the absorber plate results in a considerable increase in the rate of heat transfer. Further, it is observed that ‘Multiple V-shaped with open between the ribs’ results in the maximum thermal enhancement when compared to the other shapes.

30 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
VKVARUN KUMAR
VARUN KUMAR
Rajesh KannaRajesh Kanna
Rajesh Kanna
MGManikandan Gurunathan
Manikandan Gurunathan
Dawid TalerDawid Taler
Dawid Taler
Jan TalerJan Taler
Jan Taler
MNMarzena Nowak-Ocłoń
Marzena Nowak-Ocłoń
This research investigates the fluid flow characterization and thermohydraulic performances (THP) of rib surfaces, using computational and experimental methods. ANSYS computational fluid dynamics (CFD) software was used to predict and validate the findings in the experimental setup. Artificial rib surfaces, including polygonal and forward trapezoidal-shaped ribs, were placed in the absorber plate at different relative pitch distances (p/e) = 6.7, 10, 13.4 and relative height (e/d) = 20, and the mass flow rate of air (working fluid) varied at Reynolds numbers ranging from 2000 to 20,000. According to the validation results, the RNG renormalization k-ε model was selected for the investigation. The results show that strong turbulence occured closer to the wall surface and behind the rib surface, enhancing thermal performances due to the sharp edge shape of the rib. A polygonal rib with a pitch distance of p/e = 6.7 achieved a higher Nusselt number (Nu) and thermohydraulic performance of 2.95 at Re 4000. An empirical correlation between the Nusselt number (Nu) and friction factor (f) was developed using linear regression analysis and was compared with the predicted values. The comparison results show a close range of ±8% between the experimental and predicted values.

1 January 2022 in Thermal Science
Verified
Journal Article
Open access
PDF file
VKVARUN KUMAR
VARUN KUMAR
MGManikandan Gurunathan
Manikandan Gurunathan
RPRajesh Parthasarathy
Rajesh Parthasarathy
VPVenkata Reddy Poluru
Venkata Reddy Poluru
Heat transfer enhancement in solar air heater has been investigated by implementing rough surfaces in the absorber plate. We use paraffin wax is used as phase change material integrated with solar air heater as a thermal energy storage system. A maximum convective heat transfer is attained during the daytime and retained as latent heat to discharge heat during OFF radiation. In this investigation, two types of absorber plates were employed such as flat and polygonal-shaped ribs at the test section. Further to investigate the heat transfer enhancement, the research was conducted with and without phase change material. The study was carried out at the mass-flow rates of 0.062 kg/s, 0.028 kg/s, and 0.01 kg/s to ascertain the enhancement of thermal efficiency and heat discharge duration. The temperatures of absorber plate, Tp, ambient Tamb, outlet, Tout, and phase change material along with solar intensity, I [Wm?2], were taken as the main parameters. The research reveals that the absorber plate with polygonal ribs tested with phase change material yields a higher temperature of 77?C with a mass-flow rate of 0.062 kg/s during peak radiation. Discharged heat energy from phase change material to absorber plate for 3.5 hours with a maximum temperature of 7.1?C.

27 December 2012
Verified
Book Chapter
Closed access
PDF file
MMM. Maran
M. Maran
MGManikandan Gurunathan
Manikandan Gurunathan
KTK. Thiagarajan
K. Thiagarajan